[Determination of atmospheric intermediate volatility organic compounds with thermal desorption-flow modulator comprehensive two-dimensional gas chromatography- time-of-flight mass spectrometry].

Rui Wang, Ying-Jie Li, Jia-Hua Wang, Chang-Wen Ma, Jia-Kui Jiang
{"title":"[Determination of atmospheric intermediate volatility organic compounds with thermal desorption-flow modulator comprehensive two-dimensional gas chromatography- time-of-flight mass spectrometry].","authors":"Rui Wang, Ying-Jie Li, Jia-Hua Wang, Chang-Wen Ma, Jia-Kui Jiang","doi":"10.3724/SP.J.1123.2025.07009","DOIUrl":null,"url":null,"abstract":"<p><p>Atmospheric intermediate volatile organic compounds (IVOCs) are complex mixtures. Due to the limited separation and identification capabilities of one-dimensional gas chromatography (<sup>1</sup>D-GC), a large portion of atmospheric IVOCs-which often elute as unresolved or complex peaks-are categorized as an unspeciated complex mixture (UCM). This constrains the accurate apportionment of atmospheric IVOCs. To address this problem, an alternative analytical method has been developed utilizing thermal desorption-flow modulation comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (TD-FM GC×GC-TOF MS) to measure atmospheric IVOCs. Analytical optimization focused on fill and flush time within a 3-second modulation period, with optimal values determined as 2 870 ms and 130 ms, respectively, to maximize separation efficiency and signal response. Compounds were separated on a ZB-5HT column (20 m×0.18 mm×0.18 μm) as the first dimension, with a BP-50 column (5 m×0.25 mm×0.20 μm) serving as the second dimension. Helium was employed as the carrier gas with column pressures maintained at 254.4 kPa (first dimension) and 202.1 kPa (second dimension). The following temperature program was used: 50 ℃ for 10 min, then increased to 300 ℃ at 10 ℃/min, with the final temperature held for 20 min. The MS was operated in electron impact (EI, 70 eV) ionization mode. Both the ion source and transfer line temperatures were set at 300 ℃. MS signals were recorded in full scan mode with a scan range of <i>m/z</i> 40 to <i>m/z</i> 800. During thermal desorption, the desorption temperature was set at 320 ℃, and the cold trap temperature was maintained at -10 ℃ to capture desorbed targets. The secondary desorption flow rate was set at 16 mL/min. Under these optimized conditions, the method demonstrated acceptable linearity, with correlation coefficients ranging from 0.922 3 to 0.998 4, for 69 selected targets spanning 1 to 20 ng/tube, with method detection limits (spiked at 1 ng/tube) between 0.010 7 and 0.410 1 ng/m<sup>3</sup>, with recoveries ranging from 80.4% to 136.0%. Relative standard deviation values among replicate samples (<i>n</i>=7) spiked at 1 ng/tube, 3 ng/tube, and 10 ng/tube levels were around 4.5%-33.9%, 3.2%-19.9% and 3.5%-18.6%, respectively. Application of the method to atmospheric IVOC samples collected from an urban site of Shanghai, revealed total IVOCs mass concentrations of 8.6-61.1 μg/m<sup>3</sup>. Of these, mass concentrations of 853 individual species identified by the present method comprised 96.2% of total IVOCs. Consequently,the newly developed method improved the identification rate for UCM. Importantly, the newly speciated aromatics, chlorinated IVOCs, and oxygenated IVOCs exhibited different emission sources distinct from those routinely monitored compounds. Therefore, this study established a reliable method for determining atmospheric IVOCs, offering strong data support for precise source apportionment of complex IVOCs in the atmosphere. Additionally, this method can be used to monitor IVOCs across various environmental metrics, thereby providing essential data to support the management and control of these compounds.