{"title":"A Fault Diagnosis and Fault-Tolerant Control Method for Open-Circuit Fault of Excitation Winding Converter in DSEM Drive System","authors":"Yi Lu;Qingyun Chang","doi":"10.1109/JESTPE.2026.3687198","DOIUrl":null,"url":null,"abstract":"This article proposes a fault location and fault-tolerant control method for the open-circuit fault of the excitation winding converter in the doubly salient electromagnetic motor (DSEM) drive system. First, by rearranging the placement of the excitation current sensor and analyzing the change characteristics of the sampled current values before and after the excitation winding converter open-circuit fault, the faulty switch is quickly located. Then, fault-tolerant control strategies for the armature winding and excitation winding converter are designed for open-circuit faults in the excitation winding converter switches at different locations. This ensures that the output torque of the DSEM remains unchanged before and after fault-tolerant control, thus guaranteeing smooth motor operation. Simultaneously, the switching moment of the armature winding converter control strategy is optimized after the occurrence of the excitation winding converter open-circuit fault, in order to prevent the motor from outputting negative torque during the switching process. The proposed method can rapidly locate the faulty switch in the excitation winding converter without the need for additional sensors. It ensures that the motor maintains a consistent output torque before and after fault-tolerant operation, thereby guaranteeing the load-carrying capability of the motor. Finally, experiments conducted on a 12/8 three-phase DSEM verify the effectiveness and practicality of the proposed method.","PeriodicalId":13093,"journal":{"name":"IEEE Journal of Emerging and Selected Topics in Power Electronics","volume":"14 5","pages":"6720-6731"},"PeriodicalIF":5.7000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Emerging and Selected Topics in Power Electronics","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11494777/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

This article proposes a fault location and fault-tolerant control method for the open-circuit fault of the excitation winding converter in the doubly salient electromagnetic motor (DSEM) drive system. First, by rearranging the placement of the excitation current sensor and analyzing the change characteristics of the sampled current values before and after the excitation winding converter open-circuit fault, the faulty switch is quickly located. Then, fault-tolerant control strategies for the armature winding and excitation winding converter are designed for open-circuit faults in the excitation winding converter switches at different locations. This ensures that the output torque of the DSEM remains unchanged before and after fault-tolerant control, thus guaranteeing smooth motor operation. Simultaneously, the switching moment of the armature winding converter control strategy is optimized after the occurrence of the excitation winding converter open-circuit fault, in order to prevent the motor from outputting negative torque during the switching process. The proposed method can rapidly locate the faulty switch in the excitation winding converter without the need for additional sensors. It ensures that the motor maintains a consistent output torque before and after fault-tolerant operation, thereby guaranteeing the load-carrying capability of the motor. Finally, experiments conducted on a 12/8 three-phase DSEM verify the effectiveness and practicality of the proposed method.
DSEM驱动系统励磁绕组变换器开路故障诊断与容错控制方法
针对双凸极电磁电机驱动系统中励磁绕组变换器的开路故障,提出了一种故障定位和容错控制方法。首先,通过重新布置励磁电流传感器的位置,分析励磁绕组变换器开路故障前后采样电流值的变化特征,快速定位故障开关;然后,针对励磁绕组变换器开关在不同位置的开路故障,设计了电枢绕组和励磁绕组变换器的容错控制策略。这保证了容错控制前后DSEM的输出转矩保持不变,从而保证了电机的平稳运行。同时,在励磁绕组变换器发生开路故障后,优化电枢绕组变换器的开关力矩控制策略,防止电机在开关过程中输出负转矩。该方法可以快速定位励磁绕组变换器中的故障开关,而不需要额外的传感器。保证了电机在容错运行前后保持一致的输出转矩,从而保证了电机的承载能力。最后,在12/8三相DSEM上进行了实验,验证了该方法的有效性和实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
12.50
自引率
9.10%
发文量
547
审稿时长
3 months
期刊介绍: The aim of the journal is to enable the power electronics community to address the emerging and selected topics in power electronics in an agile fashion. It is a forum where multidisciplinary and discriminating technologies and applications are discussed by and for both practitioners and researchers on timely topics in power electronics from components to systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书