{"title":"Measurement of liver volume using water delay ultrasonography.","authors":"H Baddeley,&nbsp;M Benson,&nbsp;G Liefman,&nbsp;T Singcharoen,&nbsp;V Siskind,&nbsp;K Soon,&nbsp;J Williams","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A modification of the method of Carr et al. [1976] for the ultrasonic assessment of liver volume was devised for use with a UI Octoson water delay B mode echoscope, and 32 subjects without clinical history or signs of liver disease were examined. In 9 subjects the measurements were repeated by a separate observer. Comparison of the variance between observers and that between subjects showed that the precision of the method is within acceptable limits, the variance ratio (F) being 13.7 (p less than 0.001). The mean liver volume was 1,545.4 +/- (SD) 255 ml. This finding is in close agreement with previously published data. The liver volume was correlated with body weight, height, body surface area, and body mass index. The liver volume was found to correlate best with body weight using partial correlation analysis. This was in accordance with previously published data, with the exception of that of Koischwitz [1979]. However, variations in weight could only account for 0.43 of the variation in liver volume.</p>","PeriodicalId":77706,"journal":{"name":"Diagnostic imaging in clinical medicine","volume":"55 6","pages":"330-6"},"PeriodicalIF":0.0000,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic imaging in clinical medicine","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A modification of the method of Carr et al. [1976] for the ultrasonic assessment of liver volume was devised for use with a UI Octoson water delay B mode echoscope, and 32 subjects without clinical history or signs of liver disease were examined. In 9 subjects the measurements were repeated by a separate observer. Comparison of the variance between observers and that between subjects showed that the precision of the method is within acceptable limits, the variance ratio (F) being 13.7 (p less than 0.001). The mean liver volume was 1,545.4 +/- (SD) 255 ml. This finding is in close agreement with previously published data. The liver volume was correlated with body weight, height, body surface area, and body mass index. The liver volume was found to correlate best with body weight using partial correlation analysis. This was in accordance with previously published data, with the exception of that of Koischwitz [1979]. However, variations in weight could only account for 0.43 of the variation in liver volume.

水延迟超声测量肝脏体积。
对Carr等[1976]超声评估肝脏体积的方法进行了改进,设计了一种使用UI Octoson水延迟B型超声的方法,对32名无临床病史或肝脏疾病症状的受试者进行了检查。在9名受试者中,由单独的观察者重复测量。观察者与受试者之间的方差比较表明,该方法的精度在可接受范围内,方差比(F)为13.7 (p < 0.001)。平均肝脏体积为1,545.4 +/- (SD) 255 ml。这一发现与先前发表的数据非常一致。肝体积与体重、身高、体表面积、体质指数相关。用偏相关分析发现肝脏体积与体重的相关性最好。这与以前发表的数据一致,Koischwitz[1979]的数据除外。然而,体重变化只能解释肝脏体积变化的0.43。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信