Methods of nerve mapping to prevent iatrogenic nerve injuries during ankle arthroscopy: scoping review.

IF 4.6 2区 医学 Q1 ORTHOPEDICS
Philippe Beaudet, Kinga Michalewska, Floris van Rooij, Mo Saffarini, Alexis Nogier
{"title":"Methods of nerve mapping to prevent iatrogenic nerve injuries during ankle arthroscopy: scoping review.","authors":"Philippe Beaudet, Kinga Michalewska, Floris van Rooij, Mo Saffarini, Alexis Nogier","doi":"10.1530/EOR-2024-0201","DOIUrl":null,"url":null,"abstract":"<p><p>To synthesise the literature on pre- and intra-operative nerve mapping used to prevent iatrogenic nerve injuries during ankle arthroscopy. This scoping review followed the PRISMA Extension for Scoping Reviews (PRISMA-ScR) guidelines. A systematic search was conducted using MEDLINE and Embase on 24 July 2024. Findings extracted from eligible studies were tabulated and synthesised. The search identified 270 articles, of which 9 met inclusion/exclusion criteria and were included in the review. Two studies described a mapping technique without reporting any outcomes, and three studies evaluated mapping techniques on cadavers and four on live patients. Four studies reported on visualisation and/or palpation, one study on arthroscopic transillumination, three on ultrasound and two on near-infrared light (NIR). There were only two comparative studies that showed that pre-operative ultrasound mapping places the nerves at safer distances from the portals and that ultrasound is more effective in the identification of the superficial peroneal nerve (SPN) than visualisation and/or palpation. Visualisation and/or palpation of the SPN is the most effective in ankle maximal plantar flexion and inversion and reduces the risk of nerve injury. There was no saphenous nerve injury with percutaneous screw insertion while using NIR. A reduction in nerve injuries during ankle arthroscopy might be achievable by using pre- or intra-operative nerve mapping with visualisation and/or palpation, ultrasound or (for nerves accompanied by the veins) NIR. The limited evidence suggests that pre-operative ultrasound might be potentially the most effective mapping method, but more comparative and prospective studies are needed to fully confirm these findings.</p>","PeriodicalId":48598,"journal":{"name":"Efort Open Reviews","volume":"11 4","pages":"243-249"},"PeriodicalIF":4.6000,"publicationDate":"2026-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13087881/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Efort Open Reviews","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1530/EOR-2024-0201","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

To synthesise the literature on pre- and intra-operative nerve mapping used to prevent iatrogenic nerve injuries during ankle arthroscopy. This scoping review followed the PRISMA Extension for Scoping Reviews (PRISMA-ScR) guidelines. A systematic search was conducted using MEDLINE and Embase on 24 July 2024. Findings extracted from eligible studies were tabulated and synthesised. The search identified 270 articles, of which 9 met inclusion/exclusion criteria and were included in the review. Two studies described a mapping technique without reporting any outcomes, and three studies evaluated mapping techniques on cadavers and four on live patients. Four studies reported on visualisation and/or palpation, one study on arthroscopic transillumination, three on ultrasound and two on near-infrared light (NIR). There were only two comparative studies that showed that pre-operative ultrasound mapping places the nerves at safer distances from the portals and that ultrasound is more effective in the identification of the superficial peroneal nerve (SPN) than visualisation and/or palpation. Visualisation and/or palpation of the SPN is the most effective in ankle maximal plantar flexion and inversion and reduces the risk of nerve injury. There was no saphenous nerve injury with percutaneous screw insertion while using NIR. A reduction in nerve injuries during ankle arthroscopy might be achievable by using pre- or intra-operative nerve mapping with visualisation and/or palpation, ultrasound or (for nerves accompanied by the veins) NIR. The limited evidence suggests that pre-operative ultrasound might be potentially the most effective mapping method, but more comparative and prospective studies are needed to fully confirm these findings.

踝关节镜检查中预防医源性神经损伤的神经定位方法:镜检综述。
综合有关术前和术中神经定位预防踝关节镜手术中医源性神经损伤的文献。本次范围审查遵循PRISMA范围审查扩展(PRISMA- scr)指南。2024年7月24日使用MEDLINE和Embase进行系统检索。从符合条件的研究中提取的结果被制成表格并加以综合。检索确定了270篇文章,其中9篇符合纳入/排除标准,被纳入本综述。两项研究描述了一种测绘技术,但没有报告任何结果,三项研究评估了对尸体的测绘技术,四项研究评估了对活体患者的测绘技术。四项研究报告了视觉和/或触诊,一项研究报告了关节镜透视,三项研究报告了超声,两项研究报告了近红外光(NIR)。只有两项比较研究表明,术前超声定位将神经置于离门静脉较安全的距离,并且超声在识别腓浅神经(SPN)方面比目测和/或触诊更有效。目视和/或触诊SPN是踝关节最大足底屈曲和内翻最有效的方法,可降低神经损伤的风险。经皮螺钉置入无隐神经损伤。通过术前或术中使用视觉和/或触诊、超声或(伴随静脉的)近红外(NIR)神经测绘,可以减少踝关节镜检查期间的神经损伤。有限的证据表明术前超声可能是潜在的最有效的定位方法,但需要更多的比较和前瞻性研究来充分证实这些发现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Efort Open Reviews
Efort Open Reviews Medicine-Orthopedics and Sports Medicine
CiteScore
6.60
自引率
2.90%
发文量
101
审稿时长
13 weeks
期刊介绍: EFORT Open Reviews publishes high-quality instructional review articles across the whole field of orthopaedics and traumatology. Commissioned, peer-reviewed articles from international experts summarize current knowledge and practice in orthopaedics, with the aim of providing systematic coverage of the field. All articles undergo rigorous scientific editing to ensure the highest standards of accuracy and clarity. This continuously published online journal is fully open access and will provide integrated CME. It is an authoritative resource for educating trainees and supports practising orthopaedic surgeons in keeping informed about the latest clinical and scientific advances. One print issue containing a selection of papers from the journal will be published each year to coincide with the EFORT Annual Congress. EFORT Open Reviews is the official journal of the European Federation of National Associations of Orthopaedics and Traumatology (EFORT) and is published in partnership with The British Editorial Society of Bone & Joint Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书