Assessing the suitability of automated registration and segmentation for dosimetry calculations in SIRT treatment planning.

IF 3.5 2区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Félix Quinton, Romain Popoff, Fabrice Meriaudeau, Jean-Marc Vrigneaud, Olivier Chevallier, Julie Pellegrinelli, Jean-Louis Alberini, Benoit Presles
{"title":"Assessing the suitability of automated registration and segmentation for dosimetry calculations in SIRT treatment planning.","authors":"Félix Quinton, Romain Popoff, Fabrice Meriaudeau, Jean-Marc Vrigneaud, Olivier Chevallier, Julie Pellegrinelli, Jean-Louis Alberini, Benoit Presles","doi":"10.1186/s40658-026-00858-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Selective internal radiation therapy (SIRT) increasingly relies on accurate magnetic resonance imaging (MRI) to computed tomography (CT) registration and accurate liver and tumour segmentation, for effective pre-treatment planning. This study evaluates the impact of automatic registration and segmentation techniques on dosimetry calculations for SIRT treatment planning. It compares semi-automatic and automatic registration, as well as manual and automatic deep learning-based segmentation.</p><p><strong>Methods: </strong>Pre-treatment data from 90 patients with hepatocellular carcinoma were analysed. The dataset consisted of contrast-enhanced T1-weighted MRI scans with manually delineated liver and tumour volumes of interest (VOIs), as well as single-photon emission computed tomography (SPECT)/CT scans with manually or semi-automatically delineated liver VOI. The clinical routine pipeline, which involves semi-automatic registration and manual/semi-automatic segmentation, was used as the baseline pipeline and compared to experimental pipelines that use intensity-based deformable automatic registration or deep learning-based automatic segmentation. Dosimetric accuracy was assessed via metrics such as the mean absorbed dose, the minimum dose received by 70% of the volume (D70), and inverted cumulative dose-volume histograms.</p><p><strong>Results: </strong>Semi-automatic and automatic MRI to CT liver registration achieved comparable Dice scores of 92%. However, tumour registration varied significantly between registration methods yielding average Dice scores of 79%. Multimodal tumour segmentation approaches outperformed monomodal ones, achieving average Dice scores of 66.6 versus 62.5%. Using the baseline pipeline, the average tumour absorbed dose per patient was 115.6 Gy. Using the fully automatic approach, tumour absorbed doses differed from baseline values by an average of 6.6 Gy. Differences ranged from 0.3 Gy in the best case to 202.8 Gy when the automatic tumour segmentation markedly deviated from the manual delineation. Finally, it was found that a Dice score of at least 80% was required to avoid statistically significant differences in absorbed dose estimates between the clinical and automatic approaches.</p><p><strong>Conclusion: </strong>Semi-automatic and automatic registration show equivalent performance, allowing for complete automation. Automatic segmentation demonstrates promising results, with approximately 40% of patients achieving tumour Dice scores above the 80% threshold. 30% of cases show intermediate performance (60-80% tumour Dice scores), while the remaining 30% are still challenging. Further refinement of segmentation methods is required to enhance dosimetric accuracy.</p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2026-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13346394/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-026-00858-4","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Selective internal radiation therapy (SIRT) increasingly relies on accurate magnetic resonance imaging (MRI) to computed tomography (CT) registration and accurate liver and tumour segmentation, for effective pre-treatment planning. This study evaluates the impact of automatic registration and segmentation techniques on dosimetry calculations for SIRT treatment planning. It compares semi-automatic and automatic registration, as well as manual and automatic deep learning-based segmentation.

Methods: Pre-treatment data from 90 patients with hepatocellular carcinoma were analysed. The dataset consisted of contrast-enhanced T1-weighted MRI scans with manually delineated liver and tumour volumes of interest (VOIs), as well as single-photon emission computed tomography (SPECT)/CT scans with manually or semi-automatically delineated liver VOI. The clinical routine pipeline, which involves semi-automatic registration and manual/semi-automatic segmentation, was used as the baseline pipeline and compared to experimental pipelines that use intensity-based deformable automatic registration or deep learning-based automatic segmentation. Dosimetric accuracy was assessed via metrics such as the mean absorbed dose, the minimum dose received by 70% of the volume (D70), and inverted cumulative dose-volume histograms.

Results: Semi-automatic and automatic MRI to CT liver registration achieved comparable Dice scores of 92%. However, tumour registration varied significantly between registration methods yielding average Dice scores of 79%. Multimodal tumour segmentation approaches outperformed monomodal ones, achieving average Dice scores of 66.6 versus 62.5%. Using the baseline pipeline, the average tumour absorbed dose per patient was 115.6 Gy. Using the fully automatic approach, tumour absorbed doses differed from baseline values by an average of 6.6 Gy. Differences ranged from 0.3 Gy in the best case to 202.8 Gy when the automatic tumour segmentation markedly deviated from the manual delineation. Finally, it was found that a Dice score of at least 80% was required to avoid statistically significant differences in absorbed dose estimates between the clinical and automatic approaches.

Conclusion: Semi-automatic and automatic registration show equivalent performance, allowing for complete automation. Automatic segmentation demonstrates promising results, with approximately 40% of patients achieving tumour Dice scores above the 80% threshold. 30% of cases show intermediate performance (60-80% tumour Dice scores), while the remaining 30% are still challenging. Further refinement of segmentation methods is required to enhance dosimetric accuracy.

评估SIRT治疗计划中剂量学计算的自动注册和分割的适用性。
背景:选择性内放射治疗(SIRT)越来越依赖于精确的磁共振成像(MRI)到计算机断层扫描(CT)的配准以及准确的肝脏和肿瘤分割,以实现有效的治疗前计划。本研究评估了自动配准和分割技术对SIRT治疗计划剂量学计算的影响。它比较了半自动和自动配准,以及基于深度学习的手动和自动分割。方法:对90例肝癌患者的治疗前资料进行分析。该数据集包括对比度增强的t1加权MRI扫描,手动划定肝脏和肿瘤感兴趣体积(VOI),以及单光子发射计算机断层扫描(SPECT)/CT扫描,手动或半自动划定肝脏VOI。采用半自动配准和手动/半自动分割的临床常规管道作为基线管道,并与使用基于强度的可变形自动配准或基于深度学习的自动分割的实验管道进行比较。通过平均吸收剂量、接受70%体积的最小剂量(D70)和倒置累积剂量-体积直方图等指标来评估剂量学的准确性。结果:半自动和自动MRI到CT肝脏配准的Dice评分达到92%。然而,肿瘤登记在登记方法之间差异显著,平均骰子得分为79%。多模态肿瘤分割方法优于单模态方法,平均Dice得分为66.6比62.5%。使用基线管道,每位患者的平均肿瘤吸收剂量为115.6 Gy。使用全自动方法,肿瘤吸收剂量与基线值平均相差6.6 Gy。当自动肿瘤分割明显偏离人工划定时,差异范围从最佳情况下的0.3 Gy到202.8 Gy。最后,我们发现需要至少80%的Dice分数才能避免临床和自动方法之间吸收剂量估计的统计显着差异。结论:半自动配准与自动配准性能相当,可实现完全自动化。自动分割显示出有希望的结果,大约40%的患者达到肿瘤Dice评分超过80%的阈值。30%的病例表现中等(60-80%的肿瘤骰子得分),而剩下的30%仍然具有挑战性。需要进一步改进分割方法以提高剂量测定的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
EJNMMI Physics
EJNMMI Physics Physics and Astronomy-Radiation
CiteScore
6.70
自引率
10.00%
发文量
78
审稿时长
13 weeks
期刊介绍: EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书