Artificial intelligence-based retinal vascular fractal dimension quantification and related factors: A retrospective study

IF 7.8 Q1 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Intelligent medicine Pub Date : 2026-04-01 Epub Date: 2025-12-12 DOI:10.1016/j.imed.2025.12.002
Chuan Zhang , Haotian Wu , Saiguang Ling , Zhou Dong , Li Dong , Ruiheng Zhang , Wenbin Wei , Lei Shao
{"title":"Artificial intelligence-based retinal vascular fractal dimension quantification and related factors: A retrospective study","authors":"Chuan Zhang ,&nbsp;Haotian Wu ,&nbsp;Saiguang Ling ,&nbsp;Zhou Dong ,&nbsp;Li Dong ,&nbsp;Ruiheng Zhang ,&nbsp;Wenbin Wei ,&nbsp;Lei Shao","doi":"10.1016/j.imed.2025.12.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Fractal dimension (D<sub>f</sub>) quantifies vascular network complexity and spatial filling density, providing a non-invasive biomarker for microvascular pathology assessment. We aimed to establish an artificial intelligence (AI)–powered framework for automated D<sub>f</sub> quantification and investigate its clinical implications in a general population of the Beijing Eye Study.</div></div><div><h3>Methods</h3><div>This retrospective study utilized data from the Beijing Eye Study 2011. Fundus images meeting quality criteria were processed with an AI algorithm to segment retinal vasculature and calculate D<sub>f</sub>. Multiple linear and logistic regression models were used to assess the associations of retinal vascular D<sub>f</sub> with systemic and ocular parameters.</div></div><div><h3>Results</h3><div>AI-based quantification of retinal vascular D<sub>f</sub> was successfully performed in 3,298 participants (95.1% of 3,468 participants), demonstrating high model performance: segmentation accuracy (0.9660), sensitivity (0.8879), specificity (0.9743), and intersection-over-union (IoU) (0.7110). The mean D<sub>f</sub> was 1.51 ± 0.09 (median: 1.53; interquartile range: 1.50–1.55). In multiple linear regression analysis, reduced D<sub>f</sub> was significantly associated with older age (standardized regression coefficient (sβ) = −2.346; <em>P</em> &lt; 0.001), higher systolic blood pressure (sβ = −0.341; <em>P</em> &lt; 0.001), smaller hip circumference (sβ = 0.518; <em>P</em> = 0.014), lower equivalent diopter (sβ = 3.589; <em>P</em> &lt; 0.001), thinner retinal nerve fiber layer thickness (sβ = 0.390; <em>P</em> = 0.002), smaller arteriovenous ratio (sβ = 524.590; <em>P</em> &lt; 0.001), and thinner subfoveal choroidal thickness (sβ = 0.071; <em>P</em> &lt; 0.001). In the logistic regression model, the risk prevalence of hypertension increased with the decrease in D<sub>f</sub> (OR = 0.853, 95% CI: 0.651–0.801).</div></div><div><h3>Conclusion</h3><div>AI-powered D<sub>f</sub> analysis may be used as a novel quantitative platform for characterizing retinal microvascular morphological alterations.</div></div>","PeriodicalId":73400,"journal":{"name":"Intelligent medicine","volume":"6 2","pages":"Pages 146-153"},"PeriodicalIF":7.8000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Intelligent medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667102625001342","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Fractal dimension (Df) quantifies vascular network complexity and spatial filling density, providing a non-invasive biomarker for microvascular pathology assessment. We aimed to establish an artificial intelligence (AI)–powered framework for automated Df quantification and investigate its clinical implications in a general population of the Beijing Eye Study.

Methods

This retrospective study utilized data from the Beijing Eye Study 2011. Fundus images meeting quality criteria were processed with an AI algorithm to segment retinal vasculature and calculate Df. Multiple linear and logistic regression models were used to assess the associations of retinal vascular Df with systemic and ocular parameters.

Results

AI-based quantification of retinal vascular Df was successfully performed in 3,298 participants (95.1% of 3,468 participants), demonstrating high model performance: segmentation accuracy (0.9660), sensitivity (0.8879), specificity (0.9743), and intersection-over-union (IoU) (0.7110). The mean Df was 1.51 ± 0.09 (median: 1.53; interquartile range: 1.50–1.55). In multiple linear regression analysis, reduced Df was significantly associated with older age (standardized regression coefficient (sβ) = −2.346; P < 0.001), higher systolic blood pressure (sβ = −0.341; P < 0.001), smaller hip circumference (sβ = 0.518; P = 0.014), lower equivalent diopter (sβ = 3.589; P < 0.001), thinner retinal nerve fiber layer thickness (sβ = 0.390; P = 0.002), smaller arteriovenous ratio (sβ = 524.590; P < 0.001), and thinner subfoveal choroidal thickness (sβ = 0.071; P < 0.001). In the logistic regression model, the risk prevalence of hypertension increased with the decrease in Df (OR = 0.853, 95% CI: 0.651–0.801).

Conclusion

AI-powered Df analysis may be used as a novel quantitative platform for characterizing retinal microvascular morphological alterations.
基于人工智能的视网膜血管分形维数量化及其影响因素的回顾性研究
分形维数(Df)量化了血管网络的复杂性和空间填充密度,为微血管病理评估提供了一种非侵入性的生物标志物。我们的目标是建立一个人工智能(AI)驱动的框架,用于自动定量Df,并研究其在北京眼科研究的一般人群中的临床意义。方法回顾性研究采用2011年北京眼科研究的数据。采用人工智能算法对符合质量标准的眼底图像进行分割,并计算Df。使用多元线性和逻辑回归模型来评估视网膜血管Df与系统和眼部参数的关系。结果3298名受试者(3468名受试者中的95.1%)成功进行了基于人工智能的视网膜血管Df定量,显示出较高的模型性能:分割精度(0.9660)、灵敏度(0.8879)、特异性(0.9743)和交叉-超联合(IoU)(0.7110)。平均Df为1.51±0.09(中位数:1.53;四分位间距:1.50-1.55)。在多元线性回归分析中,Df的降低与年龄的增长显著相关(标准化回归系数(sβ) = - 2.346;P < 0.001)、较高的收缩压(sβ = - 0.341; P < 0.001)、较小的臀围(sβ = 0.518; P = 0.014)、较低的等效屈光度(sβ = 3.589; P < 0.001)、较薄的视网膜神经纤维层厚度(sβ = 0.390; P = 0.002)、较小的动静脉比(sβ = 524.590; P < 0.001)和较薄的中央凹下脉络膜厚度(sβ = 0.071; P < 0.001)。在logistic回归模型中,高血压风险患病率随着Df的降低而增加(OR = 0.853, 95% CI: 0.651-0.801)。结论人工智能驱动的Df分析可作为表征视网膜微血管形态变化的一种新的定量平台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Intelligent medicine
Intelligent medicine Surgery, Radiology and Imaging, Artificial Intelligence, Biomedical Engineering
CiteScore
5.20
自引率
0.00%
发文量
19
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书