{"title":"Highly selective detection of trace methyl sec-butyl ether using cataluminescence sensor based on mesoporous CeO<sub>2</sub> nanoparticles","authors":"Chengcheng Wan, Zhaoru Ban, Dan Zhang, Junbao He, Yanju Chen, Shan Tang, Qianchun Zhang","doi":"10.1088/1361-6501/adf24a","DOIUrl":null,"url":null,"abstract":"Abstract Methyl sec-butyl ether (MSBE), a volatile organic compound, poses significant risks to both environmental safety and human health. Consequently, developing efficient sensors for the rapid and accurate detection of trace levels of MSBE is essential. In this study, we synthesized mesoporous CeO 2 nanoparticles using carbon quantum dots as templates, resulting in the development of a highly sensitive cataluminescence sensor system. This sensor demonstrated an impressive linear detection range of 0.50–20 mg l −1 ( R 2 = 0.998) and a low detection limit of 0.08 mg l −1 , coupled with a signal-to-noise ratio (S/N) of 3. We applied the mesoporous CeO 2 nanoparticle sensor to measure MSBE levels in various environments, including a volatile medicine reagent freezer, laboratory gas, and a storage cabinet, which yielded concentrations of 2.07, 1.38, and 3.96 mg l −1 , respectively. The sensor also exhibited excellent recovery rates, ranging from 91.1% to 110%, with relative standard deviations ( RSD, n = 5) from 3.4% to 8.7%, indicating reliable performance. Additionally, gas chromatography-mass spectrometry was employed to elucidate the mechanism underlying the developed cataluminescence sensor. This study introduces a versatile approach for designing gas sensors for MSBE that not only exhibits high sensitivity and selectivity but also significantly enhances their potential applications in both industrial and environmental monitoring.","PeriodicalId":18526,"journal":{"name":"Measurement Science and Technology","volume":"36 8","pages":"085104-085104"},"PeriodicalIF":3.7000,"publicationDate":"2025-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Science and Technology","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.1088/1361-6501/adf24a","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 2
Abstract
Abstract Methyl sec-butyl ether (MSBE), a volatile organic compound, poses significant risks to both environmental safety and human health. Consequently, developing efficient sensors for the rapid and accurate detection of trace levels of MSBE is essential. In this study, we synthesized mesoporous CeO 2 nanoparticles using carbon quantum dots as templates, resulting in the development of a highly sensitive cataluminescence sensor system. This sensor demonstrated an impressive linear detection range of 0.50–20 mg l −1 ( R 2 = 0.998) and a low detection limit of 0.08 mg l −1 , coupled with a signal-to-noise ratio (S/N) of 3. We applied the mesoporous CeO 2 nanoparticle sensor to measure MSBE levels in various environments, including a volatile medicine reagent freezer, laboratory gas, and a storage cabinet, which yielded concentrations of 2.07, 1.38, and 3.96 mg l −1 , respectively. The sensor also exhibited excellent recovery rates, ranging from 91.1% to 110%, with relative standard deviations ( RSD, n = 5) from 3.4% to 8.7%, indicating reliable performance. Additionally, gas chromatography-mass spectrometry was employed to elucidate the mechanism underlying the developed cataluminescence sensor. This study introduces a versatile approach for designing gas sensors for MSBE that not only exhibits high sensitivity and selectivity but also significantly enhances their potential applications in both industrial and environmental monitoring.
期刊介绍:
Measurement Science and Technology publishes articles on new measurement techniques and associated instrumentation. Papers that describe experiments must represent an advance in measurement science or measurement technique rather than the application of established experimental technique. Bearing in mind the multidisciplinary nature of the journal, authors must provide an introduction to their work that makes clear the novelty, significance, broader relevance of their work in a measurement context and relevance to the readership of Measurement Science and Technology. All submitted articles should contain consideration of the uncertainty, precision and/or accuracy of the measurements presented.
Subject coverage includes the theory, practice and application of measurement in physics, chemistry, engineering and the environmental and life sciences from inception to commercial exploitation. Publications in the journal should emphasize the novelty of reported methods, characterize them and demonstrate their performance using examples or applications.