Does the extended use of anaesthetic breathing circuits increase microbial contamination? A systematic review and meta-analysis.

IF 1.5 4区 医学 Q3 ANESTHESIOLOGY
Anaesthesia and Intensive Care Pub Date : 2026-03-01 Epub Date: 2025-10-14 DOI:10.1177/0310057X251377312
Daniel C Y Cheng, Aolei Yu, Andrew Lindberg, Jo Tallon, Benjamin L Olesnicky
{"title":"Does the extended use of anaesthetic breathing circuits increase microbial contamination? A systematic review and meta-analysis.","authors":"Daniel C Y Cheng, Aolei Yu, Andrew Lindberg, Jo Tallon, Benjamin L Olesnicky","doi":"10.1177/0310057X251377312","DOIUrl":null,"url":null,"abstract":"<p><p>Hospitals, and in particular operating theatres, contribute significantly to the carbon footprint of modern healthcare. Operating theatres account for a large part of hospital waste, which can be offset by using more reusable or recyclable equipment. However, environmentally sustainable decisions within healthcare need to be evaluated to ensure they can be introduced without a negative impact on patient safety or outcomes. We performed a systematic review and meta-analysis to evaluate the difference in the rates of microbiological contamination of anaesthetic breathing circuits between single day or extended (more than one day) use in the provision of general anaesthesia in adult patients, where a microbial filter was used and changed for each patient regardless of the duration of breathing circuit usage. The results demonstrate no significant increase in the rate of contamination between single day and extended use breathing circuits (odds ratio (OR): 0.84; 95% confidence interval (CI): 0.44 to 1.60) or single day and seven-day breathing circuits (OR: 1.30, 95% CI: 0.34 to 4.97). This supports the use of extended use breathing circuits for up to seven days for both the demonstrated environmental and financial benefits, with no evidence of compromise to patient safety.</p>","PeriodicalId":7746,"journal":{"name":"Anaesthesia and Intensive Care","volume":"54 2","pages":"125-132"},"PeriodicalIF":1.5000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesia and Intensive Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/0310057X251377312","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Hospitals, and in particular operating theatres, contribute significantly to the carbon footprint of modern healthcare. Operating theatres account for a large part of hospital waste, which can be offset by using more reusable or recyclable equipment. However, environmentally sustainable decisions within healthcare need to be evaluated to ensure they can be introduced without a negative impact on patient safety or outcomes. We performed a systematic review and meta-analysis to evaluate the difference in the rates of microbiological contamination of anaesthetic breathing circuits between single day or extended (more than one day) use in the provision of general anaesthesia in adult patients, where a microbial filter was used and changed for each patient regardless of the duration of breathing circuit usage. The results demonstrate no significant increase in the rate of contamination between single day and extended use breathing circuits (odds ratio (OR): 0.84; 95% confidence interval (CI): 0.44 to 1.60) or single day and seven-day breathing circuits (OR: 1.30, 95% CI: 0.34 to 4.97). This supports the use of extended use breathing circuits for up to seven days for both the demonstrated environmental and financial benefits, with no evidence of compromise to patient safety.

麻醉呼吸回路的长期使用是否会增加微生物污染?系统回顾和荟萃分析。
医院,特别是手术室,对现代医疗保健的碳足迹贡献巨大。手术室占医院废物的很大一部分,这可以通过使用更多的可重复使用或可回收的设备来抵消。然而,需要对医疗保健中的环境可持续决策进行评估,以确保它们的引入不会对患者安全或结果产生负面影响。我们进行了一项系统回顾和荟萃分析,以评估在提供全身麻醉的成年患者中,使用一天或延长(超过一天)麻醉呼吸回路的微生物污染率的差异,在这种情况下,无论呼吸回路使用的持续时间长短,每个患者都使用和更换微生物过滤器。结果表明,单天和长时间使用呼吸回路之间的污染率没有显著增加(优势比(OR): 0.84;95%置信区间(CI): 0.44至1.60)或单日和7天呼吸循环(or: 1.30, 95% CI: 0.34至4.97)。这支持使用长达7天的延长使用呼吸回路,既证明了环境效益,也证明了经济效益,没有证据表明会危及患者安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.70
自引率
13.30%
发文量
150
审稿时长
3 months
期刊介绍: Anaesthesia and Intensive Care is an international journal publishing timely, peer reviewed articles that have educational value and scientific merit for clinicians and researchers associated with anaesthesia, intensive care medicine, and pain medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书