Toward next-generation hip implants: From failure mechanisms to translational design

IF 9.8 1区 医学 Q1 ORTHOPEDICS
Journal of Orthopaedic Translation Pub Date : 2026-05-01 Epub Date: 2026-05-17 DOI:10.1016/j.jot.2026.101122
Yunhua Luo , Thomas Turgeon , Ian Polyzois
{"title":"Toward next-generation hip implants: From failure mechanisms to translational design","authors":"Yunhua Luo ,&nbsp;Thomas Turgeon ,&nbsp;Ian Polyzois","doi":"10.1016/j.jot.2026.101122","DOIUrl":null,"url":null,"abstract":"<div><div>Total hip replacement (THR) is highly successful in restoring mobility after hip fracture, yet long-term complications such as aseptic loosening, periprosthetic fracture, wear-induced osteolysis, and stress shielding continue to limit implant longevity. These failure modes largely originate from the inability of monolithic implant designs to satisfy the heterogeneous mechanical and biological requirements of the proximal femur. Their uniform material properties and fixed architecture hinder physiological load transfer, compromise osseointegration, and accelerate bone loss. Functionally graded hip scaffold–implant hybrids (FG-HSIHs) have emerged as a promising next-generation solution, offering spatial control over stiffness, porosity, degradation behavior, and surface bioactivity within a single construct to better mimic the structure and function of healthy bone.</div><div>This review synthesizes advances in clinical understanding, biomechanics, mechanobiology, and computational modeling relevant to the development of FG-HSIHs. We first examine the biological pathways and biomechanical mechanisms underlying major THR complications, highlighting the inherent conflicts among desired material and structural properties. These mechanistic insights form the basis for simulation-guided strategies that enable spatially adaptive design tailored to mitigate specific failure risks. We then evaluate current progress in mechanical modeling, mechanobiological simulation, multiphysics analysis, and multi-objective optimization, and assess how these components contribute to an integrated design workflow. Despite rapid progress, no existing framework fully unifies mechanical, biological, transport, and degradation processes or incorporates patient-specific biological factors. Key challenges remain in defining physiologically grounded grading targets, establishing predictive validation pipelines, and implementing multiphysics-driven design tools suitable for translational use. Overall, the purpose of this review is to assemble a coherent, field-wide perspective on the clinical, biomechanical, biological, and computational considerations relevant to FG-HSIH design, rather than cataloging all technical details.</div></div><div><h3>Translational potential of this article</h3><div>The framework presented in this review provides a structured pathway for translating functionally graded hip scaffold–implant hybrids from concept to clinically testable prototypes. By linking THR failure mechanisms with biomechanical requirements, biological pathways, and computational design strategies, the review identifies actionable targets for implant innovation and preclinical development. The synthesis of mechanical modeling, mechanobiology, and multiphysics optimization offers a roadmap for generating designs that more effectively integrate with host bone and reduce long-term revision risk. The identified translational gaps—including the lack of integrated mechanobiological–degradation models, limited patient-specific biological inputs, and insufficient validation pipelines—clarify priorities for future experimental studies, preclinical testing protocols, and multidisciplinary collaboration. Collectively, these insights support the development of next-generation hip implants that can improve long-term patient outcomes and reduce the burden of revision surgery.</div></div>","PeriodicalId":16636,"journal":{"name":"Journal of Orthopaedic Translation","volume":"58 ","pages":"Article 101122"},"PeriodicalIF":9.8000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Translation","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214031X26000781","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Total hip replacement (THR) is highly successful in restoring mobility after hip fracture, yet long-term complications such as aseptic loosening, periprosthetic fracture, wear-induced osteolysis, and stress shielding continue to limit implant longevity. These failure modes largely originate from the inability of monolithic implant designs to satisfy the heterogeneous mechanical and biological requirements of the proximal femur. Their uniform material properties and fixed architecture hinder physiological load transfer, compromise osseointegration, and accelerate bone loss. Functionally graded hip scaffold–implant hybrids (FG-HSIHs) have emerged as a promising next-generation solution, offering spatial control over stiffness, porosity, degradation behavior, and surface bioactivity within a single construct to better mimic the structure and function of healthy bone.
This review synthesizes advances in clinical understanding, biomechanics, mechanobiology, and computational modeling relevant to the development of FG-HSIHs. We first examine the biological pathways and biomechanical mechanisms underlying major THR complications, highlighting the inherent conflicts among desired material and structural properties. These mechanistic insights form the basis for simulation-guided strategies that enable spatially adaptive design tailored to mitigate specific failure risks. We then evaluate current progress in mechanical modeling, mechanobiological simulation, multiphysics analysis, and multi-objective optimization, and assess how these components contribute to an integrated design workflow. Despite rapid progress, no existing framework fully unifies mechanical, biological, transport, and degradation processes or incorporates patient-specific biological factors. Key challenges remain in defining physiologically grounded grading targets, establishing predictive validation pipelines, and implementing multiphysics-driven design tools suitable for translational use. Overall, the purpose of this review is to assemble a coherent, field-wide perspective on the clinical, biomechanical, biological, and computational considerations relevant to FG-HSIH design, rather than cataloging all technical details.

