Association Between Micra Transcatheter Pacing System Curvature and Capture Threshold During Implantation.

IF 1.3
Pacing and clinical electrophysiology : PACE Pub Date : 2026-10-01 Epub Date: 2026-05-16 DOI:10.1111/pace.70279
Qiang Xing, Zukela Tuerhong, Renqing Guo, Jiasuoer Xiaokereti, Jianghua Zhang, Yaodong Li, Xianhui Zhou, Baopeng Tang
{"title":"Association Between Micra Transcatheter Pacing System Curvature and Capture Threshold During Implantation.","authors":"Qiang Xing, Zukela Tuerhong, Renqing Guo, Jiasuoer Xiaokereti, Jianghua Zhang, Yaodong Li, Xianhui Zhou, Baopeng Tang","doi":"10.1111/pace.70279","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>No previous studies have examined the relationship between Micra transcatheter pacing system (TPS) curvature and acceptable thresholds during implantation. This study aimed to evaluate the association between Micra TPS curvature and pre-deployment capture thresholds.</p><p><strong>Methods: </strong>The Micra TPS was successfully implanted with the assistance of right ventriculography in 180 patients. The curvature of the Micra TPS prior to deployment was analyzed using archived right anterior oblique (RAO) images from the first deployment, with the aid of Origin software (OriginLab Corporation, USA), while electrical parameters were recorded from 0 to 30 min at 10-min intervals.</p><p><strong>Results: </strong>Among 159 eligible patients, 126 (79.2%) demonstrated acceptable thresholds with a mean curvature of 0.58 ± 0.18. The high-threshold group (n = 33, 20.8%) exhibited significantly greater curvature (1.36 ± 0.64). Receiver operating characteristic analysis indicated that Micra TPS curvature ≤0.799 predicted acceptable thresholds with 90.9% sensitivity and 91.3% specificity (area under the curve = 0.958, 95% confidence interval: 0.924-0.992), with stable thresholds maintained in the acceptable group. No procedural complications occurred.</p><p><strong>Conclusions: </strong>A curvature of ≤0.799 in the RAO view of the Micra TPS prior to deployment reliably indicates acceptable capture thresholds. Combining curvature assessment with right ventriculography enhances the procedural safety of Micra implantation.</p>","PeriodicalId":520740,"journal":{"name":"Pacing and clinical electrophysiology : PACE","volume":" ","pages":"1588-1594"},"PeriodicalIF":1.3000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pacing and clinical electrophysiology : PACE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/pace.70279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/16 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: No previous studies have examined the relationship between Micra transcatheter pacing system (TPS) curvature and acceptable thresholds during implantation. This study aimed to evaluate the association between Micra TPS curvature and pre-deployment capture thresholds.

Methods: The Micra TPS was successfully implanted with the assistance of right ventriculography in 180 patients. The curvature of the Micra TPS prior to deployment was analyzed using archived right anterior oblique (RAO) images from the first deployment, with the aid of Origin software (OriginLab Corporation, USA), while electrical parameters were recorded from 0 to 30 min at 10-min intervals.

Results: Among 159 eligible patients, 126 (79.2%) demonstrated acceptable thresholds with a mean curvature of 0.58 ± 0.18. The high-threshold group (n = 33, 20.8%) exhibited significantly greater curvature (1.36 ± 0.64). Receiver operating characteristic analysis indicated that Micra TPS curvature ≤0.799 predicted acceptable thresholds with 90.9% sensitivity and 91.3% specificity (area under the curve = 0.958, 95% confidence interval: 0.924-0.992), with stable thresholds maintained in the acceptable group. No procedural complications occurred.

Conclusions: A curvature of ≤0.799 in the RAO view of the Micra TPS prior to deployment reliably indicates acceptable capture thresholds. Combining curvature assessment with right ventriculography enhances the procedural safety of Micra implantation.

植入期间Micra经导管起搏系统曲率与捕获阈值的关系。
背景:以前没有研究检查Micra经导管起搏系统(TPS)曲率与植入时可接受阈值的关系。本研究旨在评估Micra TPS曲率与预部署捕获阈值之间的关系。方法:在右心室造影辅助下成功植入Micra TPS 180例。在Origin软件(OriginLab Corporation, USA)的帮助下,使用首次部署时存档的右前斜(RAO)图像,分析部署前Micra TPS的曲率,同时以10分钟的间隔记录0至30分钟的电参数。结果:在159例符合条件的患者中,126例(79.2%)达到可接受的阈值,平均曲率为0.58±0.18。高阈值组(n = 33, 20.8%)表现出更大的曲率(1.36±0.64)。受试者工作特征分析表明,Micra TPS曲率≤0.799预测可接受阈值的灵敏度为90.9%,特异度为91.3%(曲线下面积= 0.958,95%置信区间为0.924 ~ 0.992),可接受组阈值保持稳定。无手术并发症发生。结论:部署前Micra TPS的RAO视图曲率≤0.799可靠地表明可接受的捕获阈值。曲率评估与右心室造影相结合,提高了Micra植入的手术安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书