Analysis of Trace Rare Earth Elements in Uranium-Bearing Nuclear Materials

IF 3.4 4区 工程技术 Q2 ENGINEERING, CHEMICAL
Processes Pub Date : 2025-09-26 DOI:10.3390/pr13103089
Z.-L. Li, Yang Shao, Frances Xin, Chun Li, Jilong Zhang, Xi Li, Min Luo, Diandou Xu, Lingling Ma
{"title":"Analysis of Trace Rare Earth Elements in Uranium-Bearing Nuclear Materials","authors":"Z.-L. Li, Yang Shao, Frances Xin, Chun Li, Jilong Zhang, Xi Li, Min Luo, Diandou Xu, Lingling Ma","doi":"10.3390/pr13103089","DOIUrl":null,"url":null,"abstract":"Rare earth elements (REEs) have significant application value in the quality control of nuclear materials and in traceability research in nuclear forensics. Methods were developed for the determination of REEs in uranium-bearing nuclear materials. The digestion parameters for uranium oxides and uranium ores, such as the digestion acid, digestion temperature, and digestion time, were optimized and reported. The optimized digestion parameters for uranium oxides were 2 mL HNO3 at 160 °C for 3 h, and those for uranium ores were 7 mL mixed acid (HNO3–HClO4–HF = 5:5:3) at 180 °C for 36 h. Two digestion methods were demonstrated to be effective for the quantitative recovery of REEs. The suitable system and specifications for different resin columns were investigated to achieve a high decontamination factor of U (105) by UTEVA resin. The corresponding loading system was 10 mL 4 M HNO3, and the elution system was 6 mL 4 M HNO3. Additionally, the analysis of ultra-trace REEs in high-uranium matrices was accomplished using two UTEVA resins. The developed methods were subjected to the Cochran test and the Grubbs test, and the relative standard deviation (RSD) for all REEs was below 6%. In uranium oxide samples with different spiked amounts, the recovery of REEs exceeded 80% in all cases, and the RSDs were all less than 10%. The method’s detection limits were below 10 ppt for all REEs (except for Ce), ensuring the accurate measurement of REEs in uranium-bearing nuclear materials.","PeriodicalId":20597,"journal":{"name":"Processes","volume":"13 10","pages":"3089-3089"},"PeriodicalIF":3.4000,"publicationDate":"2025-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.mdpi.com/2227-9717/13/10/3089/pdf?version=1758900194","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Processes","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.3390/pr13103089","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Rare earth elements (REEs) have significant application value in the quality control of nuclear materials and in traceability research in nuclear forensics. Methods were developed for the determination of REEs in uranium-bearing nuclear materials. The digestion parameters for uranium oxides and uranium ores, such as the digestion acid, digestion temperature, and digestion time, were optimized and reported. The optimized digestion parameters for uranium oxides were 2 mL HNO3 at 160 °C for 3 h, and those for uranium ores were 7 mL mixed acid (HNO3–HClO4–HF = 5:5:3) at 180 °C for 36 h. Two digestion methods were demonstrated to be effective for the quantitative recovery of REEs. The suitable system and specifications for different resin columns were investigated to achieve a high decontamination factor of U (105) by UTEVA resin. The corresponding loading system was 10 mL 4 M HNO3, and the elution system was 6 mL 4 M HNO3. Additionally, the analysis of ultra-trace REEs in high-uranium matrices was accomplished using two UTEVA resins. The developed methods were subjected to the Cochran test and the Grubbs test, and the relative standard deviation (RSD) for all REEs was below 6%. In uranium oxide samples with different spiked amounts, the recovery of REEs exceeded 80% in all cases, and the RSDs were all less than 10%. The method’s detection limits were below 10 ppt for all REEs (except for Ce), ensuring the accurate measurement of REEs in uranium-bearing nuclear materials.
含铀核材料中微量稀土元素的分析
稀土元素在核材料质量控制和核法医溯源研究中具有重要的应用价值。建立了含铀核材料中稀土元素的测定方法。对铀氧化物和铀矿石的溶出酸、溶出温度、溶出时间等参数进行了优化并进行了报道。优化的溶出铀氧化物的参数为2ml HNO3在160℃下溶出3 h,铀矿石的溶出参数为7ml混合酸(HNO3 - hclo4 - hf = 5:5:3)在180℃下溶出36 h。两种溶出方法均能有效地定量回收稀土。为使UTEVA树脂达到高的去污系数U(105),研究了不同树脂柱的合适体系和规格。相应的上样体系为10 mL 4 M HNO3,洗脱体系为6 mL 4 M HNO3。此外,用两种UTEVA树脂对高铀基质中的超痕量稀土元素进行了分析。所建立的方法经Cochran检验和Grubbs检验,所有稀土元素的相对标准偏差(RSD)均在6%以下。在不同加标量的氧化铀样品中,稀土元素的回收率均大于80%,rsd均小于10%。该方法对除Ce外的所有稀土元素的检出限均在10ppt以下,保证了对含铀核材料中稀土元素的准确测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Processes
Processes Chemical Engineering-Bioengineering
CiteScore
5.10
自引率
11.40%
发文量
2239
审稿时长
14.11 days
期刊介绍: Processes (ISSN 2227-9717) provides an advanced forum for process related research in chemistry, biology and allied engineering fields. The journal publishes regular research papers, communications, letters, short notes and reviews. Our aim is to encourage researchers to publish their experimental, theoretical and computational results in as much detail as necessary. There is no restriction on paper length or number of figures and tables.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书