{"title":"Re-operative hemi-commando operation without a homograft: an alternative approach for complex aortic root abscess.","authors":"Kyle McCullough, Dina Al Rameni, Suguru Ohira","doi":"10.1510/mmcts.2025.165","DOIUrl":null,"url":null,"abstract":"<p><p>The patient was in his late 70s with a prior history of aortic valve replacement, recent emergent percutaneous coronary intervention for the right coronary artery (RCA), and a chronic type A aortic dissection and a 6-cm ascending aortic aneurysm. He developed Staphylococcus epidermidis bacteraemia and was found to have an aortic root abscess. Echocardiography demonstrated dehiscence of the aortic bioprosthesis with an aortic root abscess and moderate-to-severe mitral regurgitation. Radical debridement was performed, including resection of the aorto-mitral curtain through an extended transseptal approach. The protruding RCA stent was partially resected to allow selective cardioplegia. Mitral valve repair was performed with implantation of a 30-mm partial annuloplasty ring. A rectangular double-patch technique was used. The first bovine pericardial patch was sewn to the dome of the left atrium, and the second patch reconstructed the aortic annulus, with reinforcement of the fibrous trigones using pledgeted sutures. A handmade composite Bentall graft was constructed using a 30-mm Dacron graft with a skirted 25-mm bioprosthesis, and implanted with non-everting sutures. Both coronary buttons were reimplanted, followed by hemiarch replacement. The right atrium was closed with a separate pericardial patch, and a saphenous vein graft was placed to the distal RCA.</p>","PeriodicalId":53474,"journal":{"name":"Multimedia manual of cardiothoracic surgery : MMCTS / European Association for Cardio-Thoracic Surgery","volume":"2026 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Multimedia manual of cardiothoracic surgery : MMCTS / European Association for Cardio-Thoracic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1510/mmcts.2025.165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
The patient was in his late 70s with a prior history of aortic valve replacement, recent emergent percutaneous coronary intervention for the right coronary artery (RCA), and a chronic type A aortic dissection and a 6-cm ascending aortic aneurysm. He developed Staphylococcus epidermidis bacteraemia and was found to have an aortic root abscess. Echocardiography demonstrated dehiscence of the aortic bioprosthesis with an aortic root abscess and moderate-to-severe mitral regurgitation. Radical debridement was performed, including resection of the aorto-mitral curtain through an extended transseptal approach. The protruding RCA stent was partially resected to allow selective cardioplegia. Mitral valve repair was performed with implantation of a 30-mm partial annuloplasty ring. A rectangular double-patch technique was used. The first bovine pericardial patch was sewn to the dome of the left atrium, and the second patch reconstructed the aortic annulus, with reinforcement of the fibrous trigones using pledgeted sutures. A handmade composite Bentall graft was constructed using a 30-mm Dacron graft with a skirted 25-mm bioprosthesis, and implanted with non-everting sutures. Both coronary buttons were reimplanted, followed by hemiarch replacement. The right atrium was closed with a separate pericardial patch, and a saphenous vein graft was placed to the distal RCA.
期刊介绍:
The Multimedia Manual of Cardio-Thoracic Surgery (MMCTS) is produced by The European Association for Cardio-Thoracic Surgery (EACTS). MMCTS is the world’s premier video-based educational resource for cardiovascular and thoracic surgeons; freely accessible - and essential - for all. MMCTS was launched more than ten years ago under the leadership of founding editor Professor Marko Turina. It was Professor Turina’s vision that the European Association for Cardio-Thoracic Surgery (EACTS), already the world-leader in CT surgery education, should take advantage of the Internet’s rapidly improving video publication capabilities and create a new step-by-step manual of surgical procedures. Professor Turina and EACTS agreed that the manual, MMCTS, should be freely accessible to all users, regardless of association membership status, nationality, or affiliation. MMCTS was self-published by EACTS for some years before being transferred to Oxford University Press, which hosted it until the end of 2016. In November 2016, the Manual returned home to EACTS and it has now relaunched in a completely new format. Since its birth in 2005, MMCTS has published some 400 detailed, video-based demonstrations of cardio-thoracic surgical procedures. Tutorials published prior to 2012 have been archived and we are working with the authors of these tutorials to update their work pending republication on the new site. Our mission is to make MMCTS the best online reference for cardio-thoracic surgeons – residents and experienced surgeons alike. Our aim is to include tutorials presenting procedures at both a fundamental and an advanced level. Truly innovative procedures are also included and are identified as such.