{"title":"Finite Element Analysis on the Effect of Activation Time on Cervical Spine Biomechanical Response During Pilot Ejection.","authors":"Jiongxiang Zhao, Zanni Zhang, Zsolt Radak, Xuanzhen Cen, Ee-Chon Teo, Minjun Liang, Yaodong Gu","doi":"10.1155/abb/7484728","DOIUrl":null,"url":null,"abstract":"<p><p>This study uses finite element analysis (FEA) to investigate different muscle activation times on the cervical spine biomechanical responses in pilot ejection. A validated C0-T1 cervical spine model, incorporating vertebrae, intervertebral discs, ligaments, and 13 major active muscles, was subjected to simulated ejection conditions of 10G vertical acceleration over 150 ms. Activation times ranging from 26 to 92 ms were analyzed to evaluate their impact on vertebral rotation, disc stress, and injury risk. Results demonstrated that shorter activation times (26-46 ms) reduced excessive flexion at C3-C4 and C4-C5; these earlier muscle engagements enhance spinal stability. Conversely, longer delays (76-92 ms) increased rotational angles at C5-C7, exacerbating hyperflexion-related injury risks. An optimal activation time of approximately 46 ms minimized flexion without inducing compensatory hyperextension, balancing load distribution across cervical segments. These findings emphasize the critical role of neuromuscular response timing in mitigating cervical spine injuries during high-G ejection. The study provides insights for optimizing pilot safety through tailored muscle activation strategies, sophisticated artificial intelligence (AI) protective equipment design, and training protocols.</p>","PeriodicalId":8029,"journal":{"name":"Applied Bionics and Biomechanics","volume":"2026 ","pages":"7484728"},"PeriodicalIF":1.7000,"publicationDate":"2026-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13131905/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Bionics and Biomechanics","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1155/abb/7484728","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study uses finite element analysis (FEA) to investigate different muscle activation times on the cervical spine biomechanical responses in pilot ejection. A validated C0-T1 cervical spine model, incorporating vertebrae, intervertebral discs, ligaments, and 13 major active muscles, was subjected to simulated ejection conditions of 10G vertical acceleration over 150 ms. Activation times ranging from 26 to 92 ms were analyzed to evaluate their impact on vertebral rotation, disc stress, and injury risk. Results demonstrated that shorter activation times (26-46 ms) reduced excessive flexion at C3-C4 and C4-C5; these earlier muscle engagements enhance spinal stability. Conversely, longer delays (76-92 ms) increased rotational angles at C5-C7, exacerbating hyperflexion-related injury risks. An optimal activation time of approximately 46 ms minimized flexion without inducing compensatory hyperextension, balancing load distribution across cervical segments. These findings emphasize the critical role of neuromuscular response timing in mitigating cervical spine injuries during high-G ejection. The study provides insights for optimizing pilot safety through tailored muscle activation strategies, sophisticated artificial intelligence (AI) protective equipment design, and training protocols.

飞行员弹射过程中激活时间对颈椎生物力学反应影响的有限元分析。
本研究采用有限元分析(FEA)研究不同肌肉激活时间对飞行员弹射时颈椎生物力学反应的影响。建立一个包含椎骨、椎间盘、韧带和13块主要活动肌肉的经验证的C0-T1颈椎模型,模拟垂直加速度10G超过150 ms的弹射条件。激活时间范围为26 ~ 92 ms,以评估其对椎体旋转、椎间盘应力和损伤风险的影响。结果表明,较短的激活时间(26-46 ms)减少了C3-C4和C4-C5的过度屈曲;这些早期的肌肉活动增强了脊柱的稳定性。相反,较长的延迟(76-92 ms)增加了C5-C7的旋转角度,加剧了过度屈曲相关的损伤风险。最佳激活时间约为46毫秒,最大限度地减少屈曲,而不会引起代偿性过伸,平衡颈椎节段的负荷分布。这些发现强调了神经肌肉反应时间在减轻高g射血时颈椎损伤中的关键作用。该研究通过量身定制的肌肉激活策略、复杂的人工智能(AI)防护装备设计和训练方案,为优化飞行员的安全提供了见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Bionics and Biomechanics
Applied Bionics and Biomechanics ENGINEERING, BIOMEDICAL-ROBOTICS
自引率
4.50%
发文量
338
审稿时长
>12 weeks
期刊介绍: Applied Bionics and Biomechanics publishes papers that seek to understand the mechanics of biological systems, or that use the functions of living organisms as inspiration for the design new devices. Such systems may be used as artificial replacements, or aids, for their original biological purpose, or be used in a different setting altogether.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书