{"title":"Assessing Aortic Stenosis Severity in Dynamic Left Ventricular Outflow Obstruction Using Echo Doppler","authors":"Jennis Marthe MD, Timmermans Frank MD, PhD","doi":"10.1016/j.case.2025.10.005","DOIUrl":null,"url":null,"abstract":"<div><ul><li><span>•</span><span><div>Use the MB equation in the context of tandem stenosis.</div></span></li><li><span>•</span><span><div>A multimodality approach is preferred in this complex hemodynamic situation.</div></span></li><li><span>•</span><span><div>HPRF Doppler with time-aligned velocities can assess AS severity in tandem stenosis.</div></span></li><li><span>•</span><span><div>The use of HPRF reduces aliasing at the cost of introducing some range ambiguity.</div></span></li><li><span>•</span><span><div>Continuity equation may be considered using the volumetric LVSV.</div></span></li></ul></div><div><span><figure><span><img><ol><li><span><span>Download: <span>Download high-res image (146KB)</span></span></span></li><li><span><span>Download: <span>Download full-size image</span></span></span></li></ol></span></figure></span></div>","PeriodicalId":72532,"journal":{"name":"CASE (Philadelphia, Pa.)","volume":"10 3","pages":"Pages 99-103"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CASE (Philadelphia, Pa.)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468644125002580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
•
Use the MB equation in the context of tandem stenosis.
•
A multimodality approach is preferred in this complex hemodynamic situation.
•
HPRF Doppler with time-aligned velocities can assess AS severity in tandem stenosis.
•
The use of HPRF reduces aliasing at the cost of introducing some range ambiguity.
•
Continuity equation may be considered using the volumetric LVSV.