Leila R. Zelnick, Subbulaxmi Trikudanathan, Yoshio N. Hall, Ernest Ayers, Lisa Anderson, Nathaniel Ashford, Evelin Jones, Andrea C. Rivas-Nieto, Simon Hsu, Kuanysh Kabytaev, Zhuo Wang, Andrew N. Hoofnagle, Irl B. Hirsch, Ian H. de Boer
{"title":"Accuracy, Variability, and Bias of Glycemic Biomarkers in Patients Treated With Maintenance Dialysis","authors":"Leila R. Zelnick, Subbulaxmi Trikudanathan, Yoshio N. Hall, Ernest Ayers, Lisa Anderson, Nathaniel Ashford, Evelin Jones, Andrea C. Rivas-Nieto, Simon Hsu, Kuanysh Kabytaev, Zhuo Wang, Andrew N. Hoofnagle, Irl B. Hirsch, Ian H. de Boer","doi":"10.2337/dc25-2952","DOIUrl":null,"url":null,"abstract":"OBJECTIVE Accurate assessment of glycemia in patients treated with maintenance dialysis is imperative and hampered by known biases of glycated hemoglobin (HbA1c) in kidney failure (KF). This study evaluated the accuracy, variability, and covariate bias of three glycemic biomarkers compared with glycemia measured by continuous glucose monitor (CGM) among people with and without diabetes treated with maintenance dialysis. RESEARCH DESIGN AND METHODS In a prospective community-based cohort study, 251 participants treated with maintenance dialysis wore a Dexcom G6 Pro CGM for 10 days. We compared correlations of HbA1c, glycated albumin (GA), and fructosamine with CGM-derived mean glycemia and examined sources of bias. RESULTS Participants (43% women; 63% with diabetes) had a median of 9.3 (interquartile range 8.5–9.4) valid days of CGM data. Mean (SD) HbA1c, GA, fructosamine, and mean CGM glucose were 6.2% (1.4%), 19.6% (6.3%), 351 (99) µmol/L, and 170 (63) mg/dL, respectively. HbA1c, GA, and fructosamine all strongly correlated with mean CGM blood glucose, with HbA1c and GA more correlated than fructosamine (overall, r = 0.85, r = 0.87, and r = 0.70, respectively; in diabetes, r = 0.84, r = 0.84, and r = 0.64, respectively). Compared with mean CGM glucose, HbA1c was significantly biased by erythropoiesis-stimulating agent dose, BMI, hemoglobin, and serum albumin; GA and fructosamine were biased by dialysis modality and vintage, residual kidney function, and BMI. CONCLUSIONS HbA1c and GA were strongly correlated with mean CGM blood glucose, but all biomarkers had substantial bias by relevant clinical characteristics. HbA1c and GA may be useful assessments of average glycemia in patients treated with maintenance dialysis, if bias can be adequately addressed.","PeriodicalId":11140,"journal":{"name":"Diabetes Care","volume":"80 1","pages":""},"PeriodicalIF":22.6000,"publicationDate":"2026-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2337/dc25-2952","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
OBJECTIVE Accurate assessment of glycemia in patients treated with maintenance dialysis is imperative and hampered by known biases of glycated hemoglobin (HbA1c) in kidney failure (KF). This study evaluated the accuracy, variability, and covariate bias of three glycemic biomarkers compared with glycemia measured by continuous glucose monitor (CGM) among people with and without diabetes treated with maintenance dialysis. RESEARCH DESIGN AND METHODS In a prospective community-based cohort study, 251 participants treated with maintenance dialysis wore a Dexcom G6 Pro CGM for 10 days. We compared correlations of HbA1c, glycated albumin (GA), and fructosamine with CGM-derived mean glycemia and examined sources of bias. RESULTS Participants (43% women; 63% with diabetes) had a median of 9.3 (interquartile range 8.5–9.4) valid days of CGM data. Mean (SD) HbA1c, GA, fructosamine, and mean CGM glucose were 6.2% (1.4%), 19.6% (6.3%), 351 (99) µmol/L, and 170 (63) mg/dL, respectively. HbA1c, GA, and fructosamine all strongly correlated with mean CGM blood glucose, with HbA1c and GA more correlated than fructosamine (overall, r = 0.85, r = 0.87, and r = 0.70, respectively; in diabetes, r = 0.84, r = 0.84, and r = 0.64, respectively). Compared with mean CGM glucose, HbA1c was significantly biased by erythropoiesis-stimulating agent dose, BMI, hemoglobin, and serum albumin; GA and fructosamine were biased by dialysis modality and vintage, residual kidney function, and BMI. CONCLUSIONS HbA1c and GA were strongly correlated with mean CGM blood glucose, but all biomarkers had substantial bias by relevant clinical characteristics. HbA1c and GA may be useful assessments of average glycemia in patients treated with maintenance dialysis, if bias can be adequately addressed.
期刊介绍:
The journal's overarching mission can be captured by the simple word "Care," reflecting its commitment to enhancing patient well-being. Diabetes Care aims to support better patient care by addressing the comprehensive needs of healthcare professionals dedicated to managing diabetes.
Diabetes Care serves as a valuable resource for healthcare practitioners, aiming to advance knowledge, foster research, and improve diabetes management. The journal publishes original research across various categories, including Clinical Care, Education, Nutrition, Psychosocial Research, Epidemiology, Health Services Research, Emerging Treatments and Technologies, Pathophysiology, Complications, and Cardiovascular and Metabolic Risk. Additionally, Diabetes Care features ADA statements, consensus reports, review articles, letters to the editor, and health/medical news, appealing to a diverse audience of physicians, researchers, psychologists, educators, and other healthcare professionals.