{"title":"Stability of Bence Jones protein in refrigerated urine samples over five days: a preanalytical evaluation.","authors":"Maria Rita Cozzi, Fabio Del Ben, Martina Amato, Romina Boschian, Claudio Buciol, Chiara Corso, Cinzia Crepaldi, Tamara Damian, Riccardo De Appollonia, Katya Gaspardo, Fabiana Giordari, Matteo Turetta, Francesco Volpi, Agostino Steffan","doi":"10.1515/dx-2025-0183","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study investigates the short-term stability of Bence Jones protein (BJP) in refrigerated urine samples stored over a period of 5 days. The aim was to evaluate whether BJP concentrations remain consistent when urine specimens are refrigerated and analyzed over time.</p><p><strong>Methods: </strong>Urine samples were collected from 20 plasma cell dyscrasia patients with BJP for a total of 30 independent time-series and 83 data-points. Measurements were performed at five time points: Day 0 (baseline), and Days 1 through 4. Percentage difference (PD%) from baseline was used to quantify temporal change.</p><p><strong>Results: </strong>The median baseline BJP M-spike percentage was 54 % (range: 17-87 %), covering a wide range of total urinary protein (median 296 mg/L, range 64-3,094 mg/L). PD% ranged from -2 % on Day 3 to +7 % on Day 1, with no statistically significant trend over time. The derived instability equation, PD%=0.33 × time (days), yielded r= -0.03 and p=0.77, indicated negligible instability.</p><p><strong>Conclusions: </strong>These findings demonstrate acceptable short-term stability of BJP in refrigerated urine over 5 days, supporting its use in routine laboratory workflows involving delayed analysis.</p>","PeriodicalId":11273,"journal":{"name":"Diagnosis","volume":" ","pages":"485-491"},"PeriodicalIF":1.9000,"publicationDate":"2026-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/dx-2025-0183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: This study investigates the short-term stability of Bence Jones protein (BJP) in refrigerated urine samples stored over a period of 5 days. The aim was to evaluate whether BJP concentrations remain consistent when urine specimens are refrigerated and analyzed over time.
Methods: Urine samples were collected from 20 plasma cell dyscrasia patients with BJP for a total of 30 independent time-series and 83 data-points. Measurements were performed at five time points: Day 0 (baseline), and Days 1 through 4. Percentage difference (PD%) from baseline was used to quantify temporal change.
Results: The median baseline BJP M-spike percentage was 54 % (range: 17-87 %), covering a wide range of total urinary protein (median 296 mg/L, range 64-3,094 mg/L). PD% ranged from -2 % on Day 3 to +7 % on Day 1, with no statistically significant trend over time. The derived instability equation, PD%=0.33 × time (days), yielded r= -0.03 and p=0.77, indicated negligible instability.
Conclusions: These findings demonstrate acceptable short-term stability of BJP in refrigerated urine over 5 days, supporting its use in routine laboratory workflows involving delayed analysis.
期刊介绍:
Diagnosis focuses on how diagnosis can be advanced, how it is taught, and how and why it can fail, leading to diagnostic errors. The journal welcomes both fundamental and applied works, improvement initiatives, opinions, and debates to encourage new thinking on improving this critical aspect of healthcare quality. Topics: -Factors that promote diagnostic quality and safety -Clinical reasoning -Diagnostic errors in medicine -The factors that contribute to diagnostic error: human factors, cognitive issues, and system-related breakdowns -Improving the value of diagnosis – eliminating waste and unnecessary testing -How culture and removing blame promote awareness of diagnostic errors -Training and education related to clinical reasoning and diagnostic skills -Advances in laboratory testing and imaging that improve diagnostic capability -Local, national and international initiatives to reduce diagnostic error