Clinically interpretable machine-learning model for predicting heart mean dose using simple BEV-based metrics

IF 1.7 4区 医学 Q4 ONCOLOGY
Medical Dosimetry Pub Date : 2026-01-01 Epub Date: 2026-02-21 DOI:10.1016/j.meddos.2026.01.008
Sathiyaraj Palanivel Ph.D.
{"title":"Clinically interpretable machine-learning model for predicting heart mean dose using simple BEV-based metrics","authors":"Sathiyaraj Palanivel Ph.D.","doi":"10.1016/j.meddos.2026.01.008","DOIUrl":null,"url":null,"abstract":"<div><div>Radiation-induced cardiac toxicity remains a major concern in left-sided breast cancer radiotherapy, with mean heart dose (MHD) serving as a key predictor of long-term cardiac morbidity. This study aimed to develop a clinically interpretable machine-learning model to predict MHD using simple beam’s-eye-view (BEV)–based heart-projection metrics. A retrospective cohort of 127 patients treated with postoperative left breast or chest wall radiotherapy including supraclavicular nodal irradiation was analyzed. Heart projections in the lateral and vertical directions were measured from medial and lateral tangential fields, defined as medial tangential horizontal (MTH), lateral tangential horizontal (LTH), medial tangential vertical (MTV), and lateral tangential vertical (LTV). Outliers were removed using interquartile range criteria. A multivariable linear regression model was developed using 5-fold cross-validation to predict MHD. In addition, a logistic regression classifier was trained to categorize patients suitable for three-dimensional conformal radiotherapy (MHD ≤ 4 Gy) versus inverse planning (MHD &gt; 4 Gy). Model performance was evaluated using R², root mean squared error (RMSE), mean absolute error (MAE), Pearson correlation coefficient, accuracy, and area under the receiver operating characteristic curve (AUC). The linear regression model demonstrated strong predictive performance during cross-validation (R² = 0.69, RMSE = 0.61 Gy, MAE = 0.47 Gy), with a significant correlation between predicted and measured MHD (<em>r</em> = 0.83, <em>p</em> &lt; 0.001). Independent validation further improved performance (R² = 0.76, RMSE = 0.69 Gy, MAE = 0.56 Gy; <em>r</em> = 0.90, <em>p</em> &lt; 0.001). The logistic regression classifier achieved an overall accuracy of 88% with excellent discrimination (AUC = 0.95). Simple beam’s-eye-view (BEV)-based heart-projection metrics can reliably predict MHD, enabling rapid preplanning assessment and supporting early selection of cardiac-sparing radiotherapy techniques.</div></div>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":"51 3","pages":"Pages 272-277"},"PeriodicalIF":1.7000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0958394726000105","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Radiation-induced cardiac toxicity remains a major concern in left-sided breast cancer radiotherapy, with mean heart dose (MHD) serving as a key predictor of long-term cardiac morbidity. This study aimed to develop a clinically interpretable machine-learning model to predict MHD using simple beam’s-eye-view (BEV)–based heart-projection metrics. A retrospective cohort of 127 patients treated with postoperative left breast or chest wall radiotherapy including supraclavicular nodal irradiation was analyzed. Heart projections in the lateral and vertical directions were measured from medial and lateral tangential fields, defined as medial tangential horizontal (MTH), lateral tangential horizontal (LTH), medial tangential vertical (MTV), and lateral tangential vertical (LTV). Outliers were removed using interquartile range criteria. A multivariable linear regression model was developed using 5-fold cross-validation to predict MHD. In addition, a logistic regression classifier was trained to categorize patients suitable for three-dimensional conformal radiotherapy (MHD ≤ 4 Gy) versus inverse planning (MHD > 4 Gy). Model performance was evaluated using R², root mean squared error (RMSE), mean absolute error (MAE), Pearson correlation coefficient, accuracy, and area under the receiver operating characteristic curve (AUC). The linear regression model demonstrated strong predictive performance during cross-validation (R² = 0.69, RMSE = 0.61 Gy, MAE = 0.47 Gy), with a significant correlation between predicted and measured MHD (r = 0.83, p < 0.001). Independent validation further improved performance (R² = 0.76, RMSE = 0.69 Gy, MAE = 0.56 Gy; r = 0.90, p < 0.001). The logistic regression classifier achieved an overall accuracy of 88% with excellent discrimination (AUC = 0.95). Simple beam’s-eye-view (BEV)-based heart-projection metrics can reliably predict MHD, enabling rapid preplanning assessment and supporting early selection of cardiac-sparing radiotherapy techniques.
临床可解释的机器学习模型,用于使用简单的基于bev的指标预测心脏平均剂量。
辐射引起的心脏毒性仍然是左侧乳腺癌放疗的主要问题,平均心脏剂量(MHD)是长期心脏发病率的关键预测指标。本研究旨在开发一种临床可解释的机器学习模型,使用基于简单光束眼视图(BEV)的心脏投影指标来预测MHD。回顾性分析127例术后左乳或胸壁放射治疗包括锁骨上淋巴结放射治疗的患者。从内侧和外侧切向场测量心脏在横向和纵向的投影,定义为内侧切向水平(MTH)、外侧切向水平(LTH)、内侧切向垂直(MTV)和外侧切向垂直(LTV)。使用四分位数范围标准去除异常值。采用5重交叉验证建立多变量线性回归模型预测MHD。此外,训练逻辑回归分类器对适合三维适形放疗(MHD≤4 Gy)与逆计划(MHD > 4 Gy)的患者进行分类。使用R²、均方根误差(RMSE)、平均绝对误差(MAE)、Pearson相关系数、精度和受试者工作特征曲线下面积(AUC)来评估模型的性能。线性回归模型展示了强大的预测性能在交叉验证(R² = 0.69,RMSE = 0.61  Gy,梅 = 0.47 Gy),预测和测量磁流体动力之间的显著相关性(R = 0.83,p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Dosimetry
Medical Dosimetry 医学-核医学
CiteScore
2.40
自引率
0.00%
发文量
51
审稿时长
34 days
期刊介绍: Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书