[Determination of eight ultraviolet absorbers in surface water and wastewater by ultra performance liquid chromatography-triple quadrupole mass spectrometry].

Hui-Jing Sun, Bei-Bei Zhang, Meng-Qiao Huang, Hui Wang, Guan-Jiu Hu, Hui-Min Chen
{"title":"[Determination of eight ultraviolet absorbers in surface water and wastewater by ultra performance liquid chromatography-triple quadrupole mass spectrometry].","authors":"Hui-Jing Sun, Bei-Bei Zhang, Meng-Qiao Huang, Hui Wang, Guan-Jiu Hu, Hui-Min Chen","doi":"10.3724/SP.J.1123.2025.08001","DOIUrl":null,"url":null,"abstract":"<p><p>Ultraviolet (UV) absorbers are a group of chemicals widely used in various industrial and consumer products, such as plastics, coatings, and personal care products, to protect against UV radiation. Among them, benzotriazole derivatives (e.g. UV-326, UV-327, UV-328, UV-329, and UV-P) are the most frequently employed. Owing to their widespread use and potential persistence in the environment, these compounds have been detected in various environmental matrices, including surface water, wastewater, sediment, and biota. Certain UV stabilizers have been reported to exhibit endocrine-disrupting properties and pose potential ecological risks. Therefore, developing sensitive and reliable analytical methods for monitoring these compounds in environmental samples is essential. To address the need for reliable detection methods, this study developed a robust method based on liquid-liquid extraction (LLE) coupled with ultra performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-MS/MS) for the simultaneous determination of eight UV absorbers in surface water and wastewater. Critical optimization of the pretreatment process focused on solvent selection and purification parameters. The finalized protocol involved extracting 100 mL water samples twice with dichloromethane. After nitrogen-assisted solvent evaporation, the residue was reconstituted in methanol and mixed with the internal standard solution. UPLC-MS/MS parameters were optimized to achieve optimal instrumental performance. The separation of the eight UVs was performed using a BEH C18 column (100 mm × 2.1 mm, 1.7 μm) with a gradient elution system consisting of 0.2% (mass fraction) formic acid aqueous solution and acetonitrile at a flow rate of 0.4 mL/min. The injection volume was 2 μL. Detection was performed in positive ion mode using multiple reaction monitoring (MRM), with an electrospray ionization voltage set at 5 500 V. Quantification was achieved via internal standard calibration to ensure precision and accuracy. The method demonstrated excellent linearity for all target compounds across their respective concentration ranges, with a correlation coefficient (<i>r</i>)>0.995. The method detection limits (MDLs) ranged from 1.3 ng/L to 2.8 ng/L, indicating high sensitivity. Recovery tests conducted at low, medium, and high spiking levels (20, 200, and 800 ng/L) yielded recoveries of 80.3%-117.8%, with relative standard deviations (RSDs) of 1.4%-10.5%, confirming the method's robustness across different sample matrices. Application of the method to 10 textile dyeing wastewater samples revealed the presence of four UV absorbers: UV-329, UV-326, UV-328, and UV-350. Notably, UV-329 showed the highest detection frequency and accounted for 85% of the total detected mass concentrations, ranging from 5.2 to 2 109 ng/L. Its prevalence suggests its widespread use in industrial processes and potential persistence in aquatic environments. In conclusion, the developed method is highly sensitive, accurate, and reliable for detecting UV absorbers in environmental water samples. Its successful application to surface water and wastewater analysis provides a valuable tool for monitoring these emerging contaminants, thereby supporting the assessment of their environmental and health risks. This study highlights the importance of continued monitoring and regulation of UV absorbers to mitigate their potential adverse effects on ecosystems and human health.