{"title":"Control, reliability analysis, and intelligent energy management optimization for resilient multi-pump irrigation system powered by DFIG-based wind energy system","authors":"Salah Tamalouzt ,&nbsp;Karim Fathi Sayeh ,&nbsp;Kamel Djermouni ,&nbsp;Youcef Belkhier ,&nbsp;Abdelkrim Hamasse","doi":"10.1016/j.rico.2026.100668","DOIUrl":null,"url":null,"abstract":"<div><div>The present paper puts forth a state-of-the-art control strategy for a Doubly Fed Induction Generator (DFIG)-based wind energy conversion system that supplies a multi-pump irrigation network. In order to surmount the power quality limitations inherent to conventional Direct Torque Control (DTC), a Fuzzy Logic–based Improved Direct Reactive Power Control (F-IDRPC) approach has been developed. The conventional hysteresis comparators and switching table are substituted by a fuzzy inference system, a modification that results in a substantial reduction of torque, flux, and current ripples, while ensuring the maintenance of near-sinusoidal stator currents. Furthermore, a Reliability-Aware Permutation Strategy (RAPS) is integrated into the Smart Energy Management Approach (SEMA) algorithm. By replacing a single high-power pump with a modular five-pump architecture, the proposed method increases system reliability by 226% (MTBF) and equalizes mechanical wear through cyclic duty cycling. The MATLAB/Simulink simulation. The MATLAB/Simulink simulation results demonstrate a 99.15% reduction in Total Harmonic Distortion (THD), an 48.25% reduction in active power ripples, and a 55.23% reduction in local reactive power compensation ripples, with a 90.04% reduction in frequency ripples compared with conventional control. These findings substantiate the efficacy of the proposed strategy in enhancing power quality, system stability, and irrigation reliability under variable wind conditions.</div></div>","PeriodicalId":34733,"journal":{"name":"Results in Control and Optimization","volume":"22 ","pages":"Article 100668"},"PeriodicalIF":3.8000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Results in Control and Optimization","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666720726000159","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 0

Abstract

The present paper puts forth a state-of-the-art control strategy for a Doubly Fed Induction Generator (DFIG)-based wind energy conversion system that supplies a multi-pump irrigation network. In order to surmount the power quality limitations inherent to conventional Direct Torque Control (DTC), a Fuzzy Logic–based Improved Direct Reactive Power Control (F-IDRPC) approach has been developed. The conventional hysteresis comparators and switching table are substituted by a fuzzy inference system, a modification that results in a substantial reduction of torque, flux, and current ripples, while ensuring the maintenance of near-sinusoidal stator currents. Furthermore, a Reliability-Aware Permutation Strategy (RAPS) is integrated into the Smart Energy Management Approach (SEMA) algorithm. By replacing a single high-power pump with a modular five-pump architecture, the proposed method increases system reliability by 226% (MTBF) and equalizes mechanical wear through cyclic duty cycling. The MATLAB/Simulink simulation. The MATLAB/Simulink simulation results demonstrate a 99.15% reduction in Total Harmonic Distortion (THD), an 48.25% reduction in active power ripples, and a 55.23% reduction in local reactive power compensation ripples, with a 90.04% reduction in frequency ripples compared with conventional control. These findings substantiate the efficacy of the proposed strategy in enhancing power quality, system stability, and irrigation reliability under variable wind conditions.
基于dfig风能系统的弹性多泵灌溉系统控制、可靠性分析及智能能源管理优化
本文提出了一种基于双馈感应发电机(DFIG)的风能转换系统的最先进的控制策略,该系统提供多泵灌溉网络。为了克服传统直接转矩控制(DTC)固有的电能质量限制,提出了一种基于模糊逻辑的改进型直接无功功率控制(F-IDRPC)方法。传统的迟滞比较器和开关表被模糊推理系统所取代,这种修改导致转矩、磁通和电流波动的大幅减少,同时确保维持近正弦的定子电流。此外,将可靠性感知置换策略(RAPS)集成到智能能源管理方法(SEMA)算法中。通过将单个大功率泵替换为模块化的五泵结构,该方法将系统可靠性提高了226% (MTBF),并通过循环占空循环均衡机械磨损。MATLAB/Simulink仿真。MATLAB/Simulink仿真结果表明,与传统控制相比,总谐波失真(THD)降低99.15%,有功功率纹波降低48.25%,局部无功补偿纹波降低55.23%,频率纹波降低90.04%。这些发现证实了所提出的策略在提高电能质量、系统稳定性和可变风条件下灌溉可靠性方面的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Results in Control and Optimization
Results in Control and Optimization Mathematics-Control and Optimization
CiteScore
3.00
自引率
0.00%
发文量
51
审稿时长
91 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书