{"title":"Impact of Resisted Inspiratory Training Using the NU SpiroBreath Device on Diaphragmatic Muscle Activity: A Randomized Crossover Trial in Healthy Adults.","authors":"Prayuth Poowaruttanawiwit, Narongrit Nuchnueng, Jetsada Maprom, Peeranut Juiwong, Weerapong Chidnok","doi":"10.1002/pri.70210","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>The NU SpiroBreath device was developed as a novel respiratory training tool to support post-operative recovery in cardiac and thoracic surgery patients. While previous studies have demonstrated its safety and user acceptability, its effect on diaphragmatic muscle activation during resisted inspiratory maneuvers has not been fully characterized. The aim of this study was to assess diaphragmatic muscle activity during deep inspiratory breathing with and without resistance using the NU SpiroBreath device in healthy adults.</p><p><strong>Methods: </strong>Twelve healthy male participants (aged 20-30 years) participated in a single-blind, randomized, two-period crossover trial. Participants performed deep inspiratory breathing maneuvers using the NU SpiroBreath device under two conditions: 0 cm H<sub>2</sub>O (sham) and 10 cm H<sub>2</sub>O (resistance), with a 2-week washout period between sessions. Each session included a 5-min baseline control followed by three sets of 10 deep inspiratory efforts (DI1-DI3), separated by 1-min rest intervals. Diaphragm muscle activity was assessed using high-resolution surface electromyography (sEMG) recorded at 4000 Hz, filtered (20-500 Hz), and analyzed using root mean square (RMS) values.</p><p><strong>Results: </strong>Significant increases in diaphragmatic muscle activity were observed from baseline at both resistance levels (p < 0.05). At 0 cm H<sub>2</sub>O, activity increased during DI1 and DI2; at 10 cm H<sub>2</sub>O, increased activation was sustained across DI1, DI2, and DI3. However, no statistically significant differences were found between the 0 cm H<sub>2</sub>O and 10 cm H<sub>2</sub>O conditions (p > 0.05), suggesting that even minimal resistance elicits robust diaphragmatic recruitment in untrained healthy individuals.</p><p><strong>Discussion: </strong>Inspiratory training using the NU SpiroBreath device significantly enhances diaphragmatic muscle activation regardless of resistance level. These findings support its utility as a safe, low-burden respiratory training tool.</p>","PeriodicalId":47243,"journal":{"name":"Physiotherapy Research International","volume":"31 2","pages":"e70210"},"PeriodicalIF":1.7000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiotherapy Research International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/pri.70210","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose: The NU SpiroBreath device was developed as a novel respiratory training tool to support post-operative recovery in cardiac and thoracic surgery patients. While previous studies have demonstrated its safety and user acceptability, its effect on diaphragmatic muscle activation during resisted inspiratory maneuvers has not been fully characterized. The aim of this study was to assess diaphragmatic muscle activity during deep inspiratory breathing with and without resistance using the NU SpiroBreath device in healthy adults.

Methods: Twelve healthy male participants (aged 20-30 years) participated in a single-blind, randomized, two-period crossover trial. Participants performed deep inspiratory breathing maneuvers using the NU SpiroBreath device under two conditions: 0 cm H2O (sham) and 10 cm H2O (resistance), with a 2-week washout period between sessions. Each session included a 5-min baseline control followed by three sets of 10 deep inspiratory efforts (DI1-DI3), separated by 1-min rest intervals. Diaphragm muscle activity was assessed using high-resolution surface electromyography (sEMG) recorded at 4000 Hz, filtered (20-500 Hz), and analyzed using root mean square (RMS) values.

Results: Significant increases in diaphragmatic muscle activity were observed from baseline at both resistance levels (p < 0.05). At 0 cm H2O, activity increased during DI1 and DI2; at 10 cm H2O, increased activation was sustained across DI1, DI2, and DI3. However, no statistically significant differences were found between the 0 cm H2O and 10 cm H2O conditions (p > 0.05), suggesting that even minimal resistance elicits robust diaphragmatic recruitment in untrained healthy individuals.

Discussion: Inspiratory training using the NU SpiroBreath device significantly enhances diaphragmatic muscle activation regardless of resistance level. These findings support its utility as a safe, low-burden respiratory training tool.

使用NU SpiroBreath装置进行抗吸气训练对膈肌活动的影响:一项健康成人随机交叉试验
背景和目的:NU SpiroBreath装置是一种新型的呼吸训练工具,用于心脏和胸外科手术患者的术后恢复。虽然以前的研究已经证明了它的安全性和用户可接受性,但它对阻力吸气动作中膈肌激活的影响尚未完全表征。本研究的目的是使用NU SpiroBreath装置评估健康成人在有和无阻力深吸气时的膈肌活动。方法:12名健康男性(20-30岁)参加了一项单盲、随机、两期交叉试验。参与者使用NU SpiroBreath装置在两种条件下进行深吸气操作:0厘米水(假)和10厘米水(阻力),两次训练之间有两周的洗脱期。每个疗程包括5分钟的基线控制,然后是三组10次的深度吸气(DI1-DI3),中间间隔1分钟的休息时间。使用高分辨率表面肌电图(sEMG)评估膈肌活动,在4000 Hz下记录,过滤(20-500 Hz),并使用均方根(RMS)值进行分析。结果:在两种阻力水平下,膈肌活动从基线显著增加(p 2O, DI1和DI2期间活动增加;在10 cm H2O时,DI1, DI2和DI3之间的活动持续增加。然而,在0 cm H2O和10 cm H2O条件下,没有发现统计学上的显著差异(p > 0.05),这表明即使最小的阻力也能在未经训练的健康个体中引起强劲的膈肌补充。讨论:使用NU SpiroBreath装置进行吸气训练,无论阻力水平如何,都能显著增强膈肌的激活。这些发现支持它作为一种安全、低负担的呼吸训练工具的效用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
5.90%
发文量
53
期刊介绍: Physiotherapy Research International is an international peer reviewed journal dedicated to the exchange of knowledge that is directly relevant to specialist areas of physiotherapy theory, practice, and research. Our aim is to promote a high level of scholarship and build on the current evidence base to inform the advancement of the physiotherapy profession. We publish original research on a wide range of topics e.g. Primary research testing new physiotherapy treatments; methodological research; measurement and outcome research and qualitative research of interest to researchers, clinicians and educators. Further, we aim to publish high quality papers that represent the range of cultures and settings where physiotherapy services are delivered. We attract a wide readership from physiotherapists and others working in diverse clinical and academic settings. We aim to promote an international debate amongst the profession about current best evidence based practice. Papers are directed primarily towards the physiotherapy profession, but can be relevant to a wide range of professional groups. The growth of interdisciplinary research is also key to our aims and scope, and we encourage relevant submissions from other professional groups. The journal actively encourages submissions which utilise a breadth of different methodologies and research designs to facilitate addressing key questions related to the physiotherapy practice. PRI seeks to encourage good quality topical debates on a range of relevant issues and promote critical reflection on decision making and implementation of physiotherapy interventions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书