Transformer-based synthesis of 7 Tesla-like T1 contrast from routine clinical magnetic resonance imaging.

IF 3.2
Medical physics Pub Date : 2026-05-01 DOI:10.1002/mp.70496
Zach Eidex, Mojtaba Safari, Tonghe Wang, David S Yu, Vanessa Wildman, Hui Mao, Erik Middlebrooks, Aparna H Kesarwala, Xiaofeng Yang
{"title":"Transformer-based synthesis of 7 Tesla-like T1 contrast from routine clinical magnetic resonance imaging.","authors":"Zach Eidex, Mojtaba Safari, Tonghe Wang, David S Yu, Vanessa Wildman, Hui Mao, Erik Middlebrooks, Aparna H Kesarwala, Xiaofeng Yang","doi":"10.1002/mp.70496","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ultra-high-field 7 Tesla (7T) magnetic resonance imaging (MRI) provides improved resolution and signal-to-noise ratio (SNR) over standard clinical field strengths (1.5T, 3T). However, 7T scanners are costly, scarce, and introduce additional challenges such as susceptibility artifacts.</p><p><strong>Purpose: </strong>We propose an efficient transformer-based model (7T-Restormer) to synthesize 7T-like MRI (quantitative T1 MP2RAGE maps) from routine 1.5T or 3T T1-weighted (T1W) images.</p><p><strong>Methods: </strong>The proposed method leverages an efficient restoration transformer backbone and spatial attention layers to capture long-range dependencies and generate high-quality 7T-like images. Our model was validated on an institutional dataset, comprised of 35 1.5T and 108 3T T1w MRI paired with corresponding 7T T1 maps of patients with confirmed multiple sclerosis (MS). A total of 141 patient cases (32 128 slices) were randomly divided into 105 (25 1.5T and 80 3T) training cases (19 204 slices), 19 (5 1.5T and 14 3T) validation cases (3476 slices), and 17 (5 1.5T and 12 3T) test cases (3145 slices). The synthetic 7T T1 maps were evaluated by comparing their similarity to the ground truth volumes using peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), and normalized mean squared error (NMSE), and were compared against ResViT and ResShift. In addition, a blinded reader study was performed in which three clinicians scored the diagnostic image quality of each method on a 5-point Likert scale (1 = non-acceptable, 5 = excellent). Statistical significance (α = 0.05) was assessed using two-sided paired t-tests with Holm correction for multiple comparisons and Wilcoxon signed-rank tests with Holm correction for reader scores. Effect sizes (Cohen's <math> <semantics><msub><mi>d</mi> <mi>z</mi></msub> <annotation>${{d}_z}$</annotation></semantics> </math> for paired data) were also computed to quantify practical significance. We interpreted <math> <semantics><mrow><mo>∣</mo> <msub><mi>d</mi> <mi>z</mi></msub> <mo>∣</mo> <mo>≈</mo> <mn>0.2</mn> <mo>,</mo> <mspace></mspace> <mn>0.5</mn> <mo>,</mo></mrow> <annotation>$\\mid {{d}_z}\\mid \\approx 0.2,\\ 0.5,$</annotation></semantics> </math> and <math> <semantics><mrow><mn>0.8</mn></mrow> <annotation>$0.8$</annotation></semantics> </math> as small, medium, and large effects.</p><p><strong>Results: </strong>For 1.5T inputs, 7T-Restormer achieved an NMSE of 0.018 ± 0.003, PSNR of 25.0 ± 0.6 dB, and SSIM of 0.870 ± 0.019; for 3T inputs, the corresponding values were 0.019 ± 0.006, 24.5 ± 1.2 dB, and 0.874 ± 0.027. Across both field strengths, 7T-Restormer provided the lowest NMSE and highest PSNR and SSIM among the three methods, reducing NMSE by approximately 5% and 25% relative to ResShift and ResViT at 1.5T and by 14% and 24% at 3T, respectively, and increasing PSNR by 0.5-1.5 dB (Holm-adjusted p < 0.05, paired Cohen's <math> <semantics><msub><mi>d</mi> <mi>z</mi></msub> <annotation>${{d}_z}$</annotation></semantics> </math> = 1.37-6.84). Training on mixed 1.5T+3T data improved performance for 1.5T inputs compared with 1.5T-only training (e.g., NMSE 0.018 vs. 0.019; p = 0.001, <math> <semantics> <mrow><msub><mi>d</mi> <mi>z</mi></msub> <mo>=</mo> <mo>-</mo> <mn>4.29</mn></mrow> <annotation>${{d}_z} = - 4.29$</annotation></semantics> </math> ), without degrading performance for 3T inputs (p = 0.630, <math> <semantics> <mrow><msub><mi>d</mi> <mi>z</mi></msub> <mo>=</mo> <mo>-</mo> <mn>0.14</mn></mrow> <annotation>${{d}_z} = - 0.14$</annotation></semantics> </math> for NMSE). In the blinded reader study, 7T-Restormer received higher diagnostic quality scores (3.50 ± 0.28) than ResShift (3.00 ± 0.27) and ResViT (2.33 ± 0.27), corresponding to mean improvements of 0.5-1.2 points on the 5-point scale (Holm-adjusted p = 0.014 and 0.004; paired Cohen's <math> <semantics> <mrow><msub><mi>d</mi> <mi>z</mi></msub> <mo>=</mo> <mn>1.27</mn></mrow> <annotation>${{d}_z} = 1.27$</annotation></semantics> </math> and 3.24, respectively).</p><p><strong>Conclusion: </strong>We propose a novel method for predicting quantitative 7T MP2RAGE maps from 1.5T and 3T T1W scans with higher quality than existing state-of-the-art methods. Future development and application of our approach may enhance diagnostic accuracy, treatment planning, and facilitate downstream tasks by making the benefits of 7T MRI more accessible to standard clinical workflows.</p>","PeriodicalId":94136,"journal":{"name":"Medical physics","volume":"53 5","pages":"e70496"},"PeriodicalIF":3.2000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/mp.70496","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Ultra-high-field 7 Tesla (7T) magnetic resonance imaging (MRI) provides improved resolution and signal-to-noise ratio (SNR) over standard clinical field strengths (1.5T, 3T). However, 7T scanners are costly, scarce, and introduce additional challenges such as susceptibility artifacts.

