An osteoporotic bone model: developing and validating an ex-vivo bone demineralization protocol.

IF 3 Q2 ENDOCRINOLOGY & METABOLISM
JBMR Plus Pub Date : 2026-04-15 eCollection Date: 2026-06-01 DOI:10.1093/jbmrpl/ziag069
Fahad Alabdah, Adel Alshammari, Araida Hidalgo-Bastida, Glen Cooper
{"title":"An osteoporotic bone model: developing and validating an ex-vivo bone demineralization protocol.","authors":"Fahad Alabdah, Adel Alshammari, Araida Hidalgo-Bastida, Glen Cooper","doi":"10.1093/jbmrpl/ziag069","DOIUrl":null,"url":null,"abstract":"<p><p>Studies estimate that there are 500 million osteoporotic patients worldwide. Osteoporosis leads to 2.7 million hip fractures annually. These fractures usually require synthetic implants known as total hip replacement. Orthopedic implant development is an ongoing process, which requires numerous tests to evaluate their feasibility, in addition to the International Standards Organization regulatory tests. These tests require human cadaveric bones and animal in vivo experiments, which are associated with high costs, are time-consuming and limited through regulations, which poses a challenge. Following the replacement, reduction and refinement principle in animal testing (3Rs), this study aims to develop and evaluate a protocol where osteoporotic samples are prepared through ex vivo procedure using sheep bones from the food chain, given their availability and size, which is considerably similar to human cadaveric bones. Sheep femurs were demineralized using hydrochloric acid at different time intervals, resulting in changes in the bone architecture, mineral density, and mechanical properties. Demineralized specimens exhibited progressive reductions in mechanical performance and trabecular integrity with increasing demineralization time. Young's modulus decreased from 110.7 ± 28.8 MPa in Control group to 88.7 ± 16.0 MPa and 57.7 ± 6.0 MPa in the 48H and 96H groups, respectively, accompanied by corresponding reductions in failure load. Trabecular microstructure was significantly altered, with trabecular thickness decreasing and trabecular separation and porosity increasing, reaching an approximately 30% higher porosity in the 96H group compared with Control group. Volumetric BMD (vBMD) was significantly reduced by both demineralization treatments (33% relative decrease). Despite the limited sample size, consistent trends indicate meaningful changes with demineralization. The observed structural and mechanical properties fall within reported ranges for human osteoporotic trabecular bone, supporting the use of demineralized sheep bone as a cost-effective ex vivo model for osteoporotic studies and preliminary orthopedic device evaluation.</p>","PeriodicalId":14611,"journal":{"name":"JBMR Plus","volume":"10 6","pages":"ziag069"},"PeriodicalIF":3.0000,"publicationDate":"2026-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13160424/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JBMR Plus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jbmrpl/ziag069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Studies estimate that there are 500 million osteoporotic patients worldwide. Osteoporosis leads to 2.7 million hip fractures annually. These fractures usually require synthetic implants known as total hip replacement. Orthopedic implant development is an ongoing process, which requires numerous tests to evaluate their feasibility, in addition to the International Standards Organization regulatory tests. These tests require human cadaveric bones and animal in vivo experiments, which are associated with high costs, are time-consuming and limited through regulations, which poses a challenge. Following the replacement, reduction and refinement principle in animal testing (3Rs), this study aims to develop and evaluate a protocol where osteoporotic samples are prepared through ex vivo procedure using sheep bones from the food chain, given their availability and size, which is considerably similar to human cadaveric bones. Sheep femurs were demineralized using hydrochloric acid at different time intervals, resulting in changes in the bone architecture, mineral density, and mechanical properties. Demineralized specimens exhibited progressive reductions in mechanical performance and trabecular integrity with increasing demineralization time. Young's modulus decreased from 110.7 ± 28.8 MPa in Control group to 88.7 ± 16.0 MPa and 57.7 ± 6.0 MPa in the 48H and 96H groups, respectively, accompanied by corresponding reductions in failure load. Trabecular microstructure was significantly altered, with trabecular thickness decreasing and trabecular separation and porosity increasing, reaching an approximately 30% higher porosity in the 96H group compared with Control group. Volumetric BMD (vBMD) was significantly reduced by both demineralization treatments (33% relative decrease). Despite the limited sample size, consistent trends indicate meaningful changes with demineralization. The observed structural and mechanical properties fall within reported ranges for human osteoporotic trabecular bone, supporting the use of demineralized sheep bone as a cost-effective ex vivo model for osteoporotic studies and preliminary orthopedic device evaluation.

骨质疏松性骨模型:开发和验证离体骨脱矿方案。
研究估计,全世界有5亿骨质疏松症患者。骨质疏松症每年导致270万例髋部骨折。这些骨折通常需要人工植入物,即全髋关节置换术。骨科植入物的开发是一个持续的过程,除了国际标准组织的监管测试外,还需要进行大量的测试来评估其可行性。这些测试需要人体尸骨和动物体内实验,成本高,耗时长,且受法规限制,这是一个挑战。遵循动物试验中的替代、还原和细化原则(3Rs),本研究旨在开发和评估一种方案,利用食物链中的羊骨通过离体程序制备骨质疏松样品,因为它们的可用性和大小与人类尸体骨骼相当相似。在不同的时间间隔使用盐酸对绵羊股骨进行脱矿,导致骨结构、矿物质密度和力学性能的变化。随着脱矿时间的延长,脱矿标本的力学性能和小梁完整性逐渐降低。杨氏模量从对照组的110.7±28.8 MPa下降到48H和96H组的88.7±16.0 MPa和57.7±6.0 MPa,同时失效载荷也相应降低。小梁微观结构发生明显改变,小梁厚度减小,小梁分离度和孔隙度增加,96H组的孔隙度比对照组高约30%。两种脱矿处理均显著降低了体积骨密度(vBMD)(相对降低33%)。尽管样本量有限,但一致的趋势表明脱矿有意义的变化。观察到的结构和力学性能符合报道的人类骨质疏松小梁骨的范围,支持将脱矿羊骨作为骨质疏松研究和初步矫形装置评估的经济有效的离体模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JBMR Plus
JBMR Plus Medicine-Orthopedics and Sports Medicine
CiteScore
5.80
自引率
2.60%
发文量
103
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书