Mid-Term Outcomes Following Endovascular Aneurysm Repair Using the INCRAFT Stent-Graft System.

IF 2.2 4区 医学 Q3 SURGERY
Surgical Innovation Pub Date : 2026-10-01 Epub Date: 2026-02-23 DOI:10.1177/15533506261425005
Dashuai Wang, Yuxuan Li, Shaojie Li, Ni Zhao, Yongyu Zhang, Xiufang Lv, Xiaodi Zheng, Hairun Gan, Pengfei Pang
{"title":"Mid-Term Outcomes Following Endovascular Aneurysm Repair Using the INCRAFT Stent-Graft System.","authors":"Dashuai Wang, Yuxuan Li, Shaojie Li, Ni Zhao, Yongyu Zhang, Xiufang Lv, Xiaodi Zheng, Hairun Gan, Pengfei Pang","doi":"10.1177/15533506261425005","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundThis study aims to investigate the durability and outcomes of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAAs) using the low-profile INCRAFT Stent-Graft System.MethodsBaseline characteristics, procedural data, and clinical outcomes were retrospectively collected from patients diagnosed with infrarenal AAAs, who underwent elective EVAR using the INCRAFT device from August 2017 to March 2023 at our institute.ResultsThirty-two patients with a mean age of 72.72 ± 7.18 years were included in the study, and 84.4% of the patients had hostile iliac accesses. The immediate technical success rate of INCRAFT device implantation was 100%, and clinical success was obtained in all patients post-procedure. The intraprocedural endoleak (EL) rate was 15.6%, with three cases of type 1a EL and two cases of type 1b EL (resolved after percutaneous transluminal angioplasty). Reintervention was required in 5 patients, four of whom underwent successful transarterial embolisation for type 2 EL; one of the patient underwent proximal extension for type 1a EL. During a median post-procedural follow-up of 32 months, there were no aneurysm-related deaths, stent-graft migration, or aneurysm-related ruptures. Freedom from all-cause mortality was 93.8%, and freedom from secondary intervention was 84.4% at 3 years.ConclusionsIn this real-world study setting, the midterm outcomes of the INCRAFT Stent-Graft System showed no aneurysm-related deaths. The use of this low-profile device for infrarenal AAAs is associated with sustained success and relatively low rates of reintervention during follow-up, which represents a safe and effective option for endovascular treatment in patients with hostile iliac accesses.</p>","PeriodicalId":22095,"journal":{"name":"Surgical Innovation","volume":" ","pages":"449-457"},"PeriodicalIF":2.2000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Innovation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15533506261425005","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/23 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

BackgroundThis study aims to investigate the durability and outcomes of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAAs) using the low-profile INCRAFT Stent-Graft System.MethodsBaseline characteristics, procedural data, and clinical outcomes were retrospectively collected from patients diagnosed with infrarenal AAAs, who underwent elective EVAR using the INCRAFT device from August 2017 to March 2023 at our institute.ResultsThirty-two patients with a mean age of 72.72 ± 7.18 years were included in the study, and 84.4% of the patients had hostile iliac accesses. The immediate technical success rate of INCRAFT device implantation was 100%, and clinical success was obtained in all patients post-procedure. The intraprocedural endoleak (EL) rate was 15.6%, with three cases of type 1a EL and two cases of type 1b EL (resolved after percutaneous transluminal angioplasty). Reintervention was required in 5 patients, four of whom underwent successful transarterial embolisation for type 2 EL; one of the patient underwent proximal extension for type 1a EL. During a median post-procedural follow-up of 32 months, there were no aneurysm-related deaths, stent-graft migration, or aneurysm-related ruptures. Freedom from all-cause mortality was 93.8%, and freedom from secondary intervention was 84.4% at 3 years.ConclusionsIn this real-world study setting, the midterm outcomes of the INCRAFT Stent-Graft System showed no aneurysm-related deaths. The use of this low-profile device for infrarenal AAAs is associated with sustained success and relatively low rates of reintervention during follow-up, which represents a safe and effective option for endovascular treatment in patients with hostile iliac accesses.

使用INCRAFT支架-移植物系统进行血管内动脉瘤修复的中期结果。
本研究旨在探讨采用低姿态的INCRAFT支架系统对腹主动脉瘤(AAAs)进行血管内动脉瘤修复(EVAR)的耐久性和效果。方法回顾性收集2017年8月至2023年3月在我院使用INCRAFT设备进行选择性EVAR的诊断为肾下AAAs的患者的基线特征、手术数据和临床结果。结果32例患者入组,平均年龄(72.72±7.18)岁,84.4%的患者存在不良髂通道。INCRAFT器械植入即刻技术成功率100%,所有患者术后均获得临床成功。术中漏腔率15.6%,其中1a型漏腔3例,1b型漏腔2例(经皮腔内血管成形术后消失)。5例患者需要再次干预,其中4例成功进行了经动脉栓塞治疗2型EL;1例1a型EL患者行近端伸展术。在中位术后随访32个月期间,无动脉瘤相关死亡、支架移植物迁移或动脉瘤相关破裂。3年时,无全因死亡率为93.8%,无二次干预为84.4%。结论:在真实世界的研究环境中,INCRAFT支架移植系统的中期结果显示没有动脉瘤相关的死亡。在随访期间,使用这种低姿态的装置治疗肾下动脉粥样硬化具有持续的成功和相对低的再干预率,这是髂通道不通畅患者血管内治疗的一种安全有效的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Surgical Innovation
Surgical Innovation 医学-外科
CiteScore
2.90
自引率
0.00%
发文量
72
审稿时长
6-12 weeks
期刊介绍: Surgical Innovation (SRI) is a peer-reviewed bi-monthly journal focusing on minimally invasive surgical techniques, new instruments such as laparoscopes and endoscopes, and new technologies. SRI prepares surgeons to think and work in "the operating room of the future" through learning new techniques, understanding and adapting to new technologies, maintaining surgical competencies, and applying surgical outcomes data to their practices. This journal is a member of the Committee on Publication Ethics (COPE).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书