Ergonomic Considerations in Neonatal Cardiopulmonary Resuscitation: Implications for Practice.

IF 1.6
Helen Harrod Clark, Jennifer Parent-Nichols, Paula McWilliam, Brian King, Rodrigo Galindo, Louis P Halamek, Nicole K Yamada
{"title":"Ergonomic Considerations in Neonatal Cardiopulmonary Resuscitation: Implications for Practice.","authors":"Helen Harrod Clark, Jennifer Parent-Nichols, Paula McWilliam, Brian King, Rodrigo Galindo, Louis P Halamek, Nicole K Yamada","doi":"10.1097/ANC.0000000000001361","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Prolonged neonatal cardiopulmonary resuscitation (CPR) is critical for survival in cases of severe bradycardia due to asphyxia. High-performance CPR, emphasizing consistent compression depth and full recoil, improves survival rates.</p><p><strong>Purpose: </strong>This pilot study explored how environmental and provider-specific factors-including bed height, positioning, and anthropometry-affect the consistency of neonatal CPR using the 2-thumb technique.</p><p><strong>Methods: </strong>Twenty-two neonatal intensive care unit providers performed 2-minute CPR trials on a neonatal simulator under 2 conditions: self-selected bed height (\"choice\") and standardized bed height (100 cm, \"pre-set\"). Compression depth and recoil were recorded using simulator sensors. Postural changes and onset of sway were assessed via video analysis. Results from the head-of-bed position were compared with data from a prior side-of-bed study.</p><p><strong>Results: </strong>Chest recoil decreased over time in both bed-height conditions, potentially compromising CPR effectiveness. Bed height did not impact the number of postural changes or time to sway with a head-of-bed approach. Compared to the side-of-bed position, head-of-bed placement resulted in fewer postural changes and delayed onset of sway. In the choice condition, taller providers and those with longer reach preferred higher bed heights.</p><p><strong>Implications for practice and research: </strong>The head-of-bed approach may enhance motor performance by allowing pelvic stabilization against the bed, limiting lower-joint motion, and improving stability. However, this position may impair chest recoil over time, potentially reducing CPR effectiveness. Further research is needed to optimize ergonomic factors influencing neonatal resuscitation performance.</p>","PeriodicalId":520547,"journal":{"name":"Advances in neonatal care : official journal of the National Association of Neonatal Nurses","volume":" ","pages":"394-401"},"PeriodicalIF":1.6000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in neonatal care : official journal of the National Association of Neonatal Nurses","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ANC.0000000000001361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Prolonged neonatal cardiopulmonary resuscitation (CPR) is critical for survival in cases of severe bradycardia due to asphyxia. High-performance CPR, emphasizing consistent compression depth and full recoil, improves survival rates.

Purpose: This pilot study explored how environmental and provider-specific factors-including bed height, positioning, and anthropometry-affect the consistency of neonatal CPR using the 2-thumb technique.

Methods: Twenty-two neonatal intensive care unit providers performed 2-minute CPR trials on a neonatal simulator under 2 conditions: self-selected bed height ("choice") and standardized bed height (100 cm, "pre-set"). Compression depth and recoil were recorded using simulator sensors. Postural changes and onset of sway were assessed via video analysis. Results from the head-of-bed position were compared with data from a prior side-of-bed study.

Results: Chest recoil decreased over time in both bed-height conditions, potentially compromising CPR effectiveness. Bed height did not impact the number of postural changes or time to sway with a head-of-bed approach. Compared to the side-of-bed position, head-of-bed placement resulted in fewer postural changes and delayed onset of sway. In the choice condition, taller providers and those with longer reach preferred higher bed heights.

Implications for practice and research: The head-of-bed approach may enhance motor performance by allowing pelvic stabilization against the bed, limiting lower-joint motion, and improving stability. However, this position may impair chest recoil over time, potentially reducing CPR effectiveness. Further research is needed to optimize ergonomic factors influencing neonatal resuscitation performance.

新生儿心肺复苏的人体工程学考虑:对实践的影响。
背景:延长新生儿心肺复苏(CPR)是关键的生存的情况下,严重心动过缓,由于窒息。高性能CPR,强调一致的压缩深度和充分的后坐力,提高了生存率。目的:本初步研究探讨了环境和提供者特定因素(包括床高度、位置和人体测量)如何影响使用双拇指技术的新生儿心肺复苏术的一致性。方法:22名新生儿重症监护病房的医护人员在新生儿模拟器上进行了2分钟心肺复苏术试验,试验条件有两种:自我选择的床高(“选择”)和标准化的床高(100厘米,“预先设定”)。用模拟器传感器记录压缩深度和后坐力。通过视频分析评估姿势变化和摇摆的开始。将床头位置的结果与先前床边研究的数据进行比较。结果:在两种床高的情况下,胸部后坐力随着时间的推移而减少,这可能会影响心肺复苏术的效果。床的高度不影响体位变化的次数,也不影响头朝床的摇晃时间。与床边位置相比,床头位置导致较少的姿势变化和延迟的摇摆。在选择条件下,较高的提供者和较长的提供者更倾向于较高的床高。对实践和研究的启示:床头入路可以通过允许骨盆靠床稳定、限制下肢运动和提高稳定性来提高运动表现。然而,随着时间的推移,这种体位可能会损害胸部后坐力,潜在地降低心肺复苏术的效果。需要进一步研究优化影响新生儿复苏表现的人机工程学因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书