{"title":"Automating virtual dental implant planning: can artificial intelligence match clinical expertise?","authors":"Bahaaeldeen M Elgarba, Eslam Abdelwahab Dawood, Rocharles Cavalcante Fontenele, Pierre Lahoud, Jan Meeus, Reinhilde Jacobs","doi":"10.1093/dmfr/twag015","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study evaluated a validated artificial intelligence (AI) tool for virtual implant planning by comparing its performance with expert-planned and clinically placed implants in single-tooth rehabilitation cases.</p><p><strong>Methods: </strong>Pre- and postoperative cone-beam CT (CBCT) scans were retrospectively collected from 32 single-tooth implant cases. Actual implants were placed by expert clinicians using a human intelligence (HI)-based approach guided by the preoperative CBCT. The same scans were used to generate both AI- and HI-based virtual implant plans. Pre- and postoperative scans were registered to allow accurate comparison between placed and planned implants. Three plans were evaluated per case: clinically placed implant (HI-place), HI-planned implant (HI-plan), and AI-planned implant (AI). Evaluations included angular deviation relative to adjacent teeth and prosthetic wax-ups, vertical and horizontal bone thickness, proximity to vital structures, implant dimensions, planning time, and planning repeatability.</p><p><strong>Results: </strong>The Friedman test indicated no significant differences in implant location among the 3 approaches (P > .05). Angular deviations were similar across methods for both the neighboring tooth (HI-place = 7.01 ± 4.7°; HI-plan = 7.30 ± 5.6°; AI = 6.86 ± 3.7°) and the wax-up (HI-place = 5.22 ± 3.0°; HI-plan = 4.55 ± 3.0°; AI = 5.50 ± 4.9°). Implant diameter and length selections also did not differ significantly across HI-place (4.06 ± 0.4 mm; 10.61 ± 1.4 mm), HI-plan (4.06 ± 0.4 mm; 10.45 ± 1.4 mm), and AI (4.05 ± 0.5 mm; 10.39 ± 1.4 mm). AI was significantly faster (P < .05), requiring 150 s vs 429 s for HI-plan, and showed excellent repeatability with zero deviation between repeated plans.</p><p><strong>Conclusions: </strong>AI-driven virtual implant planning achieved clinically acceptable placement comparable to expert clinicians in single-implant rehabilitation, with superior efficiency and repeatability, supporting its use in routine presurgical workflows.</p><p><strong>Advances in knowledge: </strong>Integrating AI for implant location and dimensions selection, with accuracy comparable to expert clinicians, can streamline the digital implant workflow, reduce planning time, and allow clinicians to focus on verifying the AI-generated plan prior to clinical transfer, thereby increasing the time available for the actual treatment procedure.</p>","PeriodicalId":11261,"journal":{"name":"Dento maxillo facial radiology","volume":" ","pages":"421-430"},"PeriodicalIF":4.0000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13317984/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dento maxillo facial radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/dmfr/twag015","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: This study evaluated a validated artificial intelligence (AI) tool for virtual implant planning by comparing its performance with expert-planned and clinically placed implants in single-tooth rehabilitation cases.
Methods: Pre- and postoperative cone-beam CT (CBCT) scans were retrospectively collected from 32 single-tooth implant cases. Actual implants were placed by expert clinicians using a human intelligence (HI)-based approach guided by the preoperative CBCT. The same scans were used to generate both AI- and HI-based virtual implant plans. Pre- and postoperative scans were registered to allow accurate comparison between placed and planned implants. Three plans were evaluated per case: clinically placed implant (HI-place), HI-planned implant (HI-plan), and AI-planned implant (AI). Evaluations included angular deviation relative to adjacent teeth and prosthetic wax-ups, vertical and horizontal bone thickness, proximity to vital structures, implant dimensions, planning time, and planning repeatability.
Results: The Friedman test indicated no significant differences in implant location among the 3 approaches (P > .05). Angular deviations were similar across methods for both the neighboring tooth (HI-place = 7.01 ± 4.7°; HI-plan = 7.30 ± 5.6°; AI = 6.86 ± 3.7°) and the wax-up (HI-place = 5.22 ± 3.0°; HI-plan = 4.55 ± 3.0°; AI = 5.50 ± 4.9°). Implant diameter and length selections also did not differ significantly across HI-place (4.06 ± 0.4 mm; 10.61 ± 1.4 mm), HI-plan (4.06 ± 0.4 mm; 10.45 ± 1.4 mm), and AI (4.05 ± 0.5 mm; 10.39 ± 1.4 mm). AI was significantly faster (P < .05), requiring 150 s vs 429 s for HI-plan, and showed excellent repeatability with zero deviation between repeated plans.
Conclusions: AI-driven virtual implant planning achieved clinically acceptable placement comparable to expert clinicians in single-implant rehabilitation, with superior efficiency and repeatability, supporting its use in routine presurgical workflows.
Advances in knowledge: Integrating AI for implant location and dimensions selection, with accuracy comparable to expert clinicians, can streamline the digital implant workflow, reduce planning time, and allow clinicians to focus on verifying the AI-generated plan prior to clinical transfer, thereby increasing the time available for the actual treatment procedure.
期刊介绍:
Dentomaxillofacial Radiology (DMFR) is the journal of the International Association of Dentomaxillofacial Radiology (IADMFR) and covers the closely related fields of oral radiology and head and neck imaging.
Established in 1972, DMFR is a key resource keeping dentists, radiologists and clinicians and scientists with an interest in Head and Neck imaging abreast of important research and developments in oral and maxillofacial radiology.
The DMFR editorial board features a panel of international experts including Editor-in-Chief Professor Ralf Schulze. Our editorial board provide their expertise and guidance in shaping the content and direction of the journal.
Quick Facts:
- 2015 Impact Factor - 1.919
- Receipt to first decision - average of 3 weeks
- Acceptance to online publication - average of 3 weeks
- Open access option
- ISSN: 0250-832X
- eISSN: 1476-542X