{"title":"Identifying the limitations of the 2015 NIOSH vapor containment performance protocol for assessing closed system transfer devices.","authors":"Lori T Armistead, Stephen F Eckel","doi":"10.1177/10781552261441766","DOIUrl":null,"url":null,"abstract":"<p><p>IntroductionThe purpose of this series of three studies was to identify the limitations of the 2015 NIOSH Vapor Containment Performance Protocol for Assessing Closed System Transfer Devices (CSTDs) as well as the variables that may impact results when testing CSTDs.MethodsTwo different lots of Equashield<sup>®</sup> CSTDs were tested in accordance with Task 2 of the protocol, using 70% isopropyl alcohol (IPA) as a challenge agent and either a Gasmet™ DX5000 Terra multigas FTIR analyzer or MIRAN<sup>®</sup> SapphIRe XL Infrared analyzer to measure IPA vapor concentrations. All studies were conducted in NIOSH-designed, custom-built testing chambers. Variables assessed to determine impact on results included: user technique, brand of IV bag, brand of IV administration line, where (inside or outside the chamber) IV bags, IV lines, and y-site adapter CSTDs were assembled, CSTD manufacturing dates, and analyzer type.ResultsThe variables that impacted testing results included user technique and experience, use or non-use of bulky gloves during y-site adapter-to-IV-line assembly, and analyzer. Variations in the brands of IV bags and IV administration lines and manufacturing dates of CSTDs did not impact the results.ConclusionBased on the known limitations of the 2015 NIOSH protocol, an improved testing protocol - with a better hazardous drug (HD) surrogate than IPA - is needed for assessing the true effectiveness of CSTDs in containing HDs. In the meantime, this protocol can be used to help CSTD manufacturers and/or end users isolate and mitigate potential weaknesses in their CSTD products and/or the compounding techniques used.</p>","PeriodicalId":16637,"journal":{"name":"Journal of Oncology Pharmacy Practice","volume":" ","pages":"10781552261441766"},"PeriodicalIF":0.9000,"publicationDate":"2026-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oncology Pharmacy Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10781552261441766","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

IntroductionThe purpose of this series of three studies was to identify the limitations of the 2015 NIOSH Vapor Containment Performance Protocol for Assessing Closed System Transfer Devices (CSTDs) as well as the variables that may impact results when testing CSTDs.MethodsTwo different lots of Equashield® CSTDs were tested in accordance with Task 2 of the protocol, using 70% isopropyl alcohol (IPA) as a challenge agent and either a Gasmet™ DX5000 Terra multigas FTIR analyzer or MIRAN® SapphIRe XL Infrared analyzer to measure IPA vapor concentrations. All studies were conducted in NIOSH-designed, custom-built testing chambers. Variables assessed to determine impact on results included: user technique, brand of IV bag, brand of IV administration line, where (inside or outside the chamber) IV bags, IV lines, and y-site adapter CSTDs were assembled, CSTD manufacturing dates, and analyzer type.ResultsThe variables that impacted testing results included user technique and experience, use or non-use of bulky gloves during y-site adapter-to-IV-line assembly, and analyzer. Variations in the brands of IV bags and IV administration lines and manufacturing dates of CSTDs did not impact the results.ConclusionBased on the known limitations of the 2015 NIOSH protocol, an improved testing protocol - with a better hazardous drug (HD) surrogate than IPA - is needed for assessing the true effectiveness of CSTDs in containing HDs. In the meantime, this protocol can be used to help CSTD manufacturers and/or end users isolate and mitigate potential weaknesses in their CSTD products and/or the compounding techniques used.

确定2015年NIOSH蒸汽密封性能协议用于评估封闭系统传输设备的局限性。
本系列三项研究的目的是确定2015年NIOSH蒸汽密封性能协议用于评估封闭系统传输设备(CSTDs)的局限性,以及测试CSTDs时可能影响结果的变量。方法根据协议的任务2测试两批Equashield®CSTDs,使用70%异丙醇(IPA)作为激发剂,使用Gasmet™DX5000 Terra多气体FTIR分析仪或MIRAN®SapphIRe XL红外分析仪测量IPA蒸气浓度。所有研究都在niosh设计的定制测试室中进行。为确定对结果的影响而评估的变量包括:用户技术、静脉输液袋的品牌、静脉输液管的品牌、静脉输液袋、静脉输液管和y位点适配器CSTD组装的位置(室内或室外)、CSTD制造日期和分析仪类型。影响检测结果的变量包括用户技术和经验,在y-site适配器到iv线组装过程中使用或不使用笨重的手套,以及分析仪。静脉输液袋和静脉输液线的品牌以及cstd的生产日期的变化对结果没有影响。结论基于2015年NIOSH方案的已知局限性,需要一个改进的测试方案-使用比IPA更好的危险药物(HD)替代品-来评估含有HD的cstd的真正有效性。同时,该协议可用于帮助CSTD制造商和/或最终用户隔离和减轻其CSTD产品和/或所使用的复合技术中的潜在弱点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.70
自引率
7.70%
发文量
276
期刊介绍: Journal of Oncology Pharmacy Practice is a peer-reviewed scholarly journal dedicated to educating health professionals about providing pharmaceutical care to patients with cancer. It is the official publication of the International Society for Oncology Pharmacy Practitioners (ISOPP). Publishing pertinent case reports and consensus guidelines...
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书