The 68Ge/68Ga generator for enhancing productivity and reducing costs in nuclear medicine: experience from a university hospital

IF 3.7 Q1 CHEMISTRY, INORGANIC & NUCLEAR
EJNMMI Radiopharmacy and Chemistry Pub Date : 2026-03-13 Epub Date: 2026-04-21 DOI:10.1186/s41181-026-00437-z
Alessandra Guercio, Tess Martin, Silvia Migliari, Anna Gagliardi, Maura Scarlattei, Giorgio Baldari, Nicolas Martelli, Livia Ruffini
{"title":"The 68Ge/68Ga generator for enhancing productivity and reducing costs in nuclear medicine: experience from a university hospital","authors":"Alessandra Guercio,&nbsp;Tess Martin,&nbsp;Silvia Migliari,&nbsp;Anna Gagliardi,&nbsp;Maura Scarlattei,&nbsp;Giorgio Baldari,&nbsp;Nicolas Martelli,&nbsp;Livia Ruffini","doi":"10.1186/s41181-026-00437-z","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Sustainability in healthcare, particularly Nuclear Medicine, is essential, especially in managing radioactive materials. Traditional centralized production of Fluorine-18 tracers for PET imaging faces challenges like transport logistics, decay losses and supply chain vulnerabilities. Decentralized production with radionuclide generators, such as the Germanium-68/Gallium-68 (<sup>68</sup>Ge/<sup>68</sup>Ga) generator, offers on-demand isotope production, improving accessibility and precision imaging. This study evaluates the long-term performance (8 years) of <sup>68</sup>Ga-based radiopharmaceutical production in a Nuclear Medicine Division, focusing on efficiency, sustainability, and cost.</p><h3>Results</h3><p>Between 2016 and 2024, 416 batches of <sup>68</sup>GaCl₃ and 2455 batches of <sup>68</sup>Ga-based radiopharmaceuticals were produced. Data from systematic quality controls on generator eluates and tracers, such as <sup>68</sup>Ga-PSMA (1800 batches) and <sup>68</sup>Ga-DOTATOC (610 batches), were evaluated. All <sup>68</sup>GaCl₃ eluates met Ph. Eur. specifications, with negligible <sup>68</sup>Ge breakthrough (mean 0.0000068%) and consistently high radiochemical purity (100%). Radiopharmaceuticals showed stable quality over time, with &gt; 98% purity for <sup>68</sup>Ga-DOTATOC and &gt; 99% for <sup>68</sup>Ga-PSMA. Generators performance remained reliable, with an average elution yield of 74.8% (range 63.4–84.7%) and up to 466 elutions/year reached in 2024 without quality degradation. The correlation between estimated and measured end-of-synthesis activities was strong (R<sup>2</sup> ≈ 1), supporting accurate production planning. Clinical PET scans increased over sixfold, from 144 in 2016 to 920 in 2025. The high-sensitivity PET/CT system helped reduce injected activity and acquisition time, improving throughput and sustaining growth. The clinical-to-production ratio progressively decreased from 1 (1 batch/exam) to 0.42 for <sup>68</sup>Ga-PSMA (range 0.37–0.51) and 0.49 for <sup>68</sup>Ga-DOTATOC (range 0.40–0.60), indicating better batch utilization and workflow efficiency. Cost analysis showed module-based synthesis was most efficient during high-yield phases of the generators, while kit-based approaches were more cost-effective at later stages. Supply logistics of precursors and reagents has shown to be more sustainable for in-house production of radiopharmaceuticals compared to the purchased ones from external facilities.</p><h3>Conclusions</h3><p>The <sup>68</sup>Ge/<sup>68</sup>Ga generator supports reliable, sustainable, and cost-effective radiopharmaceutical production, enhancing efficiency and clinical capacity in PET imaging.</p></div>","PeriodicalId":534,"journal":{"name":"EJNMMI Radiopharmacy and Chemistry","volume":"11 1","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2026-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1186/s41181-026-00437-z.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Radiopharmacy and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s41181-026-00437-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Sustainability in healthcare, particularly Nuclear Medicine, is essential, especially in managing radioactive materials. Traditional centralized production of Fluorine-18 tracers for PET imaging faces challenges like transport logistics, decay losses and supply chain vulnerabilities. Decentralized production with radionuclide generators, such as the Germanium-68/Gallium-68 (68Ge/68Ga) generator, offers on-demand isotope production, improving accessibility and precision imaging. This study evaluates the long-term performance (8 years) of 68Ga-based radiopharmaceutical production in a Nuclear Medicine Division, focusing on efficiency, sustainability, and cost.

