Ana R. Senra MD , Diogo Tomaz MD , Diogo S. Gomes MD , Nuno S. Gomes MD , Nuno Sevivas PhD , Francisco Serdoura MD , André Pinho PhD , Alberto Vieira MD , Nuno Neves PhD , Carlos M. Dias PhD , Daniela Linhares PhD , Maria J. Leite PhD , Manuel R. Silva PhD
{"title":"Variability in preoperative planning software for shoulder arthroplasty","authors":"Ana R. Senra MD , Diogo Tomaz MD , Diogo S. Gomes MD , Nuno S. Gomes MD , Nuno Sevivas PhD , Francisco Serdoura MD , André Pinho PhD , Alberto Vieira MD , Nuno Neves PhD , Carlos M. Dias PhD , Daniela Linhares PhD , Maria J. Leite PhD , Manuel R. Silva PhD","doi":"10.1016/j.jseint.2026.101698","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Three-dimensional preoperative planning is increasingly used in shoulder arthroplasty to optimize implant selection and component positioning. Planning platforms rely on either automated best-fit sphere algorithms or manual landmark-based methods to characterize glenoid morphology, potentially introducing variability. This study aimed to compare 5 commercially available planning platforms and to determine whether differences in analytical algorithms explain intersoftware variability.</div></div><div><h3>Methods</h3><div>Thirty-three patients were included. Preoperative computed tomography scans were analyzed using Blueprint system (Stryker, Kalamazoo, MI, USA), Equinoxe Planning App (Exactech, Gainesville, FL, USA), Signature ONE Surgical Planning System (Zimmer Biomet, Warsaw, IN, USA), MyShoulder system (Medacta, Castel San Pietro, Switzerland), and LimaCorporate Pre-Op Planning Software (LimaCorporate/Enovis, San Daniele del Friuli, Udine, Italy). Glenoid version, inclination, and humeral head subluxation were assessed. Data analysis included a group evaluation for each variable and pairwise comparisons between software. A comparative analysis between automated and manual assessment methods was performed.</div></div><div><h3>Results</h3><div>Significant differences were found between platforms for version (<em>P</em> < .001), inclination (<em>P</em> = .015), and subluxation (<em>P</em> = .032). Agreement was high for subluxation (intraclass correlation coefficient [ICC] = 0.826), moderate to high for version (ICC = 0.749), and low for inclination (ICC = 0.267). Pairwise agreement ranged from 45.5 to 97% for version (highest between Blueprint and LimaCorporate), 30.3–90.9% for inclination, and 60.6–75.8% for subluxation (lowest between Blueprint and LimaCorporate).</div></div><div><h3>Conclusion</h3><div>Significant variability exists between preoperative planning software, particularly for inclination. Automated software demonstrated the highest concordance for version but the lowest concordance for subluxation. These results suggest that, even with similar analytical algorithms, uniformity between software is lacking, potentially impacting surgical planning. Methodological standardization is essential to improve reliability and reproducibility of shoulder arthroplasty planning. Surgeons should consider this variability when planning shoulder arthroplasty and interpreting studies with different planning platforms.</div></div>","PeriodicalId":34444,"journal":{"name":"JSES International","volume":"10 3","pages":"Article 101698"},"PeriodicalIF":2.0000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSES International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666638326000836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/23 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Three-dimensional preoperative planning is increasingly used in shoulder arthroplasty to optimize implant selection and component positioning. Planning platforms rely on either automated best-fit sphere algorithms or manual landmark-based methods to characterize glenoid morphology, potentially introducing variability. This study aimed to compare 5 commercially available planning platforms and to determine whether differences in analytical algorithms explain intersoftware variability.
Methods
Thirty-three patients were included. Preoperative computed tomography scans were analyzed using Blueprint system (Stryker, Kalamazoo, MI, USA), Equinoxe Planning App (Exactech, Gainesville, FL, USA), Signature ONE Surgical Planning System (Zimmer Biomet, Warsaw, IN, USA), MyShoulder system (Medacta, Castel San Pietro, Switzerland), and LimaCorporate Pre-Op Planning Software (LimaCorporate/Enovis, San Daniele del Friuli, Udine, Italy). Glenoid version, inclination, and humeral head subluxation were assessed. Data analysis included a group evaluation for each variable and pairwise comparisons between software. A comparative analysis between automated and manual assessment methods was performed.
Results
Significant differences were found between platforms for version (P < .001), inclination (P = .015), and subluxation (P = .032). Agreement was high for subluxation (intraclass correlation coefficient [ICC] = 0.826), moderate to high for version (ICC = 0.749), and low for inclination (ICC = 0.267). Pairwise agreement ranged from 45.5 to 97% for version (highest between Blueprint and LimaCorporate), 30.3–90.9% for inclination, and 60.6–75.8% for subluxation (lowest between Blueprint and LimaCorporate).
Conclusion
Significant variability exists between preoperative planning software, particularly for inclination. Automated software demonstrated the highest concordance for version but the lowest concordance for subluxation. These results suggest that, even with similar analytical algorithms, uniformity between software is lacking, potentially impacting surgical planning. Methodological standardization is essential to improve reliability and reproducibility of shoulder arthroplasty planning. Surgeons should consider this variability when planning shoulder arthroplasty and interpreting studies with different planning platforms.