{"title":"Skin tone corrected pulse oximetry models evaluated through reflective pulsatile Monte Carlo simulations.","authors":"Yan Tung Nicholas Chan, Megh Rathod, Daniel Franklin","doi":"10.1117/1.BIOS.2.3.032507","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Skin tone bias in pulse oximetry is frequently reported to lead to overestimation of arterial blood oxygen saturation ( <math> <mrow> <msub><mrow><mi>SpO</mi></mrow> <mrow><mn>2</mn></mrow> </msub> </mrow> </math> ) in individuals with darker skin tones. We introduce clinically applicable, skin tone corrected pulse oximetry models to address this disparity and promote more equitable patient care.</p><p><strong>Aim: </strong>We aim to mitigate skin tone bias in pulse oximetry by integrating a melanin correction factor into the conventional ratio-of-ratios approach. We employ pulsatile Monte Carlo simulation to systematically map the \"ratio of ratios\" ( <math><mrow><mi>R</mi></mrow> </math> ) to <math> <mrow><msub><mi>SaO</mi> <mn>2</mn></msub> </mrow> </math> across varying melanin concentrations, thereby enabling comprehensive quantitative assessments of different <math> <mrow><msub><mi>SpO</mi> <mn>2</mn></msub> </mrow> </math> correction models.</p><p><strong>Approach: </strong>A six-layered skin model is implemented to approximate the microstructure of human skin, allowing diffuse reflectance computations through Monte Carlo methods. Pulsatile effects are captured by modeling diastolic and systolic phrases, facilitating the calculation of <math><mrow><mi>R</mi></mrow> </math> values under diverse <math> <mrow><msub><mi>SaO</mi> <mn>2</mn></msub> </mrow> </math> and melanin conditions.</p><p><strong>Results: </strong>Skin tone induced error is quantified and mitigated by incorporating a melanin correction factor into conventional ratio-of-ratios. The inclusion of a melanin-dependent variable results in a substantial reduction in skin tone bias.</p><p><strong>Conclusions: </strong>Monte Carlo simulations offer precise control over both melanin content and <math> <mrow><msub><mi>SpO</mi> <mn>2</mn></msub> </mrow> </math> , conditions that are challenging to replicate <i>in vivo</i>, and enable the development of robust <math> <mrow><msub><mi>SpO</mi> <mn>2</mn></msub> </mrow> </math> correction models. These findings represent a valuable step toward more equitable pulse oximetry practices, ultimately improving patient care across diverse skin tones.</p>","PeriodicalId":519981,"journal":{"name":"Biophotonics discovery","volume":"2 3","pages":"032507"},"PeriodicalIF":0.0000,"publicationDate":"2025-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13052488/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biophotonics discovery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/1.BIOS.2.3.032507","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Significance: Skin tone bias in pulse oximetry is frequently reported to lead to overestimation of arterial blood oxygen saturation ( SpO 2 ) in individuals with darker skin tones. We introduce clinically applicable, skin tone corrected pulse oximetry models to address this disparity and promote more equitable patient care.

Aim: We aim to mitigate skin tone bias in pulse oximetry by integrating a melanin correction factor into the conventional ratio-of-ratios approach. We employ pulsatile Monte Carlo simulation to systematically map the "ratio of ratios" ( R ) to SaO 2 across varying melanin concentrations, thereby enabling comprehensive quantitative assessments of different SpO 2 correction models.

Approach: A six-layered skin model is implemented to approximate the microstructure of human skin, allowing diffuse reflectance computations through Monte Carlo methods. Pulsatile effects are captured by modeling diastolic and systolic phrases, facilitating the calculation of R values under diverse SaO 2 and melanin conditions.

Results: Skin tone induced error is quantified and mitigated by incorporating a melanin correction factor into conventional ratio-of-ratios. The inclusion of a melanin-dependent variable results in a substantial reduction in skin tone bias.

Conclusions: Monte Carlo simulations offer precise control over both melanin content and SpO 2 , conditions that are challenging to replicate in vivo, and enable the development of robust SpO 2 correction models. These findings represent a valuable step toward more equitable pulse oximetry practices, ultimately improving patient care across diverse skin tones.

肤色校正脉搏血氧测量模型通过反射脉冲蒙特卡罗模拟评估。
意义:在脉搏血氧测定中,经常有报道称肤色偏倚会导致深肤色个体动脉血氧饱和度(spo2)的高估。我们介绍临床适用,肤色校正脉搏血氧仪模型,以解决这一差距,促进更公平的病人护理。目的:我们的目标是通过将黑色素校正因子整合到传统的比率方法中来减轻脉搏血氧测量中的肤色偏差。我们采用脉动蒙特卡罗模拟系统地绘制了不同黑色素浓度下的“比率之比”(R)与SaO 2的关系,从而能够对不同的SpO 2校正模型进行全面的定量评估。方法:实现六层皮肤模型来近似人体皮肤的微观结构,允许通过蒙特卡罗方法进行漫反射计算。通过模拟舒张期和收缩期来捕捉搏动效应,便于计算不同SaO 2和黑色素条件下的R值。结果:通过将黑色素校正因子纳入常规比率,可以量化和减轻肤色引起的误差。纳入黑色素相关变量可显著减少肤色偏倚。结论:蒙特卡罗模拟提供了对黑色素含量和SpO 2的精确控制,这是在体内复制具有挑战性的条件,并且能够开发强大的SpO 2校正模型。这些发现代表了朝着更公平的脉搏血氧测量实践迈出的有价值的一步,最终改善了不同肤色的患者护理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书