[Myocardial perfusion imaging by digital subtraction angiography].

Journal of cardiography Pub Date : 1986-03-01
H Kadowaki, K Ishikawa, T Ogai, R Katori
{"title":"[Myocardial perfusion imaging by digital subtraction angiography].","authors":"H Kadowaki,&nbsp;K Ishikawa,&nbsp;T Ogai,&nbsp;R Katori","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":77734,"journal":{"name":"Journal of cardiography","volume":"16 1","pages":"11-7"},"PeriodicalIF":0.0000,"publicationDate":"1986-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiography","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

[数字减影血管造影心肌灌注成像]。
本文对7例心肌梗死患者、2例心绞痛患者和5例冠状动脉正常患者的数字减影血管造影(DSA)方法进行比较,以确定哪种冠状动脉造影能更好地显示局部心肌灌注。如果掩膜上心脏的形状与活体膜上的形状相同,并且两种膜完全重叠,则判断达到满意的DSA。为了获得与每个活膜形状相同的掩膜,从心脏周期的以下三个阶段中选择两个膜;在心电图R波前100毫秒,在R波前200毫秒。由于这两个阶段的心脏运动相对较小,因此在获得形状相似的掩膜和活膜方面,后两个阶段的优势更大。使用这些掩膜和活膜,分别用连续图像模式(CI模式)或时间间隔差模式(TID模式)进行DSA。通过CI模式充分显示造影剂经动脉至静脉的整体灌注情况。在每个阶段用TID模式显示造影剂通过动脉、毛细血管和静脉的情况。显示并拍摄减影图像,对比介质的密度足以显示等高线,就像在地形图中一样。使用这种DSA,我们发现造影剂的区域灌注在正常受试者中并不总是均匀的,这取决于冠状动脉的类型。(摘要删节250字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信