Characteristics of trainee interpretation time during simulated screening mammography.

L R Salkowski, L R Murphy, E M Yüksel, N A Fellinger, E A Krupinski, A M Fowler, H A Vlach, C S Green, M A Elezaby
{"title":"Characteristics of trainee interpretation time during simulated screening mammography.","authors":"L R Salkowski, L R Murphy, E M Yüksel, N A Fellinger, E A Krupinski, A M Fowler, H A Vlach, C S Green, M A Elezaby","doi":"10.1117/12.3085064","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Efficiency in screening mammogram interpretation is complex and involves the time to view the images and report the findings. The purpose of this study was to evaluate the factors impacting the interpretation time of screening mammograms by radiology residents.</p><p><strong>Materials and methods: </strong>In this IRB-approved prospective study, radiology residents performed screening mammography simulations during their breast imaging rotations. The research simulation space replicated the clinical practice area without the interruptions. Residents interpreted 50 enriched screening mammograms and completed eye tracking on the first ten cases (six digital breast tomosynthesis (DBT) and four full-field digital mammogram (FFDM) cases). The amount of time to interpret (visual inspection) and report the 10 eye-tracking cases (electronic reporting) was evaluated and compared based on the breast imaging rotation (first, second, or third) and postgraduate year level (PGY). We present the time for each of the 10 eye tracking cases that were subdivided into visual inspection time of the mammogram and reporting time. Comparisons were performed with t-test and significance at p≤0.05.</p><p><strong>Results: </strong>25 residents performed the simulation with eye tracking: 14 residents during their first rotation, 7 in their second, and 4 in their third. There were 5 PGY2, 8 PGY3, 7 PGY4 and 5 PGY5 residents.The average overall interpretation time for 50 cases was 4.12 hours (SD=1.26), and 1.35 hours for the 10 eye tracking cases. For the eye-tracking cases, the average visual inspection time per case was 2.13 minutes with a reporting time of 3.08 minutes for an overall interpretation time of 5.21 minutes per case.For eye-tracking cases, the overall interpretation time significantly decreased from those completing their first (6.0 min) to third (4.2 min) breast rotation (p<0.001) and from PGY2 (6.6 min) to PGY5 (4.8 min) (p=0.004). The visual inspection time significantly decreased from PGY2 (2.6 min) compared to PGY5 (1.8 min) (p=0.001) level and from the first to the third rotation (p=0.021).No significant differences were observed for overall interpretation time between DBT (5.29 min) and FFDM (5.69 min) (p=0.319) or visual inspection time per case for DBT (2.20 min) and FFDM (2.03 min) (p=0.335).</p><p><strong>Conclusion: </strong>Interpretation time for screening mammography decreases with increasing PGY level and the number of breast imaging rotations, which is likely due to experience and confidence with the types of exams. No difference was noted between DBT and FFDM average times.</p>","PeriodicalId":74505,"journal":{"name":"Proceedings of SPIE--the International Society for Optical Engineering","volume":"13928 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13160490/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of SPIE--the International Society for Optical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.3085064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/2 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Efficiency in screening mammogram interpretation is complex and involves the time to view the images and report the findings. The purpose of this study was to evaluate the factors impacting the interpretation time of screening mammograms by radiology residents.

Materials and methods: In this IRB-approved prospective study, radiology residents performed screening mammography simulations during their breast imaging rotations. The research simulation space replicated the clinical practice area without the interruptions. Residents interpreted 50 enriched screening mammograms and completed eye tracking on the first ten cases (six digital breast tomosynthesis (DBT) and four full-field digital mammogram (FFDM) cases). The amount of time to interpret (visual inspection) and report the 10 eye-tracking cases (electronic reporting) was evaluated and compared based on the breast imaging rotation (first, second, or third) and postgraduate year level (PGY). We present the time for each of the 10 eye tracking cases that were subdivided into visual inspection time of the mammogram and reporting time. Comparisons were performed with t-test and significance at p≤0.05.

Results: 25 residents performed the simulation with eye tracking: 14 residents during their first rotation, 7 in their second, and 4 in their third. There were 5 PGY2, 8 PGY3, 7 PGY4 and 5 PGY5 residents.The average overall interpretation time for 50 cases was 4.12 hours (SD=1.26), and 1.35 hours for the 10 eye tracking cases. For the eye-tracking cases, the average visual inspection time per case was 2.13 minutes with a reporting time of 3.08 minutes for an overall interpretation time of 5.21 minutes per case.For eye-tracking cases, the overall interpretation time significantly decreased from those completing their first (6.0 min) to third (4.2 min) breast rotation (p<0.001) and from PGY2 (6.6 min) to PGY5 (4.8 min) (p=0.004). The visual inspection time significantly decreased from PGY2 (2.6 min) compared to PGY5 (1.8 min) (p=0.001) level and from the first to the third rotation (p=0.021).No significant differences were observed for overall interpretation time between DBT (5.29 min) and FFDM (5.69 min) (p=0.319) or visual inspection time per case for DBT (2.20 min) and FFDM (2.03 min) (p=0.335).

Conclusion: Interpretation time for screening mammography decreases with increasing PGY level and the number of breast imaging rotations, which is likely due to experience and confidence with the types of exams. No difference was noted between DBT and FFDM average times.

模拟筛查乳房x线摄影中受训者解释时间的特点。
目的:乳房x线检查的效率是复杂的,涉及到查看图像和报告结果的时间。本研究的目的是评估影响放射科住院医师对乳房x光筛检解释时间的因素。材料和方法:在这项经irb批准的前瞻性研究中,放射科住院医师在乳房成像轮换期间进行筛查性乳房x线摄影模拟。研究模拟空间复制了临床实践区域,没有中断。住院医师解读了50张富集筛查乳房x光片,并对前10例(6例数字乳腺断层合成(DBT)和4例全视野数字乳房x光片(FFDM))完成了眼动追踪。对10例眼动追踪病例的解释(目视检查)和报告(电子报告)的时间进行评估,并根据乳房成像轮换(第一、第二或第三次)和研究生年级水平(PGY)进行比较。我们提出了每10眼动追踪病例的时间,细分为乳房x光片的视觉检查时间和报告时间。比较采用t检验,p≤0.05为显著性。结果:25名住院医生进行了眼动追踪模拟:14名住院医生在第一次轮转,7名在第二次轮转,4名在第三次轮转。PGY2 5名,PGY3 8名,PGY4 7名,PGY5 5名。50例的平均整体解读时间为4.12小时(SD=1.26), 10例眼动追踪的平均整体解读时间为1.35小时。眼动追踪病例平均每例目视检查时间为2.13分钟,报告时间为3.08分钟,整体解释时间为5.21分钟。对于眼球追踪病例,从完成第一次乳房旋转(6.0 min)到完成第三次乳房旋转(4.2 min),总体解释时间显著缩短(p结论:随着PGY水平的增加和乳房成像旋转次数的增加,乳房筛查的解释时间减少,这可能是由于经验和对检查类型的信心所致。DBT和FFDM的平均时间没有差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书