Integrated Primary-Secondary Distribution System State Estimation With Bimodal Error Distribution

IF 8.7 1区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
IEEE Transactions on Power Systems Pub Date : 2026-07-01 Epub Date: 2026-02-24 DOI:10.1109/TPWRS.2026.3667487
Surendra Bajagain;Anamika Dubey
{"title":"Integrated Primary-Secondary Distribution System State Estimation With Bimodal Error Distribution","authors":"Surendra Bajagain;Anamika Dubey","doi":"10.1109/TPWRS.2026.3667487","DOIUrl":null,"url":null,"abstract":"Traditionally, measurement errors are assumed to follow Gaussian distribution in the state estimation process. However, statistical analysis of field measurements has shown that measurement errors can have multimodal and skewed distribution. This work aims to develop a static power distribution system state estimator that can capture skewed bimodal measurement error distribution and enable a joint medium-voltage (MV) primary feeders and low-voltage (LV) secondary feeders state estimation. A distributed primary-secondary (MV-LV) state estimation algorithm is proposed and iteratively executed until convergence at the MV-LV boundary. The primary state estimator is formulated as an equality-constrained maximum likelihood estimation problem and the secondary state estimator is formulated as a forward-backward sweep power flow problem. The proposed algorithm is demonstrated using the IEEE 123 bus distribution test feeder modified to include secondary network extensions at 47 different nodes. The simulation results show that the state estimation results are improved by considering skewed bimodal distribution for measurement errors, the performance of the state estimator with the approximate secondary model is highly sensitive to unbalanced loadings of the split-phase customer and the convergence speed of the joint MV-LV state estimation process is improved by collecting all the legs active and reactive power demands of the split-phase customer in LV feeders.","PeriodicalId":13373,"journal":{"name":"IEEE Transactions on Power Systems","volume":"41 4","pages":"2655-2666"},"PeriodicalIF":8.7000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Power Systems","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11408920/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Traditionally, measurement errors are assumed to follow Gaussian distribution in the state estimation process. However, statistical analysis of field measurements has shown that measurement errors can have multimodal and skewed distribution. This work aims to develop a static power distribution system state estimator that can capture skewed bimodal measurement error distribution and enable a joint medium-voltage (MV) primary feeders and low-voltage (LV) secondary feeders state estimation. A distributed primary-secondary (MV-LV) state estimation algorithm is proposed and iteratively executed until convergence at the MV-LV boundary. The primary state estimator is formulated as an equality-constrained maximum likelihood estimation problem and the secondary state estimator is formulated as a forward-backward sweep power flow problem. The proposed algorithm is demonstrated using the IEEE 123 bus distribution test feeder modified to include secondary network extensions at 47 different nodes. The simulation results show that the state estimation results are improved by considering skewed bimodal distribution for measurement errors, the performance of the state estimator with the approximate secondary model is highly sensitive to unbalanced loadings of the split-phase customer and the convergence speed of the joint MV-LV state estimation process is improved by collecting all the legs active and reactive power demands of the split-phase customer in LV feeders.
基于双峰误差分布的综合主次配电系统状态估计
传统上,在状态估计过程中假定测量误差服从高斯分布。然而,实测数据的统计分析表明,测量误差具有多模态分布和偏态分布。本工作旨在开发一种静态配电系统状态估计器,它可以捕获偏斜双峰测量误差分布,并实现中压(MV)一次馈线和低压(LV)二次馈线的联合状态估计。提出了一种分布式主-次状态估计算法,并迭代执行,直到在主-次状态估计边界收敛。将主状态估计量表述为一个等式约束的最大似然估计问题,将次状态估计量表述为一个前向-后向扫描潮流问题。该算法使用IEEE 123总线分布测试馈线进行了验证,该馈线经过修改,包括47个不同节点的二次网络扩展。仿真结果表明:考虑了测量误差的偏斜双峰分布,改善了状态估计结果;近似二次模型的状态估计器对分相客户的不平衡负荷高度敏感;通过收集低压馈线中分相客户的所有支路有功和无功需求,提高了MV-LV联合状态估计过程的收敛速度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Power Systems
IEEE Transactions on Power Systems 工程技术-工程:电子与电气
CiteScore
15.80
自引率
7.60%
发文量
696
审稿时长
3 months
期刊介绍: The scope of IEEE Transactions on Power Systems covers the education, analysis, operation, planning, and economics of electric generation, transmission, and distribution systems for general industrial, commercial, public, and domestic consumption, including the interaction with multi-energy carriers. The focus of this transactions is the power system from a systems viewpoint instead of components of the system. It has five (5) key areas within its scope with several technical topics within each area. These areas are: (1) Power Engineering Education, (2) Power System Analysis, Computing, and Economics, (3) Power System Dynamic Performance, (4) Power System Operations, and (5) Power System Planning and Implementation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书