Assessing Aortic Stenosis Severity in Dynamic Left Ventricular Outflow Obstruction Using Echo Doppler

CASE (Philadelphia, Pa.) Pub Date : 2026-03-01 Epub Date: 2025-12-01 DOI:10.1016/j.case.2025.10.005
Jennis Marthe MD, Timmermans Frank MD, PhD
{"title":"Assessing Aortic Stenosis Severity in Dynamic Left Ventricular Outflow Obstruction Using Echo Doppler","authors":"Jennis Marthe MD,&nbsp;Timmermans Frank MD, PhD","doi":"10.1016/j.case.2025.10.005","DOIUrl":null,"url":null,"abstract":"<div><ul><li><span>•</span><span><div>Use the MB equation in the context of tandem stenosis.</div></span></li><li><span>•</span><span><div>A multimodality approach is preferred in this complex hemodynamic situation.</div></span></li><li><span>•</span><span><div>HPRF Doppler with time-aligned velocities can assess AS severity in tandem stenosis.</div></span></li><li><span>•</span><span><div>The use of HPRF reduces aliasing at the cost of introducing some range ambiguity.</div></span></li><li><span>•</span><span><div>Continuity equation may be considered using the volumetric LVSV.</div></span></li></ul></div><div><span><figure><span><img><ol><li><span><span>Download: <span>Download high-res image (146KB)</span></span></span></li><li><span><span>Download: <span>Download full-size image</span></span></span></li></ol></span></figure></span></div>","PeriodicalId":72532,"journal":{"name":"CASE (Philadelphia, Pa.)","volume":"10 3","pages":"Pages 99-103"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CASE (Philadelphia, Pa.)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468644125002580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

  • •
    Use the MB equation in the context of tandem stenosis.
  • •
    A multimodality approach is preferred in this complex hemodynamic situation.
  • •
    HPRF Doppler with time-aligned velocities can assess AS severity in tandem stenosis.
  • •
    The use of HPRF reduces aliasing at the cost of introducing some range ambiguity.
  • •
    Continuity equation may be considered using the volumetric LVSV.
  1. Download: Download high-res image (146KB)
  2. Download: Download full-size image

Abstract Image

超声多普勒评价动态左心室流出梗阻主动脉瓣狭窄严重程度。
•在串联狭窄的情况下使用MB方程。•在这种复杂的血流动力学情况下,首选多模式方法。HPRF多普勒随时间排列的速度可以评估串联狭窄的AS严重程度。HPRF的使用以引入一些距离模糊为代价减少了混叠。•连续性方程可以考虑使用体积LVSV。下载:下载高分辨率图片(146KB)下载:下载全尺寸图片
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CASE (Philadelphia, Pa.)
CASE (Philadelphia, Pa.) Radiology and Imaging, Cardiology and Cardiovascular Medicine, Radiography
自引率
0.00%
发文量
0
审稿时长
53 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书