{"title":"Genetically significant diagnostic X-ray dose in The Netherlands.","authors":"L B Beentjes, J H Duijsings, C Zuur","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An updated genetically significant X-ray dose (GSD) for The Netherlands is presented. A comparison is made between sets of gonadal doses from The Netherlands, France, Sweden and the USA. A 1980 (Dutch) frequency distribution of diagnostic X-ray examinations served to calculate the GSD with these four sets of doses yielding 0.23, 0.10, 0.20 and 0.09 mSv, respectively. A reduction of the Dutch GSD appears possible.</p>","PeriodicalId":77706,"journal":{"name":"Diagnostic imaging in clinical medicine","volume":"55 6","pages":"360-3"},"PeriodicalIF":0.0000,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic imaging in clinical medicine","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
An updated genetically significant X-ray dose (GSD) for The Netherlands is presented. A comparison is made between sets of gonadal doses from The Netherlands, France, Sweden and the USA. A 1980 (Dutch) frequency distribution of diagnostic X-ray examinations served to calculate the GSD with these four sets of doses yielding 0.23, 0.10, 0.20 and 0.09 mSv, respectively. A reduction of the Dutch GSD appears possible.