Purpose: We propose an efficient transformer-based model (7T-Restormer) to synthesize 7T-like MRI (quantitative T1 MP2RAGE maps) from routine 1.5T or 3T T1-weighted (T1W) images.

Methods: The proposed method leverages an efficient restoration transformer backbone and spatial attention layers to capture long-range dependencies and generate high-quality 7T-like images. Our model was validated on an institutional dataset, comprised of 35 1.5T and 108 3T T1w MRI paired with corresponding 7T T1 maps of patients with confirmed multiple sclerosis (MS). A total of 141 patient cases (32 128 slices) were randomly divided into 105 (25 1.5T and 80 3T) training cases (19 204 slices), 19 (5 1.5T and 14 3T) validation cases (3476 slices), and 17 (5 1.5T and 12 3T) test cases (3145 slices). The synthetic 7T T1 maps were evaluated by comparing their similarity to the ground truth volumes using peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), and normalized mean squared error (NMSE), and were compared against ResViT and ResShift. In addition, a blinded reader study was performed in which three clinicians scored the diagnostic image quality of each method on a 5-point Likert scale (1 = non-acceptable, 5 = excellent). Statistical significance (α = 0.05) was assessed using two-sided paired t-tests with Holm correction for multiple comparisons and Wilcoxon signed-rank tests with Holm correction for reader scores. Effect sizes (Cohen's d z ${{d}_z}$ for paired data) were also computed to quantify practical significance. We interpreted ∣ d z ∣ ≈ 0.2 , 0.5 , $\mid {{d}_z}\mid \approx 0.2,\ 0.5,$ and 0.8 $0.8$ as small, medium, and large effects.

Results: For 1.5T inputs, 7T-Restormer achieved an NMSE of 0.018 ± 0.003, PSNR of 25.0 ± 0.6 dB, and SSIM of 0.870 ± 0.019; for 3T inputs, the corresponding values were 0.019 ± 0.006, 24.5 ± 1.2 dB, and 0.874 ± 0.027. Across both field strengths, 7T-Restormer provided the lowest NMSE and highest PSNR and SSIM among the three methods, reducing NMSE by approximately 5% and 25% relative to ResShift and ResViT at 1.5T and by 14% and 24% at 3T, respectively, and increasing PSNR by 0.5-1.5 dB (Holm-adjusted p < 0.05, paired Cohen's d z ${{d}_z}$ = 1.37-6.84). Training on mixed 1.5T+3T data improved performance for 1.5T inputs compared with 1.5T-only training (e.g., NMSE 0.018 vs. 0.019; p = 0.001, d z = - 4.29 ${{d}_z} = - 4.29$ ), without degrading performance for 3T inputs (p = 0.630, d z = - 0.14 ${{d}_z} = - 0.14$ for NMSE). In the blinded reader study, 7T-Restormer received higher diagnostic quality scores (3.50 ± 0.28) than ResShift (3.00 ± 0.27) and ResViT (2.33 ± 0.27), corresponding to mean improvements of 0.5-1.2 points on the 5-point scale (Holm-adjusted p = 0.014 and 0.004; paired Cohen's d z = 1.27 ${{d}_z} = 1.27$ and 3.24, respectively).