</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"44 4","pages":"413-421"},"PeriodicalIF":0.0000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13077533/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2025.08001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Ultraviolet (UV) absorbers are a group of chemicals widely used in various industrial and consumer products, such as plastics, coatings, and personal care products, to protect against UV radiation. Among them, benzotriazole derivatives (e.g. UV-326, UV-327, UV-328, UV-329, and UV-P) are the most frequently employed. Owing to their widespread use and potential persistence in the environment, these compounds have been detected in various environmental matrices, including surface water, wastewater, sediment, and biota. Certain UV stabilizers have been reported to exhibit endocrine-disrupting properties and pose potential ecological risks. Therefore, developing sensitive and reliable analytical methods for monitoring these compounds in environmental samples is essential. To address the need for reliable detection methods, this study developed a robust method based on liquid-liquid extraction (LLE) coupled with ultra performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-MS/MS) for the simultaneous determination of eight UV absorbers in surface water and wastewater. Critical optimization of the pretreatment process focused on solvent selection and purification parameters. The finalized protocol involved extracting 100 mL water samples twice with dichloromethane. After nitrogen-assisted solvent evaporation, the residue was reconstituted in methanol and mixed with the internal standard solution. UPLC-MS/MS parameters were optimized to achieve optimal instrumental performance. The separation of the eight UVs was performed using a BEH C18 column (100 mm × 2.1 mm, 1.7 μm) with a gradient elution system consisting of 0.2% (mass fraction) formic acid aqueous solution and acetonitrile at a flow rate of 0.4 mL/min. The injection volume was 2 μL. Detection was performed in positive ion mode using multiple reaction monitoring (MRM), with an electrospray ionization voltage set at 5 500 V. Quantification was achieved via internal standard calibration to ensure precision and accuracy. The method demonstrated excellent linearity for all target compounds across their respective concentration ranges, with a correlation coefficient (r)>0.995. The method detection limits (MDLs) ranged from 1.3 ng/L to 2.8 ng/L, indicating high sensitivity. Recovery tests conducted at low, medium, and high spiking levels (20, 200, and 800 ng/L) yielded recoveries of 80.3%-117.8%, with relative standard deviations (RSDs) of 1.4%-10.5%, confirming the method's robustness across different sample matrices. Application of the method to 10 textile dyeing wastewater samples revealed the presence of four UV absorbers: UV-329, UV-326, UV-328, and UV-350. Notably, UV-329 showed the highest detection frequency and accounted for 85% of the total detected mass concentrations, ranging from 5.2 to 2 109 ng/L. Its prevalence suggests its widespread use in industrial processes and potential persistence in aquatic environments. In conclusion, the developed method is highly sensitive, accurate, and reliable for detecting UV absorbers in environmental water samples. Its successful application to surface water and wastewater analysis provides a valuable tool for monitoring these emerging contaminants, thereby supporting the assessment of their environmental and health risks. This study highlights the importance of continued monitoring and regulation of UV absorbers to mitigate their potential adverse effects on ecosystems and human health.

超高效液相色谱-三重四极杆质谱法测定地表水和废水中8种紫外线吸收剂
紫外线吸收剂是一组化学物质,广泛用于各种工业和消费品,如塑料、涂料和个人护理产品,以防止紫外线辐射。其中,最常用的是苯并三唑衍生物(如UV-326、UV-327、UV-328、UV-329和UV-P)。由于它们的广泛使用和在环境中的潜在持久性,这些化合物已在各种环境基质中被检测到,包括地表水、废水、沉积物和生物群。据报道,某些紫外线稳定剂表现出干扰内分泌的特性,并构成潜在的生态风险。因此,开发敏感可靠的分析方法来监测环境样品中的这些化合物是至关重要的。为了满足对可靠检测方法的需求,本研究建立了一种基于液液萃取(LLE) -超高效液相色谱-三重四极杆质谱(UPLC-MS/MS)同时测定地面水和废水中8种紫外线吸收剂的稳健方法。预处理过程的关键优化主要集中在溶剂选择和纯化参数上。最终方案涉及用二氯甲烷提取100毫升水样两次。氮气辅助溶剂蒸发后,将残留物在甲醇中重组,并与内标溶液混合。优化UPLC-MS/MS参数以获得最佳仪器性能。采用BEH C18色谱柱(100 mm × 2.1 mm, 1.7 μm),梯度洗脱体系为0.2%(质量分数)甲酸水溶液和乙腈,流速为0.4 mL/min。注射量为2 μL。采用多反应监测(MRM)在正离子模式下进行检测,电喷雾电离电压设置为5 500 V。通过内标校准实现定量,以确保精密度和准确度。该方法在各浓度范围内均具有良好的线性关系,相关系数(r)为>0.995。方法检出限(MDLs)为1.3 ~ 2.8 ng/L,灵敏度高。在低、中、高浓度(20、200、800 ng/L)条件下进行的回收率测试,回收率为80.3% ~ 117.8%,相对标准偏差(rsd)为1.4% ~ 10.5%,证实了该方法在不同样品基质中的鲁棒性。将该方法应用于10个纺织印染废水样品,发现存在4种紫外线吸收剂:UV-329、UV-326、UV-328和UV-350。其中,UV-329的检测频率最高,占总检测质量浓度的85%,范围为5.2 ~ 2 109 ng/L。它的普遍存在表明它在工业过程中的广泛使用和在水生环境中的潜在持久性。该方法对环境水样中紫外线吸收剂的检测具有较高的灵敏度、准确性和可靠性。它成功地应用于地表水和废水分析,为监测这些新出现的污染物提供了宝贵的工具,从而支持评估其环境和健康风险。这项研究强调了持续监测和调节紫外线吸收剂以减轻其对生态系统和人类健康的潜在不利影响的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书