Rohan Mudkavi, Tatyana Sarnecki, Ei Ei Phyu, Htet Phyo Than, Veronica Phillips, Naeem Ahmad, Smriti Agarwal, Yogish Joshi, Dilina Rajapakse, Abhishekh H Ashok
{"title":"Cerebral fat embolism treated with mechanical embolectomy: case report and systematic review of the literature.","authors":"Rohan Mudkavi, Tatyana Sarnecki, Ei Ei Phyu, Htet Phyo Than, Veronica Phillips, Naeem Ahmad, Smriti Agarwal, Yogish Joshi, Dilina Rajapakse, Abhishekh H Ashok","doi":"10.1093/bjrcr/uaag019","DOIUrl":null,"url":null,"abstract":"<p><p>Cerebral fat embolism (CFE) is a rare complication of orthopaedic, cardiac and plastic surgery and major trauma. Mechanical embolectomy has been used as a treatment option for this condition. Here, we described a case report of an elderly woman who developed CFE after a total hip replacement which was treated with mechanical embolectomy with aspiration alone. The patient developed left-sided hemiparesis and abnormal posturing after surgery and a CT angiogram 45 minutes later showed a right M1 embolus with fat attenuation. Mechanical embolectomy with aspiration was conducted to produce a TICI score of 3. No patent foramen ovale (PFO) was found to explain the paradoxical embolism. Subsequently, a systematic literature review on the use of mechanical embolectomy for CFE was conducted, with the databases Medline, Web of Science, Embase, Cinahl, and Scopus being searched. The review found 20 cases, 13 of which were treated with aspiration and a stent retriever, and 5 of which were treated with aspiration only. A reduced mortality was observed in the aspiration only cohort compared to the aspiration plus stent retriever cohort, despite both groups having similar age and gender. Among patients treated with stenting, 3 out of 13 (23%) died, compared to 0 out of 5 (0%) patients treated with aspiration alone. Although this difference was not statistically significant, it may reflect a trend worth further exploration, potentially limited by the small sample size. Further registry-based studies and preclinical models are required to elucidate the effectiveness and superior technique of mechanical embolectomy for CFE.</p>","PeriodicalId":45216,"journal":{"name":"BJR Case Reports","volume":"12 3","pages":"uaag019"},"PeriodicalIF":0.6000,"publicationDate":"2026-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13198375/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BJR Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/bjrcr/uaag019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Cerebral fat embolism (CFE) is a rare complication of orthopaedic, cardiac and plastic surgery and major trauma. Mechanical embolectomy has been used as a treatment option for this condition. Here, we described a case report of an elderly woman who developed CFE after a total hip replacement which was treated with mechanical embolectomy with aspiration alone. The patient developed left-sided hemiparesis and abnormal posturing after surgery and a CT angiogram 45 minutes later showed a right M1 embolus with fat attenuation. Mechanical embolectomy with aspiration was conducted to produce a TICI score of 3. No patent foramen ovale (PFO) was found to explain the paradoxical embolism. Subsequently, a systematic literature review on the use of mechanical embolectomy for CFE was conducted, with the databases Medline, Web of Science, Embase, Cinahl, and Scopus being searched. The review found 20 cases, 13 of which were treated with aspiration and a stent retriever, and 5 of which were treated with aspiration only. A reduced mortality was observed in the aspiration only cohort compared to the aspiration plus stent retriever cohort, despite both groups having similar age and gender. Among patients treated with stenting, 3 out of 13 (23%) died, compared to 0 out of 5 (0%) patients treated with aspiration alone. Although this difference was not statistically significant, it may reflect a trend worth further exploration, potentially limited by the small sample size. Further registry-based studies and preclinical models are required to elucidate the effectiveness and superior technique of mechanical embolectomy for CFE.
脑脂肪栓塞(CFE)是骨科,心脏和整形外科手术和重大创伤的罕见并发症。机械栓塞切除术已被用作这种情况的治疗选择。在这里,我们描述了一例老年妇女在全髋关节置换术后发生CFE的病例报告,该手术仅采用机械栓塞切除术和吸入术治疗。患者术后出现左侧偏瘫和姿态异常,45分钟后CT血管造影显示右侧M1栓子伴脂肪衰减。机械栓塞穿刺切除,TICI评分为3分。未发现卵圆孔未闭(PFO)可以解释矛盾栓塞。随后,通过检索Medline、Web of Science、Embase、Cinahl、Scopus等数据库,对机械栓塞术治疗CFE的文献进行了系统的综述。回顾发现20例,其中13例采用抽吸和支架取出器治疗,5例仅采用抽吸治疗。尽管两组年龄和性别相似,但仅吸入组的死亡率比吸入加支架取出组的死亡率低。在接受支架治疗的患者中,13人中有3人(23%)死亡,而单独接受抽吸治疗的5人中有0人(0%)死亡。虽然这种差异在统计上并不显著,但它可能反映了一种值得进一步探索的趋势,可能受到小样本量的限制。需要进一步的基于登记的研究和临床前模型来阐明机械栓塞切除术治疗CFE的有效性和优越技术。