Results

Between 2016 and 2024, 416 batches of 68GaCl₃ and 2455 batches of 68Ga-based radiopharmaceuticals were produced. Data from systematic quality controls on generator eluates and tracers, such as 68Ga-PSMA (1800 batches) and 68Ga-DOTATOC (610 batches), were evaluated. All 68GaCl₃ eluates met Ph. Eur. specifications, with negligible 68Ge breakthrough (mean 0.0000068%) and consistently high radiochemical purity (100%). Radiopharmaceuticals showed stable quality over time, with > 98% purity for 68Ga-DOTATOC and > 99% for 68Ga-PSMA. Generators performance remained reliable, with an average elution yield of 74.8% (range 63.4–84.7%) and up to 466 elutions/year reached in 2024 without quality degradation. The correlation between estimated and measured end-of-synthesis activities was strong (R2 ≈ 1), supporting accurate production planning. Clinical PET scans increased over sixfold, from 144 in 2016 to 920 in 2025. The high-sensitivity PET/CT system helped reduce injected activity and acquisition time, improving throughput and sustaining growth. The clinical-to-production ratio progressively decreased from 1 (1 batch/exam) to 0.42 for 68Ga-PSMA (range 0.37–0.51) and 0.49 for 68Ga-DOTATOC (range 0.40–0.60), indicating better batch utilization and workflow efficiency. Cost analysis showed module-based synthesis was most efficient during high-yield phases of the generators, while kit-based approaches were more cost-effective at later stages. Supply logistics of precursors and reagents has shown to be more sustainable for in-house production of radiopharmaceuticals compared to the purchased ones from external facilities.

Conclusions

The 68Ge/68Ga generator supports reliable, sustainable, and cost-effective radiopharmaceutical production, enhancing efficiency and clinical capacity in PET imaging.

用于提高核医学生产力和降低成本的68Ge/68Ga发电机:来自某大学医院的经验。
背景:医疗保健,特别是核医学的可持续性至关重要,特别是在管理放射性材料方面。传统的用于PET成像的氟-18示踪剂的集中生产面临着运输物流、衰变损失和供应链脆弱性等挑战。分散生产放射性核素发生器,如锗-68/镓-68 (68Ge/68Ga)发生器,提供按需同位素生产,提高可及性和精度成像。本研究评估了核医学部门以68ga为基础的放射性药物生产的长期绩效(8年),重点关注效率、可持续性和成本。结果:2016 - 2024年共生产68GaCl₃416批,68ga基放射性药物2455批。对发生器洗脱液和示踪剂(如68Ga-PSMA(1800批次)和68Ga-DOTATOC(610批次))的系统质量控制数据进行评估。所有68GaCl₃淋洗液都满足Ph. Eur。规格,可忽略68Ge突破(平均0.0000068%)和持续高放射化学纯度(100%)。随着时间的推移,放射性药物的质量稳定,68Ga-DOTATOC的纯度为> 98%,68Ga-PSMA的纯度为> 99%。发电机的性能仍然可靠,平均洗脱率为74.8%(63.4-84.7%),2024年达到466次/年,质量没有下降。估计和测量的合成末端活性之间的相关性很强(R2≈1),支持准确的生产计划。临床PET扫描增加了六倍多,从2016年的144次增加到2025年的920次。高灵敏度PET/CT系统有助于降低注入活度和采集时间,提高产量并保持增长。对于68Ga-PSMA(范围0.37-0.51)和68Ga-DOTATOC(范围0.40-0.60),临床生产比逐渐从1(1批/次检查)下降到0.42,表明更好的批利用率和工作流程效率。成本分析表明,基于模块的合成方法在发电机高产阶段最有效,而基于套件的方法在后期阶段更具成本效益。前体和试剂的供应物流表明,与从外部设施购买相比,内部生产放射性药物更具可持续性。结论:68Ge/68Ga发生器支持可靠、可持续、高成本效益的放射性药物生产,提高了PET成像的效率和临床能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
8.70%
发文量
30
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书