Variability in preoperative planning software for shoulder arthroplasty

IF 2 Q2 Medicine
JSES International Pub Date : 2026-05-01 Epub Date: 2026-03-23 DOI:10.1016/j.jseint.2026.101698
Ana R. Senra MD , Diogo Tomaz MD , Diogo S. Gomes MD , Nuno S. Gomes MD , Nuno Sevivas PhD , Francisco Serdoura MD , André Pinho PhD , Alberto Vieira MD , Nuno Neves PhD , Carlos M. Dias PhD , Daniela Linhares PhD , Maria J. Leite PhD , Manuel R. Silva PhD
{"title":"Variability in preoperative planning software for shoulder arthroplasty","authors":"Ana R. Senra MD ,&nbsp;Diogo Tomaz MD ,&nbsp;Diogo S. Gomes MD ,&nbsp;Nuno S. Gomes MD ,&nbsp;Nuno Sevivas PhD ,&nbsp;Francisco Serdoura MD ,&nbsp;André Pinho PhD ,&nbsp;Alberto Vieira MD ,&nbsp;Nuno Neves PhD ,&nbsp;Carlos M. Dias PhD ,&nbsp;Daniela Linhares PhD ,&nbsp;Maria J. Leite PhD ,&nbsp;Manuel R. Silva PhD","doi":"10.1016/j.jseint.2026.101698","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Three-dimensional preoperative planning is increasingly used in shoulder arthroplasty to optimize implant selection and component positioning. Planning platforms rely on either automated best-fit sphere algorithms or manual landmark-based methods to characterize glenoid morphology, potentially introducing variability. This study aimed to compare 5 commercially available planning platforms and to determine whether differences in analytical algorithms explain intersoftware variability.</div></div><div><h3>Methods</h3><div>Thirty-three patients were included. Preoperative computed tomography scans were analyzed using Blueprint system (Stryker, Kalamazoo, MI, USA), Equinoxe Planning App (Exactech, Gainesville, FL, USA), Signature ONE Surgical Planning System (Zimmer Biomet, Warsaw, IN, USA), MyShoulder system (Medacta, Castel San Pietro, Switzerland), and LimaCorporate Pre-Op Planning Software (LimaCorporate/Enovis, San Daniele del Friuli, Udine, Italy). Glenoid version, inclination, and humeral head subluxation were assessed. Data analysis included a group evaluation for each variable and pairwise comparisons between software. A comparative analysis between automated and manual assessment methods was performed.</div></div><div><h3>Results</h3><div>Significant differences were found between platforms for version (<em>P</em> &lt; .001), inclination (<em>P</em> = .015), and subluxation (<em>P</em> = .032). Agreement was high for subluxation (intraclass correlation coefficient [ICC] = 0.826), moderate to high for version (ICC = 0.749), and low for inclination (ICC = 0.267). Pairwise agreement ranged from 45.5 to 97% for version (highest between Blueprint and LimaCorporate), 30.3–90.9% for inclination, and 60.6–75.8% for subluxation (lowest between Blueprint and LimaCorporate).</div></div><div><h3>Conclusion</h3><div>Significant variability exists between preoperative planning software, particularly for inclination. Automated software demonstrated the highest concordance for version but the lowest concordance for subluxation. These results suggest that, even with similar analytical algorithms, uniformity between software is lacking, potentially impacting surgical planning. Methodological standardization is essential to improve reliability and reproducibility of shoulder arthroplasty planning. Surgeons should consider this variability when planning shoulder arthroplasty and interpreting studies with different planning platforms.</div></div>","PeriodicalId":34444,"journal":{"name":"JSES International","volume":"10 3","pages":"Article 101698"},"PeriodicalIF":2.0000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSES International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666638326000836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/23 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Three-dimensional preoperative planning is increasingly used in shoulder arthroplasty to optimize implant selection and component positioning. Planning platforms rely on either automated best-fit sphere algorithms or manual landmark-based methods to characterize glenoid morphology, potentially introducing variability. This study aimed to compare 5 commercially available planning platforms and to determine whether differences in analytical algorithms explain intersoftware variability.

