Acquisition time/dose reduction in pediatric PET imaging using patch-based deep learning.

IF 3.5 2区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Chenyang Han, Andrew T Trout, Andi Li, Joseph G Meier, Vinicius P V Alves, Joseph MacLean, Nadeen Abu Ata, Yinan Li, Susan E Sharp, Christopher G Anton, Jing Tang
{"title":"Acquisition time/dose reduction in pediatric PET imaging using patch-based deep learning.","authors":"Chenyang Han, Andrew T Trout, Andi Li, Joseph G Meier, Vinicius P V Alves, Joseph MacLean, Nadeen Abu Ata, Yinan Li, Susan E Sharp, Christopher G Anton, Jing Tang","doi":"10.1186/s40658-026-00876-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Deep learning (DL)-based denoising methods have shown promise for reducing radiation dose and/or acquisition time in pediatric PET imaging. However, conventional DL approaches typically require large and diverse training datasets to achieve generalizability. We propose a patch-based DL (PDL) approach that learns local structural representations from a single high-quality examination, with the goal of improving image quality and preserving quantitative accuracy of reduced-count pediatric whole-body PET while minimizing training burden.</p><p><strong>Methods: </strong>This retrospective study included PET/CT datasets acquired on a GE Discovery MI Gen 2 scanner. A single pediatric examination with high structural conspicuity and low noise was used for training. Testing was performed using a NEMA phantom and 88 clinical pediatric examinations (age < 12 years) acquired with routine pediatric FDG dosing and a 90‑s‑per‑bed protocol. Clinical list‑mode data were truncated to 20 s per bed to simulate reduced‑count acquisitions; training and phantom datasets were downsampled to match this noise level. The PDL model was trained using paired full‑count and reduced‑count image patches and applied to denoise reduced‑count phantom and patient images. Phantom evaluations assessed spatial resolution, contrast recovery, and noise. Clinical evaluation included a blinded observer study and quantitative SUV analysis, followed by assessment of the noise-bias tradeoff.</p><p><strong>Results: </strong>PDL preserved spatial resolution and contrast while achieving substantial noise reduction in phantom experiments. In the observer study, PDL‑enhanced 20‑s‑per‑bed images were rated as equivalent or superior in overall image quality and noise relative to standard 90‑s‑per‑bed images in more than 85% of cases. Small negative relative bias in SUV<sub>max</sub> and SUV<sub>mean</sub> was observed in the liver, mediastinal blood pool, and lesions, with no statistically significant differences compared with standard‑count images. Compared with highly regularized reconstruction, PDL achieved greater noise reduction with reduced bias.</p><p><strong>Conclusions: </strong>PDL enhancement for pediatric whole-body PET imaging may enable a reduction in acquisition time to 20 s per bed or a reduction in administered activity to approximately 22% of current clinical practice, while maintaining spatial resolution, contrast, quantitative accuracy, and diagnostic image quality.</p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2026-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13369067/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-026-00876-2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Deep learning (DL)-based denoising methods have shown promise for reducing radiation dose and/or acquisition time in pediatric PET imaging. However, conventional DL approaches typically require large and diverse training datasets to achieve generalizability. We propose a patch-based DL (PDL) approach that learns local structural representations from a single high-quality examination, with the goal of improving image quality and preserving quantitative accuracy of reduced-count pediatric whole-body PET while minimizing training burden.

Methods: This retrospective study included PET/CT datasets acquired on a GE Discovery MI Gen 2 scanner. A single pediatric examination with high structural conspicuity and low noise was used for training. Testing was performed using a NEMA phantom and 88 clinical pediatric examinations (age < 12 years) acquired with routine pediatric FDG dosing and a 90‑s‑per‑bed protocol. Clinical list‑mode data were truncated to 20 s per bed to simulate reduced‑count acquisitions; training and phantom datasets were downsampled to match this noise level. The PDL model was trained using paired full‑count and reduced‑count image patches and applied to denoise reduced‑count phantom and patient images. Phantom evaluations assessed spatial resolution, contrast recovery, and noise. Clinical evaluation included a blinded observer study and quantitative SUV analysis, followed by assessment of the noise-bias tradeoff.

Results: PDL preserved spatial resolution and contrast while achieving substantial noise reduction in phantom experiments. In the observer study, PDL‑enhanced 20‑s‑per‑bed images were rated as equivalent or superior in overall image quality and noise relative to standard 90‑s‑per‑bed images in more than 85% of cases. Small negative relative bias in SUVmax and SUVmean was observed in the liver, mediastinal blood pool, and lesions, with no statistically significant differences compared with standard‑count images. Compared with highly regularized reconstruction, PDL achieved greater noise reduction with reduced bias.

Conclusions: PDL enhancement for pediatric whole-body PET imaging may enable a reduction in acquisition time to 20 s per bed or a reduction in administered activity to approximately 22% of current clinical practice, while maintaining spatial resolution, contrast, quantitative accuracy, and diagnostic image quality.

使用基于贴片的深度学习减少儿科PET成像的获取时间/剂量。
背景:基于深度学习(DL)的去噪方法在儿童PET成像中显示出减少辐射剂量和/或采集时间的希望。然而,传统的深度学习方法通常需要大量不同的训练数据集来实现泛化。我们提出了一种基于补丁的深度学习(PDL)方法,该方法从单个高质量的检查中学习局部结构表示,目的是提高图像质量,保持减少计数的儿科全身PET的定量准确性,同时最大限度地减少训练负担。方法:本回顾性研究包括在GE Discovery MI Gen 2扫描仪上获得的PET/CT数据集。采用一种结构显著性高、噪声低的单一儿科检查方法进行训练。使用NEMA假体和88例临床儿科检查(年龄)进行测试。结果:PDL在假体实验中保持了空间分辨率和对比度,同时实现了显著的降噪。在观察者研究中,在85%以上的病例中,PDL增强的每张床20秒图像在整体图像质量和噪声方面与标准的每张床90秒图像相当或更好。在肝脏、纵隔血池和病变中观察到SUVmax和SUVmean的小负相对偏倚,与标准计数图像相比无统计学差异。与高度正则化重构相比,PDL在减小偏置的同时实现了更大的降噪效果。结论:在保持空间分辨率、对比度、定量准确性和诊断图像质量的同时,PDL增强儿童全身PET成像可以将采集时间减少到每张床20秒,或将给药活动减少到目前临床实践的约22%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
EJNMMI Physics
EJNMMI Physics Physics and Astronomy-Radiation
CiteScore
6.70
自引率
10.00%
发文量
78
审稿时长
13 weeks
期刊介绍: EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书