Conclusion: We propose a novel method for predicting quantitative 7T MP2RAGE maps from 1.5T and 3T T1W scans with higher quality than existing state-of-the-art methods. Future development and application of our approach may enhance diagnostic accuracy, treatment planning, and facilitate downstream tasks by making the benefits of 7T MRI more accessible to standard clinical workflows.

基于变压器的7特斯拉样T1对比综合临床常规磁共振成像。
背景:超高场7特斯拉(7T)磁共振成像(MRI)比标准临床场强(1.5T, 3T)提供更高的分辨率和信噪比(SNR)。然而,7T扫描仪价格昂贵,稀缺,并引入了其他挑战,例如易感性工件。目的:我们提出了一种高效的基于变压器的模型(7T-Restormer),从常规的1.5T或3T T1加权(T1W)图像中合成7t样MRI(定量T1 MP2RAGE图)。方法:该方法利用高效的恢复变压器骨干和空间注意层来捕获远程依赖关系并生成高质量的7t样图像。我们的模型在一个机构数据集上得到了验证,该数据集由35个1.5T和108个3T T1w MRI与确诊多发性硬化症(MS)患者的相应7T T1图配对组成。141例患者(32 128片)随机分为105例(25例1.5T和80例3T)训练例(19 204片)、19例(5例1.5T和14例3T)验证例(3476片)和17例(5例1.5T和12例3T)测试例(3145片)。利用峰值信噪比(PSNR)、结构相似性指数(SSIM)和归一化均方误差(NMSE)对合成的7T T1地图与地面真实体积的相似性进行评价,并与ResViT和ResShift进行比较。此外,还进行了一项盲法读者研究,其中三名临床医生对每种方法的诊断图像质量进行了5分李克特评分(1 =不可接受,5 =优秀)。多重比较采用双侧配对t检验,采用Holm校正;读者评分采用Wilcoxon符号秩检验,采用Holm校正,评估统计学意义(α = 0.05)。还计算了效应量(配对数据为Cohen’s d z ${{d}_z}$)以量化实际意义。我们将∣d z∣≈0.2、0.5、$\mid {{d}_z}\mid \approx 0.2,\ 0.5,$和0.8 $0.8$解释为小、中、大效应。结果:对于1.5T输入,7T-Restormer的NMSE为0.018±0.003,PSNR为25.0±0.6 dB, SSIM为0.870±0.019;对于3T输入,对应值分别为0.019±0.006、24.5±1.2 dB和0.874±0.027。在两种电场强度下,7T-Restormer的NMSE最低,PSNR和SSIM最高,NMSE降低了约5%% and 25% relative to ResShift and ResViT at 1.5T and by 14% and 24% at 3T, respectively, and increasing PSNR by 0.5-1.5 dB (Holm-adjusted p  d z ${{d}_z}$ = 1.37-6.84). Training on mixed 1.5T+3T data improved performance for 1.5T inputs compared with 1.5T-only training (e.g., NMSE 0.018 vs. 0.019; p = 0.001, d z = - 4.29 ${{d}_z} = - 4.29$ ), without degrading performance for 3T inputs (p = 0.630, d z = - 0.14 ${{d}_z} = - 0.14$ for NMSE). In the blinded reader study, 7T-Restormer received higher diagnostic quality scores (3.50 ± 0.28) than ResShift (3.00 ± 0.27) and ResViT (2.33 ± 0.27), corresponding to mean improvements of 0.5-1.2 points on the 5-point scale (Holm-adjusted p = 0.014 and 0.004; paired Cohen's d z = 1.27 ${{d}_z} = 1.27$ and 3.24, respectively).Conclusion: We propose a novel method for predicting quantitative 7T MP2RAGE maps from 1.5T and 3T T1W scans with higher quality than existing state-of-the-art methods. Future development and application of our approach may enhance diagnostic accuracy, treatment planning, and facilitate downstream tasks by making the benefits of 7T MRI more accessible to standard clinical workflows.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书