{"title":"Real-Life Application of a Point-of-Care Biosensor for Phenylalanine in Patients With Phenylketonuria.","authors":"Corentin Gondrand, Anna T Reischl-Hajiabadi, Estelle Bonedeau, Nicolas Weiß, Gerd Schneider, Maurice Fahn, Frederic Myers, Philipp Minel Städle, Kathrin Jeltsch, Georg F Hoffmann, Jürgen G Okun, Dorothea Haas, Sven F Garbade, Kai Johnsson, Thomas Opladen","doi":"10.1002/jimd.70187","DOIUrl":null,"url":null,"abstract":"<p><p>Phenylketonuria (PKU) is a rare metabolic disorder causing elevated phenylalanine (PHE) levels requiring lifelong dietary or pharmacological management and regular monitoring. Current PHE monitoring methods, such as tandem mass spectrometry (FIA-MS/MS), are laboratory and sample transport-dependent, leading to delays in obtaining results. This highlights the need for accessible point-of-care (PoC) solutions. Building on a previously developed bioluminescence-based PHE quantification method, we created a PoC PHE sensor integrated with a smartphone app (phenyx app) for real-time monitoring and data sharing. In a clinical study with PKU patients, we evaluated the reliability of the sensor and the app by comparing at-home PHE measurements with dried blood samples (DBS) analyzed using the gold standard FIA-MS/MS. We also assessed time differences between sampling and results, sensor practicality, and user experience. Forty-seven PKU patients (median age 10.0 years, range 0.7-53.4) performed one supervised and four at-home measurements using the PHE sensor, alongside DBS sampling for FIA-MS/MS. The sensor showed higher PHE values than FIA-MS/MS, with a mean difference of 84.8 μmol/L (p = 0.0017). Variability was influenced by test supervision (clinic vs. home) and test kit age (greater difference in older batches, p = 0.001). Usability of the PHE sensor and phenyx app was rated favorably; all patients preferred the PHE sensor over laboratory testing. PoC measurement using the PHE sensor and phenyx app is feasible, reliable, and provides rapid results comparable to FIA-MS/MS, representing a key step toward patient self-testing. Trial Registration: NCT05998109, NCT06940193, DRKS00031972.</p>","PeriodicalId":16281,"journal":{"name":"Journal of Inherited Metabolic Disease","volume":"49 3","pages":"e70187"},"PeriodicalIF":3.8000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13086054/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Inherited Metabolic Disease","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jimd.70187","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Phenylketonuria (PKU) is a rare metabolic disorder causing elevated phenylalanine (PHE) levels requiring lifelong dietary or pharmacological management and regular monitoring. Current PHE monitoring methods, such as tandem mass spectrometry (FIA-MS/MS), are laboratory and sample transport-dependent, leading to delays in obtaining results. This highlights the need for accessible point-of-care (PoC) solutions. Building on a previously developed bioluminescence-based PHE quantification method, we created a PoC PHE sensor integrated with a smartphone app (phenyx app) for real-time monitoring and data sharing. In a clinical study with PKU patients, we evaluated the reliability of the sensor and the app by comparing at-home PHE measurements with dried blood samples (DBS) analyzed using the gold standard FIA-MS/MS. We also assessed time differences between sampling and results, sensor practicality, and user experience. Forty-seven PKU patients (median age 10.0 years, range 0.7-53.4) performed one supervised and four at-home measurements using the PHE sensor, alongside DBS sampling for FIA-MS/MS. The sensor showed higher PHE values than FIA-MS/MS, with a mean difference of 84.8 μmol/L (p = 0.0017). Variability was influenced by test supervision (clinic vs. home) and test kit age (greater difference in older batches, p = 0.001). Usability of the PHE sensor and phenyx app was rated favorably; all patients preferred the PHE sensor over laboratory testing. PoC measurement using the PHE sensor and phenyx app is feasible, reliable, and provides rapid results comparable to FIA-MS/MS, representing a key step toward patient self-testing. Trial Registration: NCT05998109, NCT06940193, DRKS00031972.
期刊介绍:
The Journal of Inherited Metabolic Disease (JIMD) is the official journal of the Society for the Study of Inborn Errors of Metabolism (SSIEM). By enhancing communication between workers in the field throughout the world, the JIMD aims to improve the management and understanding of inherited metabolic disorders. It publishes results of original research and new or important observations pertaining to any aspect of inherited metabolic disease in humans and higher animals. This includes clinical (medical, dental and veterinary), biochemical, genetic (including cytogenetic, molecular and population genetic), experimental (including cell biological), methodological, theoretical, epidemiological, ethical and counselling aspects. The JIMD also reviews important new developments or controversial issues relating to metabolic disorders and publishes reviews and short reports arising from the Society''s annual symposia. A distinction is made between peer-reviewed scientific material that is selected because of its significance for other professionals in the field and non-peer- reviewed material that aims to be important, controversial, interesting or entertaining (“Extras”).