THERMOGRAPHY ACCURACY IN THE DIAGNOSIS OF CARPAL TUNNEL SYNDROME.

IF 0.6 4区 医学 Q4 ORTHOPEDICS
Acta Ortopedica Brasileira Pub Date : 2026-05-11 eCollection Date: 2026-01-01 DOI:10.1590/1413-785220263402e283215
Maria Fernanda Franco de Oliveira Dos Anjos, Sérgio Murilo Georgeto, Maycon Anderson Guedes Maciel Moreira, Rodrigo Antônio Carvalho Andraus
{"title":"THERMOGRAPHY ACCURACY IN THE DIAGNOSIS OF CARPAL TUNNEL SYNDROME.","authors":"Maria Fernanda Franco de Oliveira Dos Anjos, Sérgio Murilo Georgeto, Maycon Anderson Guedes Maciel Moreira, Rodrigo Antônio Carvalho Andraus","doi":"10.1590/1413-785220263402e283215","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the accuracy of thermography for diagnosing carpal tunnel syndrome (CTS) compared to electroneuromyography (ENMG), considered the gold standard, in patients with an indication for surgical treatment recruited from the neurosurgery outpatient clinic of the Irmandade da Santa Casa de Londrina.</p><p><strong>Methods: </strong>This is a cross-sectional, descriptive diagnostic accuracy study, oriented by the Guideline for Reporting Reliability and Agreement Studies (GRAAS), with a sample from the database of the project \"Clinical-functional characterization and evaluation of the treatment efficacy of patients with carpal tunnel syndrome\" of 44 patients, both genders, divided into a study group with 17 participants and a control group with 27 participants. A FLIR® T540 camera was used to capture the thermographic images. The data was acquired and analyzed using FLIR Tools+ software, which measured the average temperature of the region of interest. Artificial Neural Networks were used to classify the thermographic images.</p><p><strong>Results: </strong>In terms of the area under the curve was 0.908, the precision obtained was 90.81%, the accuracy 91.66%, the sensitivity 87.25% and the specificity 94.44%. The F1-score was 88.99%.</p><p><strong>Conclusion: </strong>The main findings, such as the sensitivity and specificity values, showed significant results indicating that thermography is effective in detecting CTS. <b>Level of Evidence I; Diagnostic studies - Investigating a Diagnostic Test</b>.</p>","PeriodicalId":55563,"journal":{"name":"Acta Ortopedica Brasileira","volume":"34 2","pages":"e283215"},"PeriodicalIF":0.6000,"publicationDate":"2026-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13167038/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Ortopedica Brasileira","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1413-785220263402e283215","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the accuracy of thermography for diagnosing carpal tunnel syndrome (CTS) compared to electroneuromyography (ENMG), considered the gold standard, in patients with an indication for surgical treatment recruited from the neurosurgery outpatient clinic of the Irmandade da Santa Casa de Londrina.

Methods: This is a cross-sectional, descriptive diagnostic accuracy study, oriented by the Guideline for Reporting Reliability and Agreement Studies (GRAAS), with a sample from the database of the project "Clinical-functional characterization and evaluation of the treatment efficacy of patients with carpal tunnel syndrome" of 44 patients, both genders, divided into a study group with 17 participants and a control group with 27 participants. A FLIR® T540 camera was used to capture the thermographic images. The data was acquired and analyzed using FLIR Tools+ software, which measured the average temperature of the region of interest. Artificial Neural Networks were used to classify the thermographic images.

Results: In terms of the area under the curve was 0.908, the precision obtained was 90.81%, the accuracy 91.66%, the sensitivity 87.25% and the specificity 94.44%. The F1-score was 88.99%.

Conclusion: The main findings, such as the sensitivity and specificity values, showed significant results indicating that thermography is effective in detecting CTS. Level of Evidence I; Diagnostic studies - Investigating a Diagnostic Test.

热成像在腕管综合征诊断中的准确性。
目的:评价热成像诊断腕管综合征(CTS)的准确性,与被认为是金标准的神经肌电图(ENMG)相比,对来自伦敦圣之家医院(Irmandade da Santa Casa de Londrina)神经外科门诊有手术指征的患者进行热成像诊断。方法:本研究是一项横断面、描述性诊断准确性研究,以报告可靠性和一致性研究指南(GRAAS)为导向,样本来自“腕管综合征患者临床功能特征和治疗疗效评价”项目数据库的44例患者,男女均可,分为研究组17例和对照组27例。使用FLIR®T540相机捕获热成像图像。使用FLIR Tools+软件获取和分析数据,该软件测量了感兴趣区域的平均温度。采用人工神经网络对热成像图像进行分类。结果:曲线下面积为0.908,精密度为90.81%,准确度为91.66%,灵敏度为87.25%,特异度为94.44%。f1评分为88.99%。结论:热像仪在CTS检测中的灵敏度和特异度均有显著的结果,表明热像仪对CTS的检测是有效的。证据等级I;诊断研究-调查诊断测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.90
自引率
14.30%
发文量
67
审稿时长
25 weeks
期刊介绍: A Revista Acta Ortopédica Brasileira, órgão oficial do Departamento de Ortopedia e Traumatologia da Faculdade de Medicina da Universidade de São Paulo (DOT/FMUSP), é publicada bimestralmente em seis edições ao ano (jan/fev, mar/abr, maio/jun, jul/ago, set/out e nov/dez) com versão em inglês disponível nos principais indexadores nacionais e internacionais e instituições de ensino do Brasil. Sendo hoje reconhecidamente uma importante contribuição para os especialistas da área com sua seriedade e árduo trabalho para as indexações já conquistadas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书