A novel method of determining a body surface for collision detection using CT localization radiograph.

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Yusuke Ochi, Akito S Koganezawa, Takeo Nakashima, Yuji Murakami
{"title":"A novel method of determining a body surface for collision detection using CT localization radiograph.","authors":"Yusuke Ochi, Akito S Koganezawa, Takeo Nakashima, Yuji Murakami","doi":"10.1007/s13246-026-01736-0","DOIUrl":null,"url":null,"abstract":"<p><p>In previous studies, identifying a position at high collision risk outside a range of CT imaging requires a cost, such as an infrared camera. In this study, we propose a simple method to identify the patient's body surface using localization radiographs in a planning CT that are available at any facility. Five metallic markers were attached to the mannequin's right elbow with the arm up. Twelve localization radiographs were acquired at 30° intervals from 0° to 330° of the tube angle. The images acquired at 60°, 90°, 120°, 150°, 180°, 270°, 300°, and 330° of the tube angle were used to estimate the metallic markers' position. The three-dimensional (3D) estimated coordinate (EC) of the metallic markers (X, Y, Z) was calculated from the two selected localization radiographs and compared to the reference coordinate (RC). The average of the difference between the EC and the RC was [Formula: see text] -  1.4 ± 3.5 mm, [Formula: see text] = - 3.1 ± 6.2 mm and [Formula: see text] = 0.8 ± 0.5 mm. When the set of combined tube angles (α, β) was (60°,270°), (120°,300°), and (180°,330°), the average distance between RC and EC exceeded 10.0 mm. The maximum distance between RC and EC was 46.7 mm. The distance between the mannequin's elbow and the gantry surface estimated by the TPS differed by 0.2 cm compared with the direct measurement in the treatment room. This study proposed a novel method for estimating patient body surface coordinates using localization radiographs, with sufficient accuracy to prevent collisions between the patient's body surface and the gantry.</p>","PeriodicalId":48490,"journal":{"name":"Physical and Engineering Sciences in Medicine","volume":" ","pages":"1241-1250"},"PeriodicalIF":2.4000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical and Engineering Sciences in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-026-01736-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In previous studies, identifying a position at high collision risk outside a range of CT imaging requires a cost, such as an infrared camera. In this study, we propose a simple method to identify the patient's body surface using localization radiographs in a planning CT that are available at any facility. Five metallic markers were attached to the mannequin's right elbow with the arm up. Twelve localization radiographs were acquired at 30° intervals from 0° to 330° of the tube angle. The images acquired at 60°, 90°, 120°, 150°, 180°, 270°, 300°, and 330° of the tube angle were used to estimate the metallic markers' position. The three-dimensional (3D) estimated coordinate (EC) of the metallic markers (X, Y, Z) was calculated from the two selected localization radiographs and compared to the reference coordinate (RC). The average of the difference between the EC and the RC was [Formula: see text] -  1.4 ± 3.5 mm, [Formula: see text] = - 3.1 ± 6.2 mm and [Formula: see text] = 0.8 ± 0.5 mm. When the set of combined tube angles (α, β) was (60°,270°), (120°,300°), and (180°,330°), the average distance between RC and EC exceeded 10.0 mm. The maximum distance between RC and EC was 46.7 mm. The distance between the mannequin's elbow and the gantry surface estimated by the TPS differed by 0.2 cm compared with the direct measurement in the treatment room. This study proposed a novel method for estimating patient body surface coordinates using localization radiographs, with sufficient accuracy to prevent collisions between the patient's body surface and the gantry.

一种基于CT定位x线图像的碰撞检测体表确定新方法。
在之前的研究中,在CT成像范围之外识别高碰撞风险的位置需要一定的成本,例如红外摄像机。在这项研究中,我们提出了一种简单的方法来识别病人的体表使用定位x线片在规划CT,可在任何设施。五个金属标记贴在模特的右肘上,手臂向上。在0°至330°的管角间隔30°拍摄12张定位x线片。在管子角度的60°、90°、120°、150°、180°、270°、300°和330°处获得的图像用于估计金属标记物的位置。从选定的两张定位X, Y, Z金属标记物的三维(3D)估计坐标(EC)计算,并与参考坐标(RC)进行比较。EC和RC之间的平均差异为[公式:见文]- 1.4±3.5 mm,[公式:见文]= - 3.1±6.2 mm和[公式:见文]= 0.8±0.5 mm。当组合管角(α, β)分别为(60°,270°),(120°,300°)和(180°,330°)时,RC与EC之间的平均距离超过10.0 mm。RC与EC之间的最大距离为46.7 mm。与在治疗室直接测量相比,TPS估计的人体模型肘部与龙门架表面之间的距离相差0.2 cm。本研究提出了一种利用定位x线片估计患者体表坐标的新方法,具有足够的精度以防止患者体表与龙门之间的碰撞。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.40
自引率
4.50%
发文量
110
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书