Multi-site distributed training with data protections for PET-based synthetic CT.

IF 3.5 2区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Kasper Jørgensen, Lauren Partin, Raghavan Ashok, Vijay Shah, Anders Bertil Rodell, Martin Bazik, Bruce Spottiswoode, Flemming Littrup Andersen
{"title":"Multi-site distributed training with data protections for PET-based synthetic CT.","authors":"Kasper Jørgensen, Lauren Partin, Raghavan Ashok, Vijay Shah, Anders Bertil Rodell, Martin Bazik, Bruce Spottiswoode, Flemming Littrup Andersen","doi":"10.1186/s40658-026-00868-2","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND: Accurate PET quantification relies on attenuation correction (AC), commonly performed using a linear attenuation map derived from a CT acquisition. However, CT can introduce misregistration artifacts and adds radiation dose. Synthetic CT (sCT) from non-attenuation corrected (NAC) PET offers a CT-less alternative, but training robust models requires multi-site data that may be difficult to share under privacy regulations. We aim to enable PET-based sCT training across sites without exposing data. METHODS: We built a federated learning (FL) framework and trained two sCT generators–a paired conditional GAN and a CycleGAN. Models were pretrained on a single-site cohort (Site 1, n = 425) and fine-tuned via FL using additional data from Site 1 (n = 25) and a second site with different scanners and reconstruction parameters (Site 2, n = 25). Performance was assessed on an internal hold-out set (Site 1, n = 91) and two external cohorts (Sites 3,4; n = 11, 10) using region-wise relative mean error (rME) of SUV in AC PET. RESULTS: Both models produced anatomically plausible sCT and AC PET with low errors when test data matched training distributions. FL fine-tuning improved robustness under distribution shift at Site 3, reducing errors across most regions, while maintaining comparable performance at Site 4 where protocols resembled the pretraining site. CONCLUSION: Multi-site FL is a feasible path to increase the generalizability of PET-based sCT while preserving data privacy. The proposed framework offers a practical template for training and deploying CT-less AC models across heterogeneous clinical environments. </p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2026-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13199553/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-026-00868-2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND: Accurate PET quantification relies on attenuation correction (AC), commonly performed using a linear attenuation map derived from a CT acquisition. However, CT can introduce misregistration artifacts and adds radiation dose. Synthetic CT (sCT) from non-attenuation corrected (NAC) PET offers a CT-less alternative, but training robust models requires multi-site data that may be difficult to share under privacy regulations. We aim to enable PET-based sCT training across sites without exposing data. METHODS: We built a federated learning (FL) framework and trained two sCT generators–a paired conditional GAN and a CycleGAN. Models were pretrained on a single-site cohort (Site 1, n = 425) and fine-tuned via FL using additional data from Site 1 (n = 25) and a second site with different scanners and reconstruction parameters (Site 2, n = 25). Performance was assessed on an internal hold-out set (Site 1, n = 91) and two external cohorts (Sites 3,4; n = 11, 10) using region-wise relative mean error (rME) of SUV in AC PET. RESULTS: Both models produced anatomically plausible sCT and AC PET with low errors when test data matched training distributions. FL fine-tuning improved robustness under distribution shift at Site 3, reducing errors across most regions, while maintaining comparable performance at Site 4 where protocols resembled the pretraining site. CONCLUSION: Multi-site FL is a feasible path to increase the generalizability of PET-based sCT while preserving data privacy. The proposed framework offers a practical template for training and deploying CT-less AC models across heterogeneous clinical environments.

基于pet的合成CT多站点分布式训练与数据保护。
背景:准确的PET定量依赖于衰减校正(AC),通常使用从CT采集得出的线性衰减图来执行。然而,CT可能会引入误配伪影并增加辐射剂量。来自非衰减校正(NAC) PET的合成CT (sCT)提供了一种无CT的替代方案,但训练健壮的模型需要多站点数据,在隐私法规下可能难以共享。我们的目标是在不暴露数据的情况下实现基于pet的sCT跨站点培训。方法:我们建立了一个联邦学习(FL)框架,并训练了两个sCT生成器——一个配对条件GAN和一个循环GAN。模型在单站点队列(Site 1, n = 425)上进行预训练,并通过FL使用来自Site 1 (n = 25)和具有不同扫描仪和重建参数的第二个站点(Site 2, n = 25)的额外数据进行微调。使用AC PET中SUV的区域相对平均误差(rME)在内部保留集(站点1,n = 91)和两个外部队列(站点3,4;n = 11, 10)上评估性能。结果:当测试数据与训练分布相匹配时,两种模型都产生了解剖学上合理的sCT和AC PET,误差很低。FL微调在Site 3的分布转移下提高了鲁棒性,减少了大多数区域的错误,同时在协议类似于预训练站点的Site 4保持了相当的性能。结论:在保护数据隐私的同时,多位点FL是一种可行的方法,可以提高基于pet的sCT的广泛性。提出的框架为跨异构临床环境训练和部署无ct AC模型提供了一个实用的模板。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
EJNMMI Physics
EJNMMI Physics Physics and Astronomy-Radiation
CiteScore
6.70
自引率
10.00%
发文量
78
审稿时长
13 weeks
期刊介绍: EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书