Variability in Tissue Interface Temperature During Pulse Field Atrial Ablation: Implications for Real-Time Contact Assessment.

IF 9.3 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
John R Power, Keita Watanabe, Masaya Shinohara, Fengyuan Yu, Srinivas Dukkipati, Daniel R Musikantow, William Whang, Joshua Lampert, Abhishek Maan, Maryam Saleem, Ariel Banai, Connor P Oates, Sai Krishna Reddy Seemala, Vivek Y Reddy, Jacob S Koruth
{"title":"Variability in Tissue Interface Temperature During Pulse Field Atrial Ablation: Implications for Real-Time Contact Assessment.","authors":"John R Power, Keita Watanabe, Masaya Shinohara, Fengyuan Yu, Srinivas Dukkipati, Daniel R Musikantow, William Whang, Joshua Lampert, Abhishek Maan, Maryam Saleem, Ariel Banai, Connor P Oates, Sai Krishna Reddy Seemala, Vivek Y Reddy, Jacob S Koruth","doi":"10.1161/CIRCEP.125.014310","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pulsed field ablation (PFA) can generate low-intensity catheter-tissue interface heating. Recently, a large-focal PFA catheter able to measure the tip-tissue interface temperature has become available. Accordingly, we aimed to characterize the electrode tip-tissue interface temperature dynamics during PFA.</p><p><strong>Methods: </strong>A retrospective single-center study evaluated PFA lesions in 41 consecutive patients undergoing atrial fibrillation ablation using the lattice-tip catheter. Lesions were grouped by anatomic location with interface temperatures measured via catheter tip thermocouples. The association of predictors with lesion temperatures was evaluated with a mixed-effects model. An analysis of lesion dimensions and interface temperatures was also performed in swine.</p><p><strong>Results: </strong>Among 41 patients, 2779 pulse field lesions were analyzed. Mean peak temperature was 41.7±2.2 °C (range, 37.2 °C-52.8 °C) and average temperature was 39.5±1.4 °C (range, 36.4 °C-46.9 °C). Temperatures exceeded 50 °C in 10 of 2779 (0.4%) lesions, most often in the anterosuperior left superior pulmonary vein (5/10). Univariate analysis showed peak temperature was positively associated with previous lesion temperature (<i>r</i>=0.65 [95% CI, 0.63-0.67]; <i>P</i><0.001) and had weak associations with time between lesions (<i>r</i>=-0.15 [-0.19 to -0.11]; <i>P</i><0.001) and percentage impedance drop (<i>r</i>=0.20 [95% CI, 0.16-0.23]; <i>P</i><0.001). Even after multivariable analysis, the peak temperature remained significantly lowest at the right carina (39.7 °C), anterosuperior right superior pulmonary vein (40.9 °C), and right superior pulmonary vein roof (40.5 °C) locations. Swine demonstrated a moderately strong association between lesion depth with peak temperature (<i>R</i>=0.53 [95% CI, 0.20-0.75]; <i>P</i>=0.003) and average temperature (<i>R</i>=0.49 [95% CI, 0.16-0.73]; <i>P</i>=0.007).</p><p><strong>Conclusions: </strong>Lattice-tip temperatures during PFA vary substantially, with right superior pulmonary vein sites often demonstrating a blunted temperature response compared with other sites. Peak and average temperatures correlated with lesion depth.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e014310"},"PeriodicalIF":9.3000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.125.014310","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Pulsed field ablation (PFA) can generate low-intensity catheter-tissue interface heating. Recently, a large-focal PFA catheter able to measure the tip-tissue interface temperature has become available. Accordingly, we aimed to characterize the electrode tip-tissue interface temperature dynamics during PFA.

Methods: A retrospective single-center study evaluated PFA lesions in 41 consecutive patients undergoing atrial fibrillation ablation using the lattice-tip catheter. Lesions were grouped by anatomic location with interface temperatures measured via catheter tip thermocouples. The association of predictors with lesion temperatures was evaluated with a mixed-effects model. An analysis of lesion dimensions and interface temperatures was also performed in swine.

Results: Among 41 patients, 2779 pulse field lesions were analyzed. Mean peak temperature was 41.7±2.2 °C (range, 37.2 °C-52.8 °C) and average temperature was 39.5±1.4 °C (range, 36.4 °C-46.9 °C). Temperatures exceeded 50 °C in 10 of 2779 (0.4%) lesions, most often in the anterosuperior left superior pulmonary vein (5/10). Univariate analysis showed peak temperature was positively associated with previous lesion temperature (r=0.65 [95% CI, 0.63-0.67]; P<0.001) and had weak associations with time between lesions (r=-0.15 [-0.19 to -0.11]; P<0.001) and percentage impedance drop (r=0.20 [95% CI, 0.16-0.23]; P<0.001). Even after multivariable analysis, the peak temperature remained significantly lowest at the right carina (39.7 °C), anterosuperior right superior pulmonary vein (40.9 °C), and right superior pulmonary vein roof (40.5 °C) locations. Swine demonstrated a moderately strong association between lesion depth with peak temperature (R=0.53 [95% CI, 0.20-0.75]; P=0.003) and average temperature (R=0.49 [95% CI, 0.16-0.73]; P=0.007).

Conclusions: Lattice-tip temperatures during PFA vary substantially, with right superior pulmonary vein sites often demonstrating a blunted temperature response compared with other sites. Peak and average temperatures correlated with lesion depth.

脉冲场心房消融过程中组织界面温度的变化:实时接触评估的意义。
背景:脉冲场消融(PFA)可以产生低强度的导管-组织界面加热。最近,一种能够测量尖端组织界面温度的大焦点PFA导管已经可用。因此,我们旨在表征PFA过程中电极尖端-组织界面的温度动态。方法:一项回顾性单中心研究评估了41例连续接受格尖导管房颤消融的PFA病变。病变按解剖位置分组,通过导管尖端热电偶测量界面温度。预测因子与病变温度的关联用混合效应模型进行了评估。对猪的损伤尺寸和界面温度也进行了分析。结果:41例患者共分析了2779个脉场病变。平均峰值温度为41.7±2.2°C(范围37.2°C-52.8°C),平均温度为39.5±1.4°C(范围36.4°C-46.9°C)。2779例(0.4%)病灶中有10例温度超过50℃,最常见于左上肺静脉前(5/10)。单因素分析显示,峰值温度与既往病变温度(r=0.65 [95% CI, 0.63-0.67], Pr=-0.15[-0.19至-0.11],Pr=0.20 [95% CI, 0.16-0.23], Pr= 0.53 [95% CI, 0.20-0.75], P=0.003)和平均温度(r= 0.49 [95% CI, 0.16-0.73], P=0.007)呈正相关。结论:PFA期间晶格尖端温度变化很大,与其他部位相比,右上肺静脉部位通常表现出迟钝的温度反应。峰值和平均温度与病变深度相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
13.70
自引率
4.80%
发文量
187
审稿时长
4-8 weeks
期刊介绍: Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书