Translational potential of this article

The framework presented in this review provides a structured pathway for translating functionally graded hip scaffold–implant hybrids from concept to clinically testable prototypes. By linking THR failure mechanisms with biomechanical requirements, biological pathways, and computational design strategies, the review identifies actionable targets for implant innovation and preclinical development. The synthesis of mechanical modeling, mechanobiology, and multiphysics optimization offers a roadmap for generating designs that more effectively integrate with host bone and reduce long-term revision risk. The identified translational gaps—including the lack of integrated mechanobiological–degradation models, limited patient-specific biological inputs, and insufficient validation pipelines—clarify priorities for future experimental studies, preclinical testing protocols, and multidisciplinary collaboration. Collectively, these insights support the development of next-generation hip implants that can improve long-term patient outcomes and reduce the burden of revision surgery.

Abstract Image

迈向下一代髋关节植入物:从失效机制到转化设计
全髋关节置换术(THR)在髋部骨折后恢复活动能力方面非常成功,但无菌性松动、假体周围骨折、磨损性骨溶解和应力屏蔽等长期并发症继续限制假体的使用寿命。这些失效模式很大程度上源于单片植入体设计无法满足股骨近端不同的力学和生物学要求。其均匀的材料特性和固定的结构阻碍了生理负荷转移,损害了骨整合,加速了骨质流失。功能分级髋关节支架-植入物杂交体(FG-HSIHs)已成为一种有前景的下一代解决方案,在单一结构中提供对刚度、孔隙度、降解行为和表面生物活性的空间控制,以更好地模拟健康骨骼的结构和功能。本文综述了FG-HSIHs在临床理解、生物力学、力学生物学和计算建模方面的进展。我们首先研究了主要THR并发症的生物学途径和生物力学机制,强调了所需材料和结构特性之间的内在冲突。这些机制见解形成了仿真指导策略的基础,使空间自适应设计能够量身定制,以减轻特定的故障风险。然后,我们评估了机械建模、机械生物学仿真、多物理场分析和多目标优化方面的最新进展,并评估了这些组件如何有助于集成设计工作流。尽管进展迅速,但现有的框架尚未完全统一机械、生物、运输和降解过程,或纳入患者特异性生物因素。关键的挑战仍然是定义基于生理学的分级目标,建立预测验证管道,以及实现适合转译使用的多物理场驱动的设计工具。总的来说,这篇综述的目的是对FG-HSIH设计相关的临床、生物力学、生物学和计算方面的考虑进行连贯的、广泛的研究,而不是对所有的技术细节进行编目。这篇综述中提出的框架为将功能分级的髋关节支架-植入物混合物从概念转化为临床可测试的原型提供了一个结构化的途径。通过将THR失效机制与生物力学要求、生物学途径和计算设计策略联系起来,该综述确定了植入物创新和临床前开发的可操作目标。机械建模、机械生物学和多物理场优化的综合为生成更有效地与宿主骨整合并降低长期翻修风险的设计提供了路线图。已确定的转化缺口——包括缺乏集成的机械生物学降解模型、有限的患者特异性生物输入和不足的验证管道——明确了未来实验研究、临床前测试方案和多学科合作的优先事项。总的来说,这些见解支持下一代髋关节植入物的开发,可以改善患者的长期预后并减轻翻修手术的负担。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Orthopaedic Translation
Journal of Orthopaedic Translation Medicine-Orthopedics and Sports Medicine
CiteScore
11.80
自引率
13.60%
发文量
91
审稿时长
29 days
期刊介绍: The Journal of Orthopaedic Translation (JOT) is the official peer-reviewed, open access journal of the Chinese Speaking Orthopaedic Society (CSOS) and the International Chinese Musculoskeletal Research Society (ICMRS). It is published quarterly, in January, April, July and October, by Elsevier.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书