Impact of Catheter Configuration on the Mapping of Atrial Fibrillation.

IF 9.3 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Miguel Rodrigo, Samuel Ruipérez-Campillo, Prasanth Ganesan, Ruibin Feng, Sanjiv M Narayan
{"title":"Impact of Catheter Configuration on the Mapping of Atrial Fibrillation.","authors":"Miguel Rodrigo, Samuel Ruipérez-Campillo, Prasanth Ganesan, Ruibin Feng, Sanjiv M Narayan","doi":"10.1161/CIRCEP.125.014061","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Mapping of heart rhythms is influenced by the size and configuration of the mapping electrodes. Whether a recorded electrogram represents near (local) or remote activity influences diagnosis and treatment, yet is affected by mapping characteristics that are often undefined.</p><p><strong>Methods: </strong>We developed biophysical computational models to predict interactions between the recording tool and cardiac tissue in coherent and disorganized rhythms, which we validated in clinical recordings.</p><p><strong>Results: </strong>Biophysical computational models demonstrated the ability to quantify and visualize the recording antennae for different electrode configurations. Our results show that unipolar electrograms reflected a recording antenna within 3-dimensional ellipsoids of radius 8 mm across-tissue and 2.7 mm transmurally. Bipolar electrogram antennae align with propagation direction in ellipsoids of long axis radius 1.7, 5.7, and 8.3 mm for 2, 5, and 10 mm spacing, respectively, and often extend beyond the physical extent of electrodes. Notably, omnipolar electrograms, constructed from orthogonal bipoles in a triangular configuration, retained some directional preferences of bipolar electrograms, with a complex relationship between electrode orientation and wave direction. When tested clinically on high-resolution, narrow field (grid) catheters and moderate-to-low resolution, global (basket) catheters, antennae varied more with electrode type (correlation coefficient of 0.43 unipolar, 0.05 bipolar, and 0.26 omnipolar; <i>P</i><0.001) and spacing (correlation coefficient of 0.36 versus 0.42; <i>P</i>=0.002) than the precise electrode size.</p><p><strong>Conclusions: </strong>This novel computational-clinical system approach enabled us to systematically compare electrode configurations. This work may help interpret signals in complex biological rhythms, such as atrial fibrillation, and may influence the design of novel catheter configurations and signal processing approaches to identify local tissue signals.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e014061"},"PeriodicalIF":9.3000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13064552/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.125.014061","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Mapping of heart rhythms is influenced by the size and configuration of the mapping electrodes. Whether a recorded electrogram represents near (local) or remote activity influences diagnosis and treatment, yet is affected by mapping characteristics that are often undefined.

Methods: We developed biophysical computational models to predict interactions between the recording tool and cardiac tissue in coherent and disorganized rhythms, which we validated in clinical recordings.

Results: Biophysical computational models demonstrated the ability to quantify and visualize the recording antennae for different electrode configurations. Our results show that unipolar electrograms reflected a recording antenna within 3-dimensional ellipsoids of radius 8 mm across-tissue and 2.7 mm transmurally. Bipolar electrogram antennae align with propagation direction in ellipsoids of long axis radius 1.7, 5.7, and 8.3 mm for 2, 5, and 10 mm spacing, respectively, and often extend beyond the physical extent of electrodes. Notably, omnipolar electrograms, constructed from orthogonal bipoles in a triangular configuration, retained some directional preferences of bipolar electrograms, with a complex relationship between electrode orientation and wave direction. When tested clinically on high-resolution, narrow field (grid) catheters and moderate-to-low resolution, global (basket) catheters, antennae varied more with electrode type (correlation coefficient of 0.43 unipolar, 0.05 bipolar, and 0.26 omnipolar; P<0.001) and spacing (correlation coefficient of 0.36 versus 0.42; P=0.002) than the precise electrode size.

Conclusions: This novel computational-clinical system approach enabled us to systematically compare electrode configurations. This work may help interpret signals in complex biological rhythms, such as atrial fibrillation, and may influence the design of novel catheter configurations and signal processing approaches to identify local tissue signals.

导管配置对房颤定位的影响。
背景:心律的绘制受绘制电极的大小和结构的影响。记录的电图是否代表近(局部)或远的活动影响诊断和治疗,但往往受到未定义的映射特征的影响。方法:我们开发了生物物理计算模型来预测记录工具和心脏组织在连贯和无序节奏下的相互作用,我们在临床记录中验证了这一点。结果:生物物理计算模型证明了量化和可视化不同电极配置的记录天线的能力。结果表明,单极电图在横向半径为8 mm、横向半径为2.7 mm的三维椭球内反射了一个记录天线。双极电图天线在长轴半径为1.7、5.7和8.3 mm的椭球体中沿传播方向排列,分别为2、5和10 mm间距,并且经常延伸到电极的物理范围之外。值得注意的是,由正交双极构成三角形结构的全极电图保留了双极电图的一些方向偏好,电极取向和波方向之间存在复杂的关系。在临床上对高分辨率窄场(网格)导管和中低分辨率全局(篮状)导管进行测试时,天线与电极类型(相关系数为0.43单极、0.05双极和0.26全极;PP=0.002)的差异大于精确电极尺寸。结论:这种新颖的计算-临床系统方法使我们能够系统地比较电极配置。这项工作可能有助于解释复杂生物节律中的信号,如心房颤动,并可能影响新型导管配置的设计和信号处理方法,以识别局部组织信号。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
13.70
自引率
4.80%
发文量
187
审稿时长
4-8 weeks
期刊介绍: Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书