{"title":"[Effect of Different Look Up Tables on Contrast Effect in Lower Limb Angiography Using the Frequency Subtraction Method].","authors":"Ryo Sekiguchi, Kazuya Mori, Masato Suzaki","doi":"10.6009/jjrt.26-1630","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to investigate the impact of different look up tables (LUTs) on contrast enhancement in lower extremity angiography using the frequency subtraction method.</p><p><strong>Methods: </strong>A lower extremity vascular phantom was constructed, and contrast medium concentrations of 100%, 75%, 50%, and 25% were prepared. Imaging was performed using the frequency subtraction method, and each image was processed with different LUTs (linear, A, and C). The linear LUT at 100% concentration (linear-100%) served as the control. Contrast was quantified using profile curves, and subjective image quality was assessed by the degradation category rating method.</p><p><strong>Results: </strong>In the central region of the bone, LUT A-100% and C-100% yielded higher contrast values compared with the control. At the bone margins, A-100%, A-75%, and A-50% demonstrated greater contrast enhancement. Subjective evaluation showed that scores for A-50% and C-50% in the central bone region exceeded the tolerance limit. In the cortical bone region, scores for A-75% and C-50% exceeded the acceptable limit.</p><p><strong>Conclusion: </strong>It was demonstrated that appropriate modification of LUTs in the frequency subtraction method contributes to improved contrast enhancement.</p>","PeriodicalId":74309,"journal":{"name":"Nihon Hoshasen Gijutsu Gakkai zasshi","volume":"82 6","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Hoshasen Gijutsu Gakkai zasshi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6009/jjrt.26-1630","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The purpose of this study was to investigate the impact of different look up tables (LUTs) on contrast enhancement in lower extremity angiography using the frequency subtraction method.
Methods: A lower extremity vascular phantom was constructed, and contrast medium concentrations of 100%, 75%, 50%, and 25% were prepared. Imaging was performed using the frequency subtraction method, and each image was processed with different LUTs (linear, A, and C). The linear LUT at 100% concentration (linear-100%) served as the control. Contrast was quantified using profile curves, and subjective image quality was assessed by the degradation category rating method.
Results: In the central region of the bone, LUT A-100% and C-100% yielded higher contrast values compared with the control. At the bone margins, A-100%, A-75%, and A-50% demonstrated greater contrast enhancement. Subjective evaluation showed that scores for A-50% and C-50% in the central bone region exceeded the tolerance limit. In the cortical bone region, scores for A-75% and C-50% exceeded the acceptable limit.
Conclusion: It was demonstrated that appropriate modification of LUTs in the frequency subtraction method contributes to improved contrast enhancement.