Initiating cardiopulmonary bypass using a dry venous line: implications and analysis.

The journal of extra-corporeal technology Pub Date : 2026-03-01 Epub Date: 2026-03-13 DOI:10.1051/ject/2025034
Tristan Benedict, Robert Brownlee, Christopher Foley, Nathan Hoyer, Laura Dell'Aiera, Mary Dooley, Dave Fitzgerald
{"title":"Initiating cardiopulmonary bypass using a dry venous line: implications and analysis.","authors":"Tristan Benedict, Robert Brownlee, Christopher Foley, Nathan Hoyer, Laura Dell'Aiera, Mary Dooley, Dave Fitzgerald","doi":"10.1051/ject/2025034","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Autologous priming of the cardiopulmonary bypass (CPB) circuit is a critical technique for reducing hemodilution during cardiac surgery. Vacuum-assisted venous drainage (VAVD) offers access to an alternative method using a dry venous line, aiming to reduce hemodilution associated with crystalloid priming.</p><p><strong>Methods: </strong>This study investigates the impact of initiating CPB with a dry venous line on gaseous microemboli (GME) production, compared to a traditional primed venous line in an adult CPB circuit. Using a controlled experimental setup with an oxygenator featuring an integrated arterial filter, we examined GME counts and sizes throughout the circuit under varying VAVD pressures and initiation techniques.</p><p><strong>Results: </strong>Results show that higher VAVD pressures and the immediate initiation of CPB correlate with increased GME production post-oxygenator. Statistical analysis reveals significant differences in GME counts and sizes between control and experimental groups.</p><p><strong>Conclusion: </strong>The statistical differences in GME size and count observed between initiation types and pressures emphasize the importance of optimal CPB initiation strategies to minimize GME transmission. These findings underscore the need for further research to refine CPB techniques and enhance patient safety in cardiac surgery.</p>","PeriodicalId":519952,"journal":{"name":"The journal of extra-corporeal technology","volume":"58 1","pages":"65-72"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12984041/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of extra-corporeal technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ject/2025034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Autologous priming of the cardiopulmonary bypass (CPB) circuit is a critical technique for reducing hemodilution during cardiac surgery. Vacuum-assisted venous drainage (VAVD) offers access to an alternative method using a dry venous line, aiming to reduce hemodilution associated with crystalloid priming.

Methods: This study investigates the impact of initiating CPB with a dry venous line on gaseous microemboli (GME) production, compared to a traditional primed venous line in an adult CPB circuit. Using a controlled experimental setup with an oxygenator featuring an integrated arterial filter, we examined GME counts and sizes throughout the circuit under varying VAVD pressures and initiation techniques.

Results: Results show that higher VAVD pressures and the immediate initiation of CPB correlate with increased GME production post-oxygenator. Statistical analysis reveals significant differences in GME counts and sizes between control and experimental groups.

Conclusion: The statistical differences in GME size and count observed between initiation types and pressures emphasize the importance of optimal CPB initiation strategies to minimize GME transmission. These findings underscore the need for further research to refine CPB techniques and enhance patient safety in cardiac surgery.

Abstract Image

Abstract Image

Abstract Image

使用干静脉线启动体外循环:意义和分析。
背景:体外循环(CPB)回路的自体启动是心脏手术中减少血液稀释的关键技术。真空辅助静脉引流(VAVD)提供了一种使用干静脉线的替代方法,旨在减少与晶体启动相关的血液稀释。方法:本研究调查了与成人CPB回路中传统的启动静脉线相比,用干静脉线启动CPB对气体微栓子(GME)产生的影响。使用一个带有集成动脉过滤器的氧合器的受控实验装置,我们在不同的VAVD压力和启动技术下检查了整个电路中的GME计数和大小。结果:结果表明,较高的VAVD压力和CPB的立即启动与氧合器后GME产生的增加有关。统计分析显示对照组和实验组GME计数和大小有显著差异。结论:不同启动类型和压力下GME大小和数量的统计学差异强调了最佳CPB启动策略对减少GME传播的重要性。这些发现强调需要进一步研究以完善CPB技术并提高心脏手术患者的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书