High-velocity gunshot-related humeral fractures managed with circular external fixation in a resource-limited setting, Samburu County, Kenya: Surgical technique highlights from a case series.

Daniele Sciuto, Kiran J Agarwal-Harding, Luigi Paolo Spreafico
{"title":"High-velocity gunshot-related humeral fractures managed with circular external fixation in a resource-limited setting, Samburu County, Kenya: Surgical technique highlights from a case series.","authors":"Daniele Sciuto, Kiran J Agarwal-Harding, Luigi Paolo Spreafico","doi":"10.1097/OI9.0000000000000476","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>High-velocity gunshot-related humeral fractures are complex injuries often associated with a high rate of nonunion, infection, and poor functional outcome. In low- and middle-income countries these injuries are further complicated by delayed presentation and implant unavailability. Staged management with spanning external fixation followed by internal fixation with intramedullary nail or plate has been well described in the literature; however, the use of a circular frame as a definitive treatment has been very seldom mentioned.</p><p><strong>Materials and methods: </strong>Six high-velocity gunshot-related humeral fractures cases were treated with a single stack half ring circular external fixator as a definitive surgery performed by a single surgeon. Aspects related to surgical technique, fracture reduction, infection prevention, and restoration of upper limb function using circular frame external fixator are described.</p><p><strong>Results: </strong>Fracture union was achieved with circular fixation alone in 5 of the 6 patients. One patient developed a nonunion and required a second operation with a lateral compression plate combined with iliac crest autograft. The median circular fixator time was 16 weeks, and the median elbow range of motion was from 0° to 130° of flexion. The median shoulder range of motion was from 0° to 170° of overhead extension. The median Quick-DASH score was 4.5. No patients developed pin site infections.</p><p><strong>Conclusion: </strong>Single-stage definitive treatment with a circular external fixator may be a valid option, not only for surgeons working in resource-constrained environments, for high-velocity gunshot fractures of the humerus. Patients' cultural acceptance and maintenance of the external device far exceeded our expectations.</p>","PeriodicalId":74381,"journal":{"name":"OTA international : the open access journal of orthopaedic trauma","volume":"9 2","pages":"e476"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13004204/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"OTA international : the open access journal of orthopaedic trauma","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/OI9.0000000000000476","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: High-velocity gunshot-related humeral fractures are complex injuries often associated with a high rate of nonunion, infection, and poor functional outcome. In low- and middle-income countries these injuries are further complicated by delayed presentation and implant unavailability. Staged management with spanning external fixation followed by internal fixation with intramedullary nail or plate has been well described in the literature; however, the use of a circular frame as a definitive treatment has been very seldom mentioned.

Materials and methods: Six high-velocity gunshot-related humeral fractures cases were treated with a single stack half ring circular external fixator as a definitive surgery performed by a single surgeon. Aspects related to surgical technique, fracture reduction, infection prevention, and restoration of upper limb function using circular frame external fixator are described.

Results: Fracture union was achieved with circular fixation alone in 5 of the 6 patients. One patient developed a nonunion and required a second operation with a lateral compression plate combined with iliac crest autograft. The median circular fixator time was 16 weeks, and the median elbow range of motion was from 0° to 130° of flexion. The median shoulder range of motion was from 0° to 170° of overhead extension. The median Quick-DASH score was 4.5. No patients developed pin site infections.

Conclusion: Single-stage definitive treatment with a circular external fixator may be a valid option, not only for surgeons working in resource-constrained environments, for high-velocity gunshot fractures of the humerus. Patients' cultural acceptance and maintenance of the external device far exceeded our expectations.

肯尼亚Samburu县,在资源有限的情况下,采用环形外固定支架治疗高速枪击相关肱骨骨折:来自一系列病例的外科技术要点。
导言:高速枪击相关肱骨骨折是一种复杂的损伤,通常伴有高发生率的不愈合、感染和不良的功能预后。在低收入和中等收入国家,这些损伤因延迟呈现和无法获得植入物而进一步复杂化。在文献中有很好的描述了分阶段的治疗方法,即跨越外固定,然后用髓内钉或钢板内固定;然而,使用圆形框架作为明确的治疗已经很少被提及。材料和方法:6例高速枪击相关肱骨骨折病例采用单堆半环形外固定架作为最终手术,由一名外科医生完成。本文描述了使用圆形框架外固定架进行手术技术、骨折复位、感染预防和上肢功能恢复的相关方面。结果:6例患者中有5例仅采用环形内固定实现骨折愈合。一名患者出现骨不连,需要进行第二次手术,采用外侧加压钢板联合自体髂骨移植。中位圆形固定器时间为16周,肘关节中位活动范围为屈曲0°至130°。中位肩关节活动范围为头顶伸展0°至170°。Quick-DASH评分中位数为4.5分。无患者发生针部感染。结论:环形外固定架单阶段确定治疗可能是一种有效的选择,不仅适用于在资源受限环境下工作的外科医生,也适用于肱骨高速枪伤骨折。患者对体外装置的文化接受度和维护程度远远超出了我们的预期。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
4 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书