Normative data on extensor pollicis longus force, lift-off height, and tendon gliding amplitude

IF 1.8 4区 医学 Q2 ORTHOPEDICS
Journal of Hand Therapy Pub Date : 2026-07-01 Epub Date: 2026-03-03 DOI:10.1016/j.jht.2025.12.010
Christos Ni Sarigiannis MD, MSc, Ingrid Andreasson OT, PhD, Lars Ekström BS, Michael Ullman MD, PhD, Anders Björkman MD, PhD
{"title":"Normative data on extensor pollicis longus force, lift-off height, and tendon gliding amplitude","authors":"Christos Ni Sarigiannis MD, MSc,&nbsp;Ingrid Andreasson OT, PhD,&nbsp;Lars Ekström BS,&nbsp;Michael Ullman MD, PhD,&nbsp;Anders Björkman MD, PhD","doi":"10.1016/j.jht.2025.12.010","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The extensor pollicis longus is the principal extensor of the thumb and is typically evaluated in clinical examination with the hand placed flat on a surface. As the hand is commonly immobilized or functions in 20-30 degrees of wrist extension (the functional position), it is important to understand extensor pollicis longus function in both positions.</div></div><div><h3>Purpose</h3><div>To establish normative reference values for extensor pollicis longus extension force measured with the hand in flat and functional positions and assess normative values for lift-off height and extensor pollicis longus tendon gliding amplitude.</div></div><div><h3>Study Design</h3><div>Cross-sectional study.</div></div><div><h3>Methods</h3><div>Two hundred healthy individuals (100 males, 100 females; aged 18-85 years, median age 46 years) were included. A custom-made device capable of measuring isolated finger force and recording electromyographic activity was used. Lift-off test height and extensor pollicis longus tendon gliding amplitude were documented.</div></div><div><h3>Results</h3><div>Extensor pollicis longus force peaked in the third decade of life and declined thereafter. In the flat position, the median extension force was 9.3 N (range: 1.1-18.8 N) for females and 15.8 N (range: 6.4-33.0 N) for males. In the functional position, the median values were 14.0 N (range: 3.8-35.2 N) for females and 21.2 N (range: 6.4-50.6 N) for males. Lift-off height was comparable between the sexes, with median values from 46 to 48 mm (range: 10-75 mm). Likewise, gliding amplitude exhibited no differences between the sexes, with a median of 30 mm (range: 5-50 mm).</div></div><div><h3>Conclusions</h3><div>Reference values for extensor pollicis longus extension force, lift-off height, and tendon gliding amplitude were established. Maximal force occurs at 30 degrees wrist extension, peaks in the third decade, and declines after the fourth. On average, force values in females were approximately 60% of those observed in males.</div></div>","PeriodicalId":54814,"journal":{"name":"Journal of Hand Therapy","volume":"39 3","pages":"Pages 610-619"},"PeriodicalIF":1.8000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Therapy","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0894113025002091","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/3 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

The extensor pollicis longus is the principal extensor of the thumb and is typically evaluated in clinical examination with the hand placed flat on a surface. As the hand is commonly immobilized or functions in 20-30 degrees of wrist extension (the functional position), it is important to understand extensor pollicis longus function in both positions.

Purpose

To establish normative reference values for extensor pollicis longus extension force measured with the hand in flat and functional positions and assess normative values for lift-off height and extensor pollicis longus tendon gliding amplitude.

Study Design

Cross-sectional study.

Methods

Two hundred healthy individuals (100 males, 100 females; aged 18-85 years, median age 46 years) were included. A custom-made device capable of measuring isolated finger force and recording electromyographic activity was used. Lift-off test height and extensor pollicis longus tendon gliding amplitude were documented.

Results

Extensor pollicis longus force peaked in the third decade of life and declined thereafter. In the flat position, the median extension force was 9.3 N (range: 1.1-18.8 N) for females and 15.8 N (range: 6.4-33.0 N) for males. In the functional position, the median values were 14.0 N (range: 3.8-35.2 N) for females and 21.2 N (range: 6.4-50.6 N) for males. Lift-off height was comparable between the sexes, with median values from 46 to 48 mm (range: 10-75 mm). Likewise, gliding amplitude exhibited no differences between the sexes, with a median of 30 mm (range: 5-50 mm).

Conclusions

Reference values for extensor pollicis longus extension force, lift-off height, and tendon gliding amplitude were established. Maximal force occurs at 30 degrees wrist extension, peaks in the third decade, and declines after the fourth. On average, force values in females were approximately 60% of those observed in males.
拇长伸肌力、提离高度和肌腱滑动幅度的规范数据。
背景:拇长伸肌是拇指的主要伸肌,通常在临床检查时将手平放在一个表面上进行评估。由于手通常固定在手腕伸展20-30度(功能位置),因此了解这两个位置的拇长伸肌功能非常重要。目的:建立手在平位和功能位测量拇长伸肌伸力的规范参考值,并评估拇长伸肌肌腱升降高度和滑动幅度的规范值。研究设计:横断面研究。方法:纳入健康个体200例(男100例,女100例,年龄18 ~ 85岁,中位年龄46岁)。一个定制的装置能够测量孤立的手指力和记录肌电活动。记录了吊离试验高度和拇长伸肌腱滑动幅度。结果:拇长伸肌力在30岁时达到峰值,此后逐渐下降。平卧位时,雌性的中位伸力为9.3 N(范围1.1 ~ 18.8 N),雄性为15.8 N(范围6.4 ~ 33.0 N)。在功能位,女性的中位值为14.0 N(范围:3.8-35.2 N),男性为21.2 N(范围:6.4-50.6 N)。起飞高度在两性之间具有可比性,中位数为46至48毫米(范围:10-75毫米)。同样,滑翔幅度在两性之间也没有差异,中位数为30毫米(范围:5-50毫米)。结论:建立了拇长伸肌伸力、提离高度和肌腱滑动幅度的参考值。最大力量出现在手腕伸展30度时,在第三个十年达到顶峰,在第四个十年之后下降。平均而言,女性的力值约为男性的60%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Hand Therapy
Journal of Hand Therapy 医学-外科
CiteScore
3.50
自引率
10.00%
发文量
65
审稿时长
19.2 weeks
期刊介绍: The Journal of Hand Therapy is designed for hand therapists, occupational and physical therapists, and other hand specialists involved in the rehabilitation of disabling hand problems. The Journal functions as a source of education and information by publishing scientific and clinical articles. Regular features include original reports, clinical reviews, case studies, editorials, and book reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书