A Simplified Method for Determining the Safe Zone in Proximal Radial Plate Fixation

IF 2.4 2区 医学 Q2 ORTHOPEDICS
Journal of Hand Surgery-American Volume Pub Date : 2026-09-01 Epub Date: 2026-03-21 DOI:10.1016/j.jhsa.2026.02.003
Piyabuth Kittithamvongs MD, MSc, Prapasiri Chareonsri MD, Sopinun Siripoonyothai MD, Navapong Anantavorasakul MD, Kanchai Malungpaishrope MD, Chairoj Uerpairojkit MD
{"title":"A Simplified Method for Determining the Safe Zone in Proximal Radial Plate Fixation","authors":"Piyabuth Kittithamvongs MD, MSc,&nbsp;Prapasiri Chareonsri MD,&nbsp;Sopinun Siripoonyothai MD,&nbsp;Navapong Anantavorasakul MD,&nbsp;Kanchai Malungpaishrope MD,&nbsp;Chairoj Uerpairojkit MD","doi":"10.1016/j.jhsa.2026.02.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>The radial head and neck feature a unique anatomical structure, whereby the application of a plate in certain areas can lead to impingement, subsequently restricting the forearm rotation. Various techniques have been suggested to identify the appropriate region for plate fixation. We propose an alternative method to locate a safe zone for plate placement and conduct a comparative analysis with previously established methods.</div></div><div><h3>Methods</h3><div>The study included 30 embalmed cadavers. All specimens demonstrated a full passive range of forearm rotation. A plate was positioned on the most anterior aspect of the radial head/neck with the forearm in full pronation (anteroposterior position) and on the most posterior aspect with the forearm in full supination (P-S position). We assessed the range of motion to identify proximal radioulnar joint impingement and compared the plate's positioning to the safe zone described by Caputo and Smith.</div></div><div><h3>Results</h3><div>All specimens maintained a full passive range of motion following plate fixation in all positions. The plate placement fell within the boundaries of Caputo's radial styloid direction and Smith's Lister's tubercle direction. The average plating zone measured 94°.</div></div><div><h3>Conclusions</h3><div>Positioning the plate at the most anterior aspect during forearm pronation or at the most posterior aspect during forearm supination may serve as an alternative method for identifying a safe fixation zone that avoids proximal radioulnar joint impingement. Using this technique, all specimens demonstrated a full passive range of motion after plate placement, and the plates were positioned within the standard safe zone of the proximal radius.</div></div>","PeriodicalId":54815,"journal":{"name":"Journal of Hand Surgery-American Volume","volume":"51 9","pages":"Pages 971.e1-971.e7"},"PeriodicalIF":2.4000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Surgery-American Volume","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S036350232600122X","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

The radial head and neck feature a unique anatomical structure, whereby the application of a plate in certain areas can lead to impingement, subsequently restricting the forearm rotation. Various techniques have been suggested to identify the appropriate region for plate fixation. We propose an alternative method to locate a safe zone for plate placement and conduct a comparative analysis with previously established methods.

Methods

The study included 30 embalmed cadavers. All specimens demonstrated a full passive range of forearm rotation. A plate was positioned on the most anterior aspect of the radial head/neck with the forearm in full pronation (anteroposterior position) and on the most posterior aspect with the forearm in full supination (P-S position). We assessed the range of motion to identify proximal radioulnar joint impingement and compared the plate's positioning to the safe zone described by Caputo and Smith.

Results

All specimens maintained a full passive range of motion following plate fixation in all positions. The plate placement fell within the boundaries of Caputo's radial styloid direction and Smith's Lister's tubercle direction. The average plating zone measured 94°.

Conclusions

Positioning the plate at the most anterior aspect during forearm pronation or at the most posterior aspect during forearm supination may serve as an alternative method for identifying a safe fixation zone that avoids proximal radioulnar joint impingement. Using this technique, all specimens demonstrated a full passive range of motion after plate placement, and the plates were positioned within the standard safe zone of the proximal radius.
一种确定桡骨近端钢板内固定安全区域的简化方法。
目的:桡骨头颈具有独特的解剖结构,在某些区域应用钢板可导致撞击,从而限制前臂旋转。已经提出了各种技术来确定合适的钢板固定区域。我们提出了另一种方法来定位一个安全区域的板放置,并进行比较分析与先前建立的方法。方法:对30具尸体进行防腐处理。所有标本均表现出前臂完全被动旋转。在前臂完全旋前(前后位)时将钢板放置在桡骨头/颈的最前方,在前臂完全旋后(P-S位)时将钢板置于最后方。我们评估了活动范围以确定近端尺桡关节撞击,并将钢板的定位与Caputo和Smith描述的安全区域进行了比较。结果:所有标本在所有位置钢板固定后均保持完整的被动活动范围。钢板位置落在卡普托径向茎突方向和史密斯李斯特结节方向的边界内。平均镀区测量为94°。结论:前臂旋前时将钢板定位在最前方或前臂旋后时将钢板定位在最后方可作为确定安全固定区以避免近端尺桡关节撞击的替代方法。使用该技术,所有标本在钢板放置后均表现出完整的被动活动范围,并且钢板位于桡骨近端标准安全区域内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.20
自引率
10.50%
发文量
402
审稿时长
12 weeks
期刊介绍: The Journal of Hand Surgery publishes original, peer-reviewed articles related to the pathophysiology, diagnosis, and treatment of diseases and conditions of the upper extremity; these include both clinical and basic science studies, along with case reports. Special features include Review Articles (including Current Concepts and The Hand Surgery Landscape), Reviews of Books and Media, and Letters to the Editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书