Novel Ultrasound Technique to Evaluate the Superior Segment of the Internal Jugular Vein in Normal Subjects.

IF 1.1 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Ultrasound Quarterly Pub Date : 2026-03-19 eCollection Date: 2026-06-01 DOI:10.1097/RUQ.0000000000000724
Thanila A Macedo, Lynsey Claus, Duane D Meixner, Gina K Hesley, Nicholas B Larson, Thom W Rooke
{"title":"Novel Ultrasound Technique to Evaluate the Superior Segment of the Internal Jugular Vein in Normal Subjects.","authors":"Thanila A Macedo, Lynsey Claus, Duane D Meixner, Gina K Hesley, Nicholas B Larson, Thom W Rooke","doi":"10.1097/RUQ.0000000000000724","DOIUrl":null,"url":null,"abstract":"<p><p>A novel ultrasound technique was used to assess the superior segment of the internal jugular vein (IJV) in healthy individuals, evaluating the feasibility of visualizing this vein through the parotid gland and examining positional changes. Eighty-five patients undergoing unrelated carotid ultrasound were included, excluding those with headaches, migraines, or other neurological symptoms. A transducer was placed over the parotid gland, and gray scale images-with and without diameter measurement-and color and spectral Doppler of the IJV were obtained in neutral and head turned contralaterally. Technical feasibility and quantitative measurements with mean values and standard deviations were reported. Significant positional changes were assessed if paired data were available. Successful diameter measurements were obtained in at least one side in 79% to 80% of patients and bilaterally in 75%. Mean diameters were 5.5 cm (right) and 5 cm (left). Velocities were acquired in 82% (unilaterally) and 78% (bilaterally). Mean peak systolic velocities were 42 cm/s (right) and 32 cm/s (left). With head rotation, mean velocities were 46 cm/s (right) and 38 cm/s (left). In patients with paired measurements, velocities increased by over 50% in 19% to 28% of patients (P<0.05 for both sides). There was no significant change in the diameter when the head was turned. Visualization of the superior IJV using a parotid window and evaluation of its diameter and internal velocities are feasible with the head in both neutral position and turned contralaterally.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":"42 2","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2026-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Quarterly","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RUQ.0000000000000724","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

A novel ultrasound technique was used to assess the superior segment of the internal jugular vein (IJV) in healthy individuals, evaluating the feasibility of visualizing this vein through the parotid gland and examining positional changes. Eighty-five patients undergoing unrelated carotid ultrasound were included, excluding those with headaches, migraines, or other neurological symptoms. A transducer was placed over the parotid gland, and gray scale images-with and without diameter measurement-and color and spectral Doppler of the IJV were obtained in neutral and head turned contralaterally. Technical feasibility and quantitative measurements with mean values and standard deviations were reported. Significant positional changes were assessed if paired data were available. Successful diameter measurements were obtained in at least one side in 79% to 80% of patients and bilaterally in 75%. Mean diameters were 5.5 cm (right) and 5 cm (left). Velocities were acquired in 82% (unilaterally) and 78% (bilaterally). Mean peak systolic velocities were 42 cm/s (right) and 32 cm/s (left). With head rotation, mean velocities were 46 cm/s (right) and 38 cm/s (left). In patients with paired measurements, velocities increased by over 50% in 19% to 28% of patients (P<0.05 for both sides). There was no significant change in the diameter when the head was turned. Visualization of the superior IJV using a parotid window and evaluation of its diameter and internal velocities are feasible with the head in both neutral position and turned contralaterally.

新型超声技术评价正常人颈内静脉上段。
采用一种新的超声技术对健康人颈内静脉(IJV)上段进行评估,评估通过腮腺显像颈内静脉的可行性,并检查其位置变化。85名接受无关颈动脉超声检查的患者被纳入研究,排除了那些有头痛、偏头痛或其他神经症状的患者。在腮腺上放置换能器,在中性和头部侧转时获得灰度图像-有和没有直径测量-以及IJV的颜色和光谱多普勒。报告了技术可行性和定量测量的平均值和标准差。如果配对数据可用,评估显著的位置变化。79% - 80%的患者至少在一侧获得成功的直径测量,75%的患者在双侧获得成功的直径测量。平均直径为5.5 cm(右)和5 cm(左)。获得速度的82%(单侧)和78%(双侧)。平均峰值收缩速度为42 cm/s(右)和32 cm/s(左)。头部旋转时,平均速度为46 cm/s(右)和38 cm/s(左)。在配对测量的患者中,19%至28%的患者的速度增加了50%以上(P
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound Quarterly
Ultrasound Quarterly RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.50
自引率
7.70%
发文量
105
审稿时长
>12 weeks
期刊介绍: Ultrasound Quarterly provides coverage of the newest, most sophisticated ultrasound techniques as well as in-depth analysis of important developments in this dynamic field. The journal publishes reviews of a wide variety of topics including trans-vaginal ultrasonography, detection of fetal anomalies, color Doppler flow imaging, pediatric ultrasonography, and breast sonography. Official Journal of the Society of Radiologists in Ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书