Assessment of different direct printed aligner resins for leaching of urethane dimethacrylate: an in vivo study.

IF 3.2
Aswathi Selvaraj, Deepak Prabhu, Balaji Krishnan, Parameswaran Tm, Mahalakshmi Krishnakumaran, Mohan Kumar
{"title":"Assessment of different direct printed aligner resins for leaching of urethane dimethacrylate: an in vivo study.","authors":"Aswathi Selvaraj, Deepak Prabhu, Balaji Krishnan, Parameswaran Tm, Mahalakshmi Krishnakumaran, Mohan Kumar","doi":"10.2319/092225-788.1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the release of urethane dimethacrylate (UDMA) from the direct printed aligners using Tera Harz TC-85 resin (Graphy, Seoul, Korea) and Clear A resin (Senertek, Türkiye) in saliva samples at different time intervals.</p><p><strong>Materials and methods: </strong>This prospective quasiexperimental study included 2 groups: Group A Tera Harz TC-85 (Graphy, Seoul, Korea) and Group B Clear A resin (Senertek, Izmir, Türkiye), each with 13 participants. Patients wore aligners for more than 20 hours a day for 14 days. Whole saliva samples were obtained at several time intervals: T0 before aligners were inserted and T1, T2, and T3 after 24 hours, 7 days, and 14 days of usage, respectively. High-performance liquid chromatography was used to analyze the samples, and the average results were computed.</p><p><strong>Results: </strong>Results showed significant variations in UDMA leaching between groups A and B at all postintervention periods. Group B had a significantly greater mean UDMA release than Group A at T1, T2, and T3. Intragroup analysis revealed time-dependent increases in UDMA release in both groups.</p><p><strong>Conclusions: </strong>The findings revealed significant differences in UDMA release rates between the two materials, with Tera Harz TC-85 consistently showing lower levels of leaching than Clear A resin over the 14-day study period. Tera Harz TC-85 has superior performance in minimizing UDMA leaching, while both materials maintained acceptable profiles under the study conditions.</p>","PeriodicalId":94224,"journal":{"name":"The Angle orthodontist","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2026-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13692982/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Angle orthodontist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2319/092225-788.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate the release of urethane dimethacrylate (UDMA) from the direct printed aligners using Tera Harz TC-85 resin (Graphy, Seoul, Korea) and Clear A resin (Senertek, Türkiye) in saliva samples at different time intervals.

Materials and methods: This prospective quasiexperimental study included 2 groups: Group A Tera Harz TC-85 (Graphy, Seoul, Korea) and Group B Clear A resin (Senertek, Izmir, Türkiye), each with 13 participants. Patients wore aligners for more than 20 hours a day for 14 days. Whole saliva samples were obtained at several time intervals: T0 before aligners were inserted and T1, T2, and T3 after 24 hours, 7 days, and 14 days of usage, respectively. High-performance liquid chromatography was used to analyze the samples, and the average results were computed.

Results: Results showed significant variations in UDMA leaching between groups A and B at all postintervention periods. Group B had a significantly greater mean UDMA release than Group A at T1, T2, and T3. Intragroup analysis revealed time-dependent increases in UDMA release in both groups.

Conclusions: The findings revealed significant differences in UDMA release rates between the two materials, with Tera Harz TC-85 consistently showing lower levels of leaching than Clear A resin over the 14-day study period. Tera Harz TC-85 has superior performance in minimizing UDMA leaching, while both materials maintained acceptable profiles under the study conditions.

评估不同的直接印刷对准树脂对二甲基丙烯酸氨基甲酸乙酯浸出:一项体内研究。
目的:考察Tera Harz TC-85树脂(Graphy, Seoul, Korea)和Clear A树脂(Senertek, t rkiye)直接打印的对准器在不同时间间隔内对唾液样品中二甲丙烯酸乙酯(UDMA)的释放。材料和方法:本前瞻性准实验研究分为两组:A组Tera Harz TC-85 (Graphy, Seoul, Korea)和B组Clear A resin (Senertek, Izmir, t rkiye),每组13名受试者。患者每天佩戴矫正器超过20小时,持续14天。在插入矫正器前的T0和使用24小时、7天、14天后的T1、T2、T3三个时间间隔采集全唾液样本。采用高效液相色谱法对样品进行分析,计算平均结果。结果:结果显示,在干预后的所有时期,A组和B组之间的UDMA浸出有显著差异。在T1、T2和T3时,B组UDMA平均释放量明显高于a组。组内分析显示两组UDMA释放随时间增加。结论:研究结果揭示了两种材料之间UDMA释放率的显著差异,在14天的研究期间,Tera Harz TC-85始终显示出比Clear A树脂更低的浸出水平。Tera Harz TC-85在减少UDMA浸出方面具有卓越的性能,而两种材料在研究条件下都保持了可接受的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书