</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"44 4","pages":"453-466"},"PeriodicalIF":0.0000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13077543/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2025.07009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Atmospheric intermediate volatile organic compounds (IVOCs) are complex mixtures. Due to the limited separation and identification capabilities of one-dimensional gas chromatography (1D-GC), a large portion of atmospheric IVOCs-which often elute as unresolved or complex peaks-are categorized as an unspeciated complex mixture (UCM). This constrains the accurate apportionment of atmospheric IVOCs. To address this problem, an alternative analytical method has been developed utilizing thermal desorption-flow modulation comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (TD-FM GC×GC-TOF MS) to measure atmospheric IVOCs. Analytical optimization focused on fill and flush time within a 3-second modulation period, with optimal values determined as 2 870 ms and 130 ms, respectively, to maximize separation efficiency and signal response. Compounds were separated on a ZB-5HT column (20 m×0.18 mm×0.18 μm) as the first dimension, with a BP-50 column (5 m×0.25 mm×0.20 μm) serving as the second dimension. Helium was employed as the carrier gas with column pressures maintained at 254.4 kPa (first dimension) and 202.1 kPa (second dimension). The following temperature program was used: 50 ℃ for 10 min, then increased to 300 ℃ at 10 ℃/min, with the final temperature held for 20 min. The MS was operated in electron impact (EI, 70 eV) ionization mode. Both the ion source and transfer line temperatures were set at 300 ℃. MS signals were recorded in full scan mode with a scan range of m/z 40 to m/z 800. During thermal desorption, the desorption temperature was set at 320 ℃, and the cold trap temperature was maintained at -10 ℃ to capture desorbed targets. The secondary desorption flow rate was set at 16 mL/min. Under these optimized conditions, the method demonstrated acceptable linearity, with correlation coefficients ranging from 0.922 3 to 0.998 4, for 69 selected targets spanning 1 to 20 ng/tube, with method detection limits (spiked at 1 ng/tube) between 0.010 7 and 0.410 1 ng/m3, with recoveries ranging from 80.4% to 136.0%. Relative standard deviation values among replicate samples (n=7) spiked at 1 ng/tube, 3 ng/tube, and 10 ng/tube levels were around 4.5%-33.9%, 3.2%-19.9% and 3.5%-18.6%, respectively. Application of the method to atmospheric IVOC samples collected from an urban site of Shanghai, revealed total IVOCs mass concentrations of 8.6-61.1 μg/m3. Of these, mass concentrations of 853 individual species identified by the present method comprised 96.2% of total IVOCs. Consequently,the newly developed method improved the identification rate for UCM. Importantly, the newly speciated aromatics, chlorinated IVOCs, and oxygenated IVOCs exhibited different emission sources distinct from those routinely monitored compounds. Therefore, this study established a reliable method for determining atmospheric IVOCs, offering strong data support for precise source apportionment of complex IVOCs in the atmosphere. Additionally, this method can be used to monitor IVOCs across various environmental metrics, thereby providing essential data to support the management and control of these compounds.

[热解吸-流动调制器综合二维气相色谱-飞行时间质谱法测定大气中挥发性有机化合物]。
大气中挥发性有机物是一种复杂的混合物。由于一维气相色谱(1D-GC)的分离和鉴定能力有限,大部分大气中挥发性有机化合物(通常被洗脱为未解析或复杂的峰)被归类为未指定的复杂混合物(UCM)。这限制了大气中挥发性有机化合物的准确分配。为了解决这一问题,研究人员开发了一种替代分析方法,利用热解吸-流动调制综合二维气相色谱法结合飞行时间质谱法(TD-FM GC×GC-TOF MS)来测量大气中挥发性有机化合物。分析优化的重点是3秒调制周期内的填充和冲洗时间,确定的最优值分别为2 870 ms和130 ms,以最大限度地提高分离效率和信号响应。以ZB-5HT柱(20 m×0.18 mm×0.18 μm)和BP-50柱(5 m×0.25 mm×0.20 μm)为第一维色谱柱分离化合物。载气为氦气,柱压分别为254.4 kPa(一维)和202.1 kPa(二维)。温度程序为:50℃保温10 min,然后以10℃/min的速度升温至300℃,保温20 min。质谱在电子冲击(EI, 70 eV)电离模式下运行。离子源和传输线温度均设置为300℃。MS信号以全扫描模式记录,扫描范围为m/z 40至m/z 800。在热解吸过程中,将解吸温度设定为320℃,冷阱温度保持在-10℃,以捕获解吸后的目标。二次解吸流速为16 mL/min。在优化条件下,69个测定指标的线性关系为0.922 ~ 0.998 4,相关系数为1 ~ 20 ng/管,检出限为0.0107 ~ 0.410 ng/m3,回收率为80.4% ~ 136.0%。在1 ng/管、3 ng/管和10 ng/管水平下,重复样本(n=7)的相对标准偏差值分别约为4.5%-33.9%、3.2%-19.9%和3.5%-18.6%。将该方法应用于上海某城市站点的大气IVOC样品,结果显示总IVOC质量浓度为8.6 ~ 61.1 μg/m3。其中,经本方法鉴定的853个物种的质量浓度占总IVOCs的96.2%。因此,新开发的方法提高了UCM的识别率。重要的是,新形成的芳香化合物、氯化IVOCs和氧化IVOCs的排放源与常规监测的化合物不同。因此,本研究建立了一种可靠的大气IVOCs测定方法,为大气中复杂IVOCs的精确源解析提供了强有力的数据支持。此外,该方法可用于监测各种环境指标中的IVOCs,从而为支持这些化合物的管理和控制提供必要的数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书