Methods

Thirty-three patients were included. Preoperative computed tomography scans were analyzed using Blueprint system (Stryker, Kalamazoo, MI, USA), Equinoxe Planning App (Exactech, Gainesville, FL, USA), Signature ONE Surgical Planning System (Zimmer Biomet, Warsaw, IN, USA), MyShoulder system (Medacta, Castel San Pietro, Switzerland), and LimaCorporate Pre-Op Planning Software (LimaCorporate/Enovis, San Daniele del Friuli, Udine, Italy). Glenoid version, inclination, and humeral head subluxation were assessed. Data analysis included a group evaluation for each variable and pairwise comparisons between software. A comparative analysis between automated and manual assessment methods was performed.

Results

Significant differences were found between platforms for version (P < .001), inclination (P = .015), and subluxation (P = .032). Agreement was high for subluxation (intraclass correlation coefficient [ICC] = 0.826), moderate to high for version (ICC = 0.749), and low for inclination (ICC = 0.267). Pairwise agreement ranged from 45.5 to 97% for version (highest between Blueprint and LimaCorporate), 30.3–90.9% for inclination, and 60.6–75.8% for subluxation (lowest between Blueprint and LimaCorporate).

Conclusion

Significant variability exists between preoperative planning software, particularly for inclination. Automated software demonstrated the highest concordance for version but the lowest concordance for subluxation. These results suggest that, even with similar analytical algorithms, uniformity between software is lacking, potentially impacting surgical planning. Methodological standardization is essential to improve reliability and reproducibility of shoulder arthroplasty planning. Surgeons should consider this variability when planning shoulder arthroplasty and interpreting studies with different planning platforms.
肩关节置换术术前计划软件的可变性
三维术前规划越来越多地用于肩关节置换术,以优化植入物的选择和部件的定位。规划平台依赖于自动最佳拟合球体算法或手动基于地标的方法来表征关节盂形态,这可能会引入可变性。本研究旨在比较5个商业上可用的规划平台,并确定分析算法的差异是否解释了软件间的可变性。方法纳入33例患者。术前计算机断层扫描分析使用Blueprint系统(Stryker, Kalamazoo, MI, USA)、equinox Planning App (Exactech, Gainesville, FL, USA)、Signature ONE手术计划系统(Zimmer Biomet, Warsaw, IN, USA)、MyShoulder系统(Medacta, Castel San Pietro, Switzerland)和limacorate术前计划软件(limacorate /Enovis, San Daniele del Friuli, Udine, Italy)。评估关节盂内翻、倾斜和肱骨头半脱位。数据分析包括对每个变量的组评价和软件之间的两两比较。对自动评估方法和人工评估方法进行了比较分析。结果不同平台在版本(P < 0.001)、倾斜度(P = 0.015)和半脱位(P = 0.032)方面存在显著差异。半脱位的一致性较高(类内相关系数[ICC] = 0.826),版本的一致性中等至高(ICC = 0.749),倾角的一致性较低(ICC = 0.267)。版本的两两一致性为45.5 - 97% (Blueprint和limacorate之间最高),倾角为30.3-90.9%,半脱位为60.6-75.8% (Blueprint和limacorate之间最低)。结论术前规划软件之间存在显著差异,尤其是倾角。自动化软件显示版本的一致性最高,但半脱位的一致性最低。这些结果表明,即使使用类似的分析算法,软件之间也缺乏一致性,这可能会影响手术计划。方法标准化对于提高肩关节置换术计划的可靠性和可重复性至关重要。外科医生在计划肩关节置换术和解释不同计划平台的研究时应考虑到这种可变性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JSES International
JSES International Medicine-Surgery
CiteScore
2.80
自引率
0.00%
发文量
174
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书