Use of plasmapheresis during cardiopulmonary bypass in a pediatric heart transplant of a patient with Failing Fontan Physiology: first case in Argentina.

The journal of extra-corporeal technology Pub Date : 2026-03-01 Epub Date: 2026-03-13 DOI:10.1051/ject/2025053
Matias Jorge Martinez, Ignacio Berra, Javier Cornelis, Juan Costilla, Fernando Zamora, Pablo Garcia Delucis
{"title":"Use of plasmapheresis during cardiopulmonary bypass in a pediatric heart transplant of a patient with Failing Fontan Physiology: first case in Argentina.","authors":"Matias Jorge Martinez, Ignacio Berra, Javier Cornelis, Juan Costilla, Fernando Zamora, Pablo Garcia Delucis","doi":"10.1051/ject/2025053","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A 17-year-old male patient diagnosed with a single ventricle, in a failed Fontan stage, was evaluated prior to heart transplantation. The patient had a panel-reactive antibody (PRA) for human leucocyte antigen (HLA) I of 18% and for HLA II of 37%, so the decision was made to administer three doses of immunoglobulin while waiting for a donor heart.</p><p><strong>Methods: </strong>Once extracorporeal circulation was initiated, the apheresis machine extracted blood from the patient's venous drainage and returned it to the oxygenator reservoir. A total of 8278 mL of blood was processed, and 4224 mL of plasma was extracted. For replacement, 1341 mL of fresh frozen plasma and 2700 mL of 5% albumin were used. 75 mL of citrate-dextrose acid (CDA) was used as an anticoagulant. The procedure lasted 135 min.</p><p><strong>Results: </strong>On the tenth postoperative day, the PRA for HLA I and II was 0%. On the thirtieth postoperative day, a catheterization with endomyocardial biopsy showed no evidence of immunological rejection. An echocardiogram showed good function of the heart graft. One year later, a catheterization with endomyocardial biopsy showed no signs of humoral rejection. The patient is currently in the third-year post-transplant and continues to show no signs of rejection in their progression.</p><p><strong>Conclusion: </strong>Plasmapheresis during cardiopulmonary bypass is a reproducible, safe, and effective technique. It may be indicated for sensitized patients on the heart transplant waiting list.</p>","PeriodicalId":519952,"journal":{"name":"The journal of extra-corporeal technology","volume":"58 1","pages":"79-84"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12984029/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of extra-corporeal technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ject/2025053","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: A 17-year-old male patient diagnosed with a single ventricle, in a failed Fontan stage, was evaluated prior to heart transplantation. The patient had a panel-reactive antibody (PRA) for human leucocyte antigen (HLA) I of 18% and for HLA II of 37%, so the decision was made to administer three doses of immunoglobulin while waiting for a donor heart.

Methods: Once extracorporeal circulation was initiated, the apheresis machine extracted blood from the patient's venous drainage and returned it to the oxygenator reservoir. A total of 8278 mL of blood was processed, and 4224 mL of plasma was extracted. For replacement, 1341 mL of fresh frozen plasma and 2700 mL of 5% albumin were used. 75 mL of citrate-dextrose acid (CDA) was used as an anticoagulant. The procedure lasted 135 min.

Results: On the tenth postoperative day, the PRA for HLA I and II was 0%. On the thirtieth postoperative day, a catheterization with endomyocardial biopsy showed no evidence of immunological rejection. An echocardiogram showed good function of the heart graft. One year later, a catheterization with endomyocardial biopsy showed no signs of humoral rejection. The patient is currently in the third-year post-transplant and continues to show no signs of rejection in their progression.

Conclusion: Plasmapheresis during cardiopulmonary bypass is a reproducible, safe, and effective technique. It may be indicated for sensitized patients on the heart transplant waiting list.

血浆置换术在小儿心脏移植中体外循环的应用:阿根廷首例Fontan生理功能衰竭患者。
背景:一名17岁男性患者被诊断为单心室,在Fontan期失败,在心脏移植前进行了评估。患者对人类白细胞抗原(HLA) I和HLA II的整体反应性抗体(PRA)分别为18%和37%,因此决定在等待供体心脏时给予三剂免疫球蛋白。方法:体外循环启动后,采血机从患者静脉引流液中提取血液,并将其回流到氧合器储血器中。共处理血液8278 mL,提取血浆4224 mL。替换用1341 mL新鲜冷冻血浆和2700 mL 5%白蛋白。75ml柠檬酸-葡萄糖酸(CDA)作为抗凝剂。整个过程持续了135分钟。结果:术后第10天,HLA I和HLA II的PRA均为0%。术后第30天,心内肌活检导管穿刺未发现免疫排斥反应。超声心动图显示移植心脏功能良好。一年后,导管穿刺心肌膜活检显示没有体液排斥的迹象。该患者目前处于移植后的第三年,在其进展过程中仍未出现排斥反应的迹象。结论:体外循环血浆置换术是一种可重复、安全、有效的技术。它可能适用于心脏移植等待名单上的敏感患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书