Kasper Jørgensen, Lauren Partin, Raghavan Ashok, Vijay Shah, Anders Bertil Rodell, Martin Bazik, Bruce Spottiswoode, Flemming Littrup Andersen
{"title":"Multi-site distributed training with data protections for PET-based synthetic CT.","authors":"Kasper Jørgensen, Lauren Partin, Raghavan Ashok, Vijay Shah, Anders Bertil Rodell, Martin Bazik, Bruce Spottiswoode, Flemming Littrup Andersen","doi":"10.1186/s40658-026-00868-2","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND: Accurate PET quantification relies on attenuation correction (AC), commonly performed using a linear attenuation map derived from a CT acquisition. However, CT can introduce misregistration artifacts and adds radiation dose. Synthetic CT (sCT) from non-attenuation corrected (NAC) PET offers a CT-less alternative, but training robust models requires multi-site data that may be difficult to share under privacy regulations. We aim to enable PET-based sCT training across sites without exposing data. METHODS: We built a federated learning (FL) framework and trained two sCT generators–a paired conditional GAN and a CycleGAN. Models were pretrained on a single-site cohort (Site 1, n = 425) and fine-tuned via FL using additional data from Site 1 (n = 25) and a second site with different scanners and reconstruction parameters (Site 2, n = 25). Performance was assessed on an internal hold-out set (Site 1, n = 91) and two external cohorts (Sites 3,4; n = 11, 10) using region-wise relative mean error (rME) of SUV in AC PET. RESULTS: Both models produced anatomically plausible sCT and AC PET with low errors when test data matched training distributions. FL fine-tuning improved robustness under distribution shift at Site 3, reducing errors across most regions, while maintaining comparable performance at Site 4 where protocols resembled the pretraining site. CONCLUSION: Multi-site FL is a feasible path to increase the generalizability of PET-based sCT while preserving data privacy. The proposed framework offers a practical template for training and deploying CT-less AC models across heterogeneous clinical environments. </p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2026-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13199553/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-026-00868-2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
BACKGROUND: Accurate PET quantification relies on attenuation correction (AC), commonly performed using a linear attenuation map derived from a CT acquisition. However, CT can introduce misregistration artifacts and adds radiation dose. Synthetic CT (sCT) from non-attenuation corrected (NAC) PET offers a CT-less alternative, but training robust models requires multi-site data that may be difficult to share under privacy regulations. We aim to enable PET-based sCT training across sites without exposing data. METHODS: We built a federated learning (FL) framework and trained two sCT generators–a paired conditional GAN and a CycleGAN. Models were pretrained on a single-site cohort (Site 1, n = 425) and fine-tuned via FL using additional data from Site 1 (n = 25) and a second site with different scanners and reconstruction parameters (Site 2, n = 25). Performance was assessed on an internal hold-out set (Site 1, n = 91) and two external cohorts (Sites 3,4; n = 11, 10) using region-wise relative mean error (rME) of SUV in AC PET. RESULTS: Both models produced anatomically plausible sCT and AC PET with low errors when test data matched training distributions. FL fine-tuning improved robustness under distribution shift at Site 3, reducing errors across most regions, while maintaining comparable performance at Site 4 where protocols resembled the pretraining site. CONCLUSION: Multi-site FL is a feasible path to increase the generalizability of PET-based sCT while preserving data privacy. The proposed framework offers a practical template for training and deploying CT-less AC models across heterogeneous clinical environments.
期刊介绍:
EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.