Improving Intraoperative Compliance With Critical View of the Myopectineal Orifice Criteria Using the V-M Pathway During Laparoscopic Inguinal Hernia Repair.
Kryspin Mitura, Laura Kacprzak, Marta Wojcik, Lidia Mitura, Michal Romanczuk, Bernard Mitura, Orest Lerchuk, Volodymyr Khomyak, Orest Chemerys, Piotr Niecikowski
{"title":"Improving Intraoperative Compliance With Critical View of the Myopectineal Orifice Criteria Using the V-M Pathway During Laparoscopic Inguinal Hernia Repair.","authors":"Kryspin Mitura, Laura Kacprzak, Marta Wojcik, Lidia Mitura, Michal Romanczuk, Bernard Mitura, Orest Lerchuk, Volodymyr Khomyak, Orest Chemerys, Piotr Niecikowski","doi":"10.3389/jaws.2026.16223","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The CVMPO criteria were developed to standardize critical quality steps during laparoscopic inguinal hernia repair. However, consistent intraoperative compliance remains challenging, particularly during prolonged or technically difficult procedures, or under cognitive fatigue. Checklist-based approaches may be difficult to recall and apply in real time.</p><p><strong>Methods: </strong>A prospective observational study included 211 consecutive laparoscopic inguinal hernia repairs performed using a standardized technique. An original spatial cognitive framework, the V-M Pathway, mapping CVMPO criteria onto the laparoscopic view of the inguinal region, was applied as a deliberate intraoperative pause before mesh placement. Time required to verbally recall all nine CVMPO criteria was measured intraoperatively. All procedures were routinely recorded in full from the beginning to the end of the operation. Surgeon-identified corrective actions prompted by CVMPO recall were documented during the procedure. The time required to implement corrective actions was determined postoperatively based on independent review of the complete operative video recordings. All procedures underwent <i>post hoc</i> video verification to confirm objective adherence to the CVMPO criteria.</p><p><strong>Results: </strong>Complete recall of all nine CVMPO criteria using the V-M Pathway was achieved in all procedures, with a median recall time of 58 s (IQR 52-64). Intraoperative recall prompted corrective actions in 20.4% of cases. Among procedures requiring corrective actions, the median time required to complete all corrections was 46 s (IQR 38-81). Independent video review confirmed complete adherence to all CVMPO criteria in 97.2% of procedures. Mesh placement was performed only after CVMPO confirmation in all cases.</p><p><strong>Conclusion: </strong>The V-M Pathway supported rapid intraoperative recall of CVMPO criteria, prompted timely corrective actions, and was associated with high video-verified adherence to predefined quality criteria. Importantly, the additional time required for recall and corrective actions represented only a small fraction of total operative time, suggesting that integration of the pathway is feasible without major workflow disruption. This simple spatial cognitive aid may support intraoperative verification of quality criteria during laparoscopic inguinal hernia repair without disrupting operative workflow.</p>","PeriodicalId":516856,"journal":{"name":"Journal of abdominal wall surgery : JAWS","volume":"5 ","pages":"16223"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13056872/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of abdominal wall surgery : JAWS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/jaws.2026.16223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The CVMPO criteria were developed to standardize critical quality steps during laparoscopic inguinal hernia repair. However, consistent intraoperative compliance remains challenging, particularly during prolonged or technically difficult procedures, or under cognitive fatigue. Checklist-based approaches may be difficult to recall and apply in real time.
Methods: A prospective observational study included 211 consecutive laparoscopic inguinal hernia repairs performed using a standardized technique. An original spatial cognitive framework, the V-M Pathway, mapping CVMPO criteria onto the laparoscopic view of the inguinal region, was applied as a deliberate intraoperative pause before mesh placement. Time required to verbally recall all nine CVMPO criteria was measured intraoperatively. All procedures were routinely recorded in full from the beginning to the end of the operation. Surgeon-identified corrective actions prompted by CVMPO recall were documented during the procedure. The time required to implement corrective actions was determined postoperatively based on independent review of the complete operative video recordings. All procedures underwent post hoc video verification to confirm objective adherence to the CVMPO criteria.
Results: Complete recall of all nine CVMPO criteria using the V-M Pathway was achieved in all procedures, with a median recall time of 58 s (IQR 52-64). Intraoperative recall prompted corrective actions in 20.4% of cases. Among procedures requiring corrective actions, the median time required to complete all corrections was 46 s (IQR 38-81). Independent video review confirmed complete adherence to all CVMPO criteria in 97.2% of procedures. Mesh placement was performed only after CVMPO confirmation in all cases.
Conclusion: The V-M Pathway supported rapid intraoperative recall of CVMPO criteria, prompted timely corrective actions, and was associated with high video-verified adherence to predefined quality criteria. Importantly, the additional time required for recall and corrective actions represented only a small fraction of total operative time, suggesting that integration of the pathway is feasible without major workflow disruption. This simple spatial cognitive aid may support intraoperative verification of quality criteria during laparoscopic inguinal hernia repair without disrupting operative workflow.
背景:CVMPO标准的制定是为了规范腹腔镜腹股沟疝修补的关键质量步骤。然而,持续的术中依从性仍然具有挑战性,特别是在长时间或技术困难的手术中,或者在认知疲劳的情况下。基于检查表的方法可能难以回忆和实时应用。方法:一项前瞻性观察研究包括211例使用标准化技术进行的连续腹腔镜腹股沟疝修补术。一个原始的空间认知框架,V-M路径,将CVMPO标准映射到腹股沟区域的腹腔镜视图,被应用于补片放置前的故意术中暂停。术中测量口头回忆所有9项CVMPO标准所需的时间。从手术开始到结束,所有的程序都被完整地记录下来。在手术过程中记录了由CVMPO召回引起的外科医生确定的纠正措施。术后根据对完整手术录像的独立审查确定实施纠正措施所需的时间。所有程序都经过事后视频核查,以确认客观遵守CVMPO标准。结果:在所有程序中,使用V-M途径的所有九个CVMPO标准都实现了完全召回,中位召回时间为58秒(IQR 52-64)。术中回忆促使纠正措施的发生率为20.4%。在需要纠正措施的程序中,完成所有纠正所需的中位时间为46 s (IQR 38-81)。独立视频审查证实97.2%的程序完全符合所有CVMPO标准。所有病例均在CVMPO确认后进行补片。结论:V-M通路支持术中快速回忆CVMPO标准,提示及时纠正措施,并与高视频验证的预先质量标准的依从性相关。重要的是,召回和纠正措施所需的额外时间仅占总操作时间的一小部分,这表明在不中断主要工作流程的情况下,整合该途径是可行的。这种简单的空间认知辅助可以支持腹腔镜腹股沟疝修补术中质量标准的术中验证,而不会中断手